Goodman | 3.5 Ton | 17.0 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil & Modular Blower | GZV6SA4210 + CHPEA4830C3 + MBVK16CP1X00 | 21" Cabinet Width | Horizontal | Coil | 21" Cabinet Width | Multi-Positional | Modular Blower

SKU: GZV6SA4210-CHPEA4830C3-MBVK16CP1X00
Your Price:
$5,532.00 $7,302.00
You Save: $1,770.00 25%
Checkout Secure

Quantity Remaining:

475 of 500 Sold
Order in the next to get it by

System Overview

This Goodman 3.5 Ton Central Heat Pump Split System with Evaporator Coil & Modular Blower pairs the GZV6SA4210 high-efficiency, variable-speed, inverter-driven R-32 heat pump with the CHPEA4830C3 Cased Horizontal Evaporator Coil and MBVK16CP1X00 Modular Blower. Rated at 17.0 SEER2 and 7.5 HSPF2, this AHRI-certified combination (Certificate #215447226) delivers all-electric heating and cooling. The modular blower provides the air distribution component where no furnace or integrated air handler is used, creating a complete split system with separate, field-matched coil and blower sections. This configuration is optimized for R-32 refrigerant with a GWP of 675.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

What's Included

  • GZV6SA4210 — Goodman GZV6S-Series 3.5 Ton R-32 Inverter-Driven Variable-Speed Heat Pump Condenser (Side Discharge). Rated for 41,000 BTU/h cooling at 95°F and 40,000 BTU/h heating at 47°F.
  • CHPEA4830C3 — Goodman Cased Horizontal Evaporator Coil with 30" cabinet width, 21" depth, and 21" height. All-aluminum 7mm tube construction with EEV compatibility. Ships at 76 lbs.
  • MBVK16CP1X00 — Goodman MBVK-Series Multi-Positional Modular Blower with 3/4 HP variable-speed ECM motor. Cabinet dimensions: 21" W x 21" D x 30" H. 208/230V electrical. Ships at 80 lbs.

Pro-Installer Tip

The Technical Friction: Modular blower-to-coil joints require a precise seal to prevent conditioned air bypass and condensation leaks. The 21" blower must align flush with the 30" coil section—any mismatch in cabinet widths requires a factory filler plate kit (Goodman part FPKT01). In high-humidity environments, the coil-to-blower junction is the primary condensation failure point if not properly sealed.

The Long-Term Prevention: Apply the factory-provided gasket (part 0154D20003S) at the coil-blower joint, and verify the drain pan is properly pitched toward the primary drain connection. For horizontal installations in unconditioned attic spaces, install the optional condensate management kit (MBK0002) to address secondary condensation that forms on the blower cabinet exterior during peak cooling. This prevents water staining and mold growth on ceiling drywall below—a common callback 6–12 months post-install.

The Expert Validation: After completing all refrigerant connections, verify system subcooling at 8±1°F with a digital manifold gauge set. Use the CoolCloud™ app or GTST thermostat to confirm the communicating bus has established connection between the outdoor unit, coil EEV, and blower motor controller. Verify airflow at the blower outlet with an anemometer or flow hood, targeting 1,400 CFM ±10% for this 3.5-ton system.

The Professional Standard: R-32 refrigerant is classified A2L (mildly flammable) under ASHRAE 34. The R-32 accessory kit (part 0230K00044) is required if the modular blower is not factory-rated for A2L refrigerants. Verify local code adoption of 2024 UMC/IMC A2L provisions. All R-32 work requires EPA Section 608 certification.

Key Benefits

  • Modular Flexibility: The separate coil + blower configuration allows independent component replacement and sizing, providing installers more flexibility in tight mechanical rooms, closets, or horizontal attic installations where integrated air handlers may not fit.
  • Variable-Speed Comfort: The inverter-driven outdoor compressor and ECM blower motor work together to modulate airflow and refrigerant flow for optimal humidity control, consistent temperatures, and reduced energy consumption during part-load conditions.
  • R-32 Environmental Advantage: R-32 refrigerant carries a GWP of 675—approximately 68% lower than R-410A—reducing the carbon footprint of the refrigeration cycle over the entire system service life.
  • All-Electric Operation: No gas piping, venting, or combustion air requirements simplify permitting and installation while eliminating combustion byproducts from the conditioned space.
  • Quiet Operation: Outdoor unit quiet-mode reduces sound to as low as 45 dBA with three selectable levels. The variable-speed indoor blower ramps gradually to minimize duct noise and pressure surges.

Technical Specifications

Specification Detail
AHRI Certificate Number 215447226
System Type Central Heat Pump Split System with Evaporator Coil & Modular Blower
System Capacity 3.5 Ton (42,000 BTU nominal)
SEER2 17.0
HSPF2 7.5
Refrigerant R-32
Heat Pump Cooling Capacity 41,000 BTU/h @ 95°F
Heat Pump Heating Capacity 40,000 BTU/h @ 47°F
Heat Pump Heating Capacity (Low Temp) 27,400 BTU/h @ 5°F
Outdoor Unit Dimensions (WxDxH) 37" x 12-5/8" x 39"
Outdoor Unit Weight 185 lbs (shipping)
Coil Dimensions (WxDxH) 30" x 21" x 21"
Coil Weight 76 lbs (shipping)
Blower Dimensions (WxDxH) 21" x 21" x 30"
Blower Weight 80 lbs (shipping)
Electrical (Outdoor) 208-230V / 1 Phase / 60 Hz
Electrical (Blower) 208/230V
MCA / MOCP (Outdoor) 31.8A / 35A
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Detail
Refrigerant Type R-32 (Difluoromethane)
Refrigerant GWP 675 (vs. 2,088 for R-410A)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Certified technician required for refrigerant handling
Regional Compliance All Regions (verify local A2L adoption status)
AHRI Certified Yes — Certificate #215447226
Energy Star Certified No
Federal Tax Credit Eligibility Systems meeting applicable efficiency thresholds may qualify under 25C/25D credits. Consult a tax professional and visit goodmanmfg.com/resources/tax-credit for current guidance.

Warranty & Registration

  • GZV6SA4210 (Outdoor Heat Pump): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.
  • CHPEA4830C3 (Evaporator Coil): 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.
  • MBVK16CP1X00 (Modular Blower): 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.

Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida. Refer to the manufacturer's full warranty documentation for complete terms, limitations, and exclusions.