Goodman 4 Ton 16.7 SEER2 8.2 HSPF2 R-32 Dual Fuel System - Communicating (GZV6SA4810 | CAPEA4830D3 | GMVM971005CN) with 24½" Cabinet Width Upflow/Downflow Cased Coil and 100,000 BTU/h Upflow/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace

SKU: GZV6SA4810-CAPEA4830D3-GMVM971005CN
Your Price:
$8,110.00 $10,138.00
You Save: $2,028.00 21%
Checkout Secure

Quantity Remaining:

627 of 700 Sold
Order in the next to get it by

This AHRI-certified Goodman Dual Fuel System (AHRI Ref. No. 215488359) pairs the GZV6SA4810 4-ton variable-speed R-32 heat pump with the GMVM971005CN 97% AFUE modulating gas furnace and the CAPEA4830D3 upflow/downflow evaporator coil with full communicating capability between the outdoor unit, indoor coil, and furnace. Rated at 16.7 SEER2 and 8.2 HSPF2, this system delivers efficient year-round comfort with automatic switchover between electric heat pump and gas furnace operation based on outdoor temperature conditions.

The outdoor unit is ENERGY STAR® Most Efficient certified (Cold Climate) and uses R-32 refrigerant with a GWP of 675 — approximately 68% lower than R-410A. The system is AHRI Certified and ETL Listed.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • Outdoor Heat Pump: GZV6SA4810 — 4-ton variable-speed R-32 side-discharge heat pump with 45,500 BTU/h cooling and 45,500 BTU/h heating capacity (47°F). Features EEV metering, variable-speed swing compressor, and digitally commutated fan motor with Quiet Mode (as low as 45 dBA).
  • Evaporator Coil: CAPEA4830D3 — cased upflow/downflow evaporator coil with factory-installed EEV. All-aluminum coil optimized for R-32 refrigerant with built-in R-32 sensor. 24½"W × 21"D × 30"H, 70 lbs shipping weight.
  • Gas Furnace: GMVM971005CN — 100,000 BTU/h input (97,000 BTU/h output), 97% AFUE, upflow/horizontal modulating gas furnace with variable-speed ecm blower motor. Natural Gas rated. 21"W × 28⅞"D × 34½"H, 144 lbs shipping weight.

Pro-Installer Tip

The Technical Friction: The 97% AFUE condensing furnace requires PVC (2" - 3" PVC) intake and exhaust runs, and in retrofit applications, routing these through rim joists or soffits while maintaining proper termination clearances from windows, dryer vents, and gas meters is the primary installation challenge.

The Long-Term Prevention: Slope all horizontal PVC runs back toward the furnace at ¼" per foot minimum, and install a condensate trap with a clean-out tee. Improper condensate management is the leading cause of nuisance pressure-switch lockouts on 90%+ AFUE furnaces within the first heating season.

The Expert Validation: After commissioning, verify combustion with a digital combustion analyzer (Testo 320 or equivalent) — CO readings in the flue should be below 100 ppm air-free, and O₂ between 6.0%–9.0% for natural gas.

The Professional Standard: PVC venting must comply with the manufacturer's certified vent tables and ANSI Z21.47/CSA 2.3 requirements. In cold climates, insulate the intake pipe in unconditioned spaces to prevent condensation that can freeze and restrict combustion air supply.

Key Benefits

  • Dual Fuel Efficiency: Automatic switchover between heat pump and gas furnace operation based on outdoor temperature maximizes operating economy — using electric heat pump operation when conditions are mild and switching to gas when temperatures drop below the thermal balance point.
  • High-Efficiency Ratings: 16.7 SEER2, 8.2 HSPF2, and 97% AFUE deliver substantial energy savings versus minimum-efficiency (14.3 SEER2 / 80% AFUE) equipment.
  • Low-GWP R-32 Refrigerant: R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088), reducing direct greenhouse gas impact while also providing improved thermodynamic efficiency and lower refrigerant charge requirements.
  • Variable-Speed Comfort: The outdoor heat pump uses a variable-speed swing compressor that modulates capacity from approximately 40% to 100%, reducing temperature swings, lowering humidity, and operating at reduced sound levels during part-load conditions.
  • Communicating System Control: Full two-wire communicating integration between outdoor unit, indoor coil, and furnace enables automatic staging, fault diagnostics with six-fault recall, and optimized comfort delivery via the Goodman GTST connected thermostat.
  • Cold Climate Capability: The GZV6SA4810 heat pump operates down to -10°F in heating mode, extending heat pump runtime deeper into the heating season before gas furnace backup engages.

