System Overview
This Goodman 3.5 Ton Central Heat Pump Split System pairs the GZV6SA4210 high-efficiency, variable-speed, inverter-driven R-32 heat pump with the AHVE60DP1300 Multi-Position Air Handler. Rated at 17.0 SEER2 and 8.2 HSPF2, this AHRI-certified combination (Certificate #215429790) delivers all-electric heating and cooling with the air handler providing the indoor blower, evaporator coil, and EEV in a single integrated cabinet. The AHVE-series air handler features a variable-speed ECM blower motor with communicating capability, a 21" cabinet depth for easier attic access, and all-aluminum evaporator coil construction optimized for R-32 refrigerant.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
What's Included
- GZV6SA4210 — Goodman GZV6S-Series 3.5 Ton R-32 Inverter-Driven Variable-Speed Heat Pump Condenser (Side Discharge). Rated for 41,000 BTU/h cooling at 95°F and 40,000 BTU/h heating at 47°F.
- AHVE60DP1300 — Goodman AHVE-Series Multi-Position Variable-Speed Air Handler with internal EEV, 24-1/2" cabinet width, 21" depth. 208-230V/1Ph/60Hz electrical. Factory-installed R-32 sensor. 1 HP ECM blower motor. Ships at 167 lbs.
Pro-Installer Tip
The Technical Friction: The AHVE air handler's 21" depth makes it a strong choice for tight attic installations, but the 58" overall height means you need sufficient vertical clearance above the unit for the supply plenum transition. In horizontal attic applications, verify that the truss spacing and attic height accommodate both the air handler dimensions and the required clearances to combustible materials.
The Long-Term Prevention: The AHVE's SmartFrame™ cabinet uses screw-less sides and back panels, which reduces condensation points in humid attic environments. However, verify that the foil-faced insulation is fully intact after positioning—even small gaps in the cabinet insulation can create condensation drip points that corrode the drain pan over time. Apply UL-listed aluminum foil tape over any insulation seams disrupted during installation.
The Expert Validation: After completing refrigerant line connections, run the communicating setup procedure through the Goodman GTST connected thermostat or CoolCloud™ app. The system should auto-detect the air handler model and configure airflow tables automatically. Verify the CFM indicator on the air handler reads within ±5% of the target 1,400 CFM (400 CFM/ton × 3.5 tons) at the design static pressure.
The Professional Standard: R-32 systems with the AHVE air handler include a factory-installed R-32 refrigerant sensor. Confirm the sensor LED indicator shows active status before closing up the equipment closet or attic access. Per UL 60335 2-40, the sensor must remain unobstructed for the life of the system. All R-32 work requires EPA Section 608 certification.
Key Benefits
- Integrated System Design: The AHVE air handler combines evaporator coil, blower, EEV, and control board in a single matched cabinet, eliminating field-installed coil positioning, separate TXV/piston kits, and multi-component wiring.
- Variable-Speed Comfort: Both the outdoor compressor and indoor blower operate on variable-speed ECM motors, synchronizing airflow and refrigerant flow for optimal humidity control and consistent room temperatures across all load conditions.
- R-32 Environmental Advantage: R-32 refrigerant carries a GWP of 675—approximately 68% lower than R-410A. The factory-installed R-32 sensor in the air handler provides continuous monitoring per UL 60335 2-40 safety requirements.
- Attic-Friendly Dimensions: The 21" cabinet depth fits standard attic truss spacing, and tool-less filter access simplifies homeowner maintenance. The SmartFrame™ construction with screw-less sides minimizes condensation entry points.
- Communicating Architecture: Two-wire communicating connection between outdoor unit and air handler enables automatic configuration, real-time performance monitoring, and Bluetooth-accessible diagnostics via CoolCloud™.
- Quiet Operation: Outdoor unit quiet-mode reduces sound to as low as 45 dBA, while the variable-speed indoor blower ramps gradually to avoid the abrupt on/off noise of single-speed systems.
Technical Specifications
| Specification | Detail |
|---|---|
| AHRI Certificate Number | 215429790 |
| System Type | Central Heat Pump Split System |
| System Capacity | 3.5 Ton (42,000 BTU nominal) |
| SEER2 | 17.0 |
| HSPF2 | 8.2 |
| Refrigerant | R-32 |
| Heat Pump Cooling Capacity | 41,000 BTU/h @ 95°F |
| Heat Pump Heating Capacity | 40,000 BTU/h @ 47°F |
| Heat Pump Heating Capacity (Low Temp) | 27,400 BTU/h @ 5°F |
| Outdoor Unit Dimensions (WxDxH) | 37" x 12-5/8" x 39" |
| Outdoor Unit Weight | 185 lbs (shipping) |
| Air Handler Cabinet Width | 24-1/2" |
| Air Handler Depth | 21" |
| Air Handler Height | 58" |
| Air Handler Weight | 167 lbs (shipping) |
| Electrical (Outdoor) | 208-230V / 1 Phase / 60 Hz |
| Electrical (Air Handler) | 208-230V/1Ph/60Hz |
| MCA / MOCP (Outdoor) | 31.8A / 35A |
| MCA / MOCP (Air Handler) | 6.8A / 15A |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Category | Detail |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Refrigerant GWP | 675 (vs. 2,088 for R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 | Certified technician required for refrigerant handling |
| Regional Compliance | All Regions (verify local A2L adoption status) |
| AHRI Certified | Yes — Certificate #215429790 |
| Energy Star Certified | No |
| Federal Tax Credit Eligibility | Systems meeting applicable efficiency thresholds may qualify under 25C/25D credits. Consult a tax professional and visit goodmanmfg.com/resources/tax-credit for current guidance. |
Warranty & Registration
- GZV6SA4210 (Outdoor Heat Pump): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.
- AHVE60DP1300 (Air Handler): 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.
Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida. Refer to the manufacturer's full warranty documentation for complete terms, limitations, and exclusions.