Goodman | 4 Ton | 17.0 SEER2 | R-32 | Dual Fuel System | GZV6SA4810A | CAPEA4830D3 | GRVT800805DN | 24-1/2" Cabinet Width | Upflow/Downflow | Cased Coil | 80,000 BTU | 80% AFUE | Upflow/Horizontal | Two-Stage | Variable-Speed ECM | Furnace

SKU: GZV6SA4810A-CAPEA4830D3-GRVT800805DN
Your Price:
$7,192.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

This Goodman Dual Fuel System pairs the GZV6SA4810A 4-ton variable-speed inverter-driven R-32 heat pump condenser with the CAPEA4830D3 upflow/downflow cased evaporator coil and the GRVT800805DN 80% AFUE two-stage gas furnace. Rated at 17.0 SEER2 and 8.2 HSPF2 under AHRI Certificate #215487326, this matched system delivers variable-speed heat pump cooling and heating with gas furnace backup for sustained comfort in all climate conditions. The system uses R-32 refrigerant (GWP 675), a next-generation low-GWP alternative to R-410A that supports improved thermodynamic efficiency and reduced environmental impact.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • Outdoor Condensing Unit: Goodman GZV6SA4810A — 4-ton variable-speed inverter-driven R-32 heat pump with side-discharge cabinet, swing compressor, and EEV metering. Cold Climate rated with quiet-mode operation (as low as 45 dBA).
  • Indoor Evaporator Coil: Goodman CAPEA4830D3 — Upflow/Downflow cased all-aluminum evaporator coil with factory-installed EEV, 24-1/2" cabinet width, and R-32-optimized circuitry. 21" depth for easier attic/closet access.
  • Gas Furnace: Goodman GRVT800805DN — 80,000 BTU/h input / 64,000 BTU/h output, 80% AFUE, two-stage gas valve, variable-speed ecm blower motor, upflow/horizontal configuration.

Pro-Installer Tip: When pairing the GZV6SA4810A variable-speed heat pump with the GRVT800805DN 80% AFUE furnace, verify the single-wall metal flue vent meets Category I venting requirements per NFPA 54 clearances — this 80% AFUE unit requires proper draft conditions that can be compromised in tight mechanical closets. Set the changeover point (balance point) between heat pump and gas furnace operation based on local fuel costs and climate data; in most regions, the crossover falls between 30-35°F outdoor temperature. Use a digital manometer to verify gas manifold pressure at both high and low fire (if two-stage) — confirming ±0.3" W.C. of spec prevents short-cycling and nuisance lockouts that typically surface during the first cold snap. Check local codes for any requirements regarding combustion air openings to the mechanical room, as this directly impacts safe furnace operation.

Key Benefits

  • Variable-Speed Inverter Efficiency: The GZV6SA4810A uses variable-speed swing compressor technology to ramp output up or down based on demand, achieving up to 17.0 SEER2 and 8.2 HSPF2 — reducing energy consumption compared to single-stage systems that cycle between full-on and full-off.
  • R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). R-32 also provides approximately 10% higher volumetric capacity than R-410A, enabling smaller compressor displacements for equivalent cooling output.
  • Quiet-Mode Operation: The outdoor unit features three selectable quiet-mode levels that reduce sound output to as low as 45 dBA sound pressure at 3 feet — approaching background noise levels for residential neighborhoods and suitable for installations near bedrooms or property lines.
  • EEV-Matched Indoor Coil: The CAPEA4830D3 coil features a factory-installed electronic expansion valve (EEV) that precisely meters refrigerant flow across a wider range of operating conditions than fixed-orifice or standard TXV metering, supporting stable superheat and optimal heat transfer.
  • Dual Fuel Flexibility: This system automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature and the installer-configured balance point, allowing the homeowner to use the most cost-effective heating source as conditions change.
  • Cold Climate Heat Pump Operation: The GZV6SA4810A is rated for heating operation down to -10°F outdoor ambient, providing heat pump capacity even in extreme cold before the gas furnace takes over — reducing reliance on fossil fuel heating in moderate winter conditions.

Technical Specifications

Specification Value
AHRI Certificate Number 215487326
System Type Dual Fuel System
Nominal Capacity 4 Ton (48,000 BTU/h Nominal)
SEER2 17.0
HSPF2 8.2
Refrigerant R-32
Expansion Device EEV (Electronic Expansion Valve)
Furnace AFUE 80%
Furnace Input 80,000 BTU/h
Furnace Output 64,000 BTU/h
Outdoor Unit — GZV6SA4810A
Compressor Type Variable-Speed Swing
Max Cooling Capacity (95°F) 45,500 BTU/h
Max Heating Capacity (47°F) 45,500 BTU/h
Max Heating Capacity (5°F) 28,000 BTU/h
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 31.8A / 35A
Dimensions (WxDxH) 37" x 12-5/8" x 39"
Shipping Weight 185 lbs
Sound (Quiet Mode Lv.3) 57 dBA Sound Power / 45 dBA Sound Pressure
Indoor Coil — CAPEA4830D3
Configuration Upflow/Downflow (Cased)
Dimensions (WxDxH) 24-1/2" x 21" x 30"
Shipping Weight 70 lbs
Connections Liquid: 3/8" | Suction: 7/8" or 1-1/8"
Furnace — GRVT800805DN
Configuration Upflow/Horizontal
Gas Valve Two-Stage
Blower Motor Variable-Speed ECM
Dimensions (WxDxH) [NEEDS VERIFICATION] x 28" x 33-3/8"
Vent Diameter 4"
Shipping Weight 130 lbs
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Item Detail
Refrigerant R-32
Global Warming Potential (GWP) 675 (vs. R-410A at 2,088)
EPA Section 608 Requirements Type II or Universal Certification required for R-32 handling
AHRI Certified Yes — Certificate #215487326
ETL Listed Yes
ENERGY STAR Certified (System) Verify at energystar.gov for current matched-system status
Regional Compliance Verify local code requirements for NOx emissions standards
Tax Credit Eligibility No

Warranty & Registration

  • Outdoor Unit (GZV6SA4810A): 5-year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Daikin will furnish a new equivalent outdoor condensing unit as a one-time replacement (parts only; labor, refrigerant, and freight not included).
  • Indoor Evaporator Coil (CAPEA4830D3): 5-year Initial Term parts warranty. With online registration within 60 days: 10-year Registered Additional Term parts warranty. Parts only; labor not included.
  • Gas Furnace (GRVT800805DN): Heat Exchanger: 20-year Initial Term warranty (unregistered). With registration within 60 days: Lifetime heat exchanger coverage for the original registered owner. If the heat exchanger fails within the first 10 years in a registered unit, Daikin will furnish a new equivalent furnace as a one-time replacement. All other parts: 5-year Initial Term / 10-year Registered Additional Term warranty. Parts only; labor not included.
  • Important: All warranty terms require installation by a licensed contractor in an owner-occupied residence within the United States or Canada. Online registration must be completed within 60 days of installation at goodmanmfg.com. Some states and provinces do not require registration for extended coverage — check goodmanmfg.com/warranty-information for details. Warranty covers parts only; labor, refrigerant, and freight are the homeowner's responsibility.