Technical Specifications

System Performance Ratings (AHRI Certified)
AHRI Reference Number 215488359
SEER2 16.7
EER2 8.8
HSPF2 8.2
Furnace AFUE 97%
Outdoor Unit — GZV6SA4810
Nominal Capacity 4 Ton (48,000 BTU/h)
Max. Cooling Capacity (95°F) 45,500 BTU/h
Max. Heating Capacity (47°F) 45,500 BTU/h
Max. Heating Capacity (5°F) 28,000 BTU/h
Compressor Type Variable-Speed Swing
Refrigerant / Charge R-32 / 100 oz.
Expansion Device EEV (Electronic Expansion Valve)
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 31.8A / 35A
Liquid / Suction Line ⅜" / 1⅛"
Dimensions (W × D × H) 37" × 12⅝" × 39"
Equipment / Ship Weight 168 / 185 lbs
Sound (Quiet Mode) As low as 45 dBA
Evaporator Coil — CAPEA4830D3
Configuration Upflow/Downflow — Cased
Expansion Device EEV (Electronic Expansion Valve)
Coil Material All-Aluminum
Dimensions (W × D × H) 24½" × 21" × 30"
Shipping Weight 70 lbs
Gas Furnace — GMVM971005CN
Configuration Upflow/Horizontal
Input / Output BTU/h 100,000 / 97,000
AFUE 97%
Gas Valve Modulating
Blower Motor Variable-Speed ECM
Vent Type 2" - 3" PVC
Electrical 115 VAC / 1 Phase / 60 Hz
Dimensions (W × D × H) 21" × 28⅞" × 34½"
Shipping Weight 144 lbs
NOx Rating Natural Gas
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane)
Refrigerant GWP 675 (vs. R-410A at 2,088 — 68% reduction)
Refrigerant Safety Classification ASHRAE A2L (Mildly Flammable)
EPA Section 608 Requirements EPA-certified technicians required for refrigerant handling. R-32 is subject to EPA Section 608 venting prohibition and leak repair requirements.
Regional Compliance Meets DOE 2023 regional minimum efficiency standards for all U.S. regions. ENERGY STAR® Most Efficient 2025 (Cold Climate).
Federal Tax Credit Eligibility This system may qualify for the 25C federal tax credit (up to $2,000 for qualifying heat pumps under the Inflation Reduction Act) — consult a tax professional for individual eligibility.
AHRI Certification AHRI Certified — Reference No. 215488359
Safety Listing ETL Listed
Florida Building Code When properly anchored, the outdoor unit meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds.

Warranty & Registration

  • Outdoor Heat Pump (GZV6SA4810): Unregistered — 5-Year Parts Limited Warranty. Registered (within 60 days of installation at goodmanmfg.com) — 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (compressor failure results in full outdoor unit replacement, one time). Registration extends coverage for as long as the original owner resides in the home, up to 10 years from installation.
  • Evaporator Coil (CAPEA4830D3): Unregistered — 5-Year Parts Limited Warranty. Registered (within 60 days of installation at goodmanmfg.com) — 10-Year Parts Limited Warranty for as long as the original registered owner resides in the home.
  • Gas Furnace (GMVM971005CN): Unregistered — 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty. Registered (within 60 days of installation at goodmanmfg.com) — Heat exchanger warranty provides unit replacement for the first 10 years (if heat exchanger fails, entire furnace is replaced once); replacement heat exchanger coverage for years 11–20; and a one-time replacement heat exchanger for years 21–99. All other parts are covered for 10 years when registered. Registration extends coverage for as long as the original owner resides in the home.

Online registration is not required in California, Florida, or Québec. Warranty duration may vary in Texas and Florida. All warranties cover parts only — labor, freight, and refrigerant are not included. Units must be installed by a licensed contractor in accordance with applicable codes. Complete warranty details are available at goodmanmfg.com.