Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman | 4 Ton | 16.2 SEER2 | R-32 | Dual Fuel System | GZV6SA4810A | CAPEA6030C3 | GDVM970804CN | 21" Cabinet Width | Upflow/Downflow | Cased Coil | 80,000 BTU | 97% AFUE | Downflow/Horizontal | Modulating | Variable-Speed ECM | Furnace

SKU: GZV6SA4810A-CAPEA6030C3-GDVM970804CN
Your Price:
$8,389.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

This Goodman Dual Fuel System pairs the GZV6SA4810A 4-ton variable-speed inverter-driven R-32 heat pump condenser with the CAPEA6030C3 upflow/downflow cased evaporator coil and the GDVM970804CN 97% AFUE modulating gas furnace. Rated at 16.2 SEER2 and 8.1 HSPF2 under AHRI Certificate #215488372, this matched system delivers variable-speed heat pump cooling and heating with gas furnace backup for sustained comfort in all climate conditions. The system uses R-32 refrigerant (GWP 675), a next-generation low-GWP alternative to R-410A that supports improved thermodynamic efficiency and reduced environmental impact.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • Outdoor Condensing Unit: Goodman GZV6SA4810A — 4-ton variable-speed inverter-driven R-32 heat pump with side-discharge cabinet, swing compressor, and EEV metering. Cold Climate rated with quiet-mode operation (as low as 45 dBA).
  • Indoor Evaporator Coil: Goodman CAPEA6030C3 — Upflow/Downflow cased all-aluminum evaporator coil with factory-installed EEV, 21" cabinet width, and R-32-optimized circuitry. 21" depth for easier attic/closet access.
  • Gas Furnace: Goodman GDVM970804CN — 80,000 BTU/h input / 77,600 BTU/h output, 97% AFUE, modulating gas valve, variable-speed ecm blower motor, downflow/horizontal configuration.

Pro-Installer Tip: When installing the GZV6SA4810A with the GDVM970804CN condensing furnace in a dual fuel configuration, route the condensate drain line from the secondary heat exchanger with a minimum 1/4" per foot slope to prevent condensate pooling that can corrode the collector box over time. In attic or horizontal installations, use a condensate pump or secondary drain pan with a float switch wired to the R-terminal to shut down the system if the primary drain fails — this prevents water damage that typically triggers a service call 6-12 months after installation. Verify the PVC flue vent termination meets NFPA 54/ANSI Z223.1 clearance requirements from operable windows and air intakes using a tape measure and level, and confirm combustion air supply sizing with a Manual D calculation or local code compliance check.

Key Benefits

  • Variable-Speed Inverter Efficiency: The GZV6SA4810A uses variable-speed swing compressor technology to ramp output up or down based on demand, achieving up to 16.2 SEER2 and 8.1 HSPF2 — reducing energy consumption compared to single-stage systems that cycle between full-on and full-off.
  • R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). R-32 also provides approximately 10% higher volumetric capacity than R-410A, enabling smaller compressor displacements for equivalent cooling output.
  • Quiet-Mode Operation: The outdoor unit features three selectable quiet-mode levels that reduce sound output to as low as 45 dBA sound pressure at 3 feet — approaching background noise levels for residential neighborhoods and suitable for installations near bedrooms or property lines.
  • EEV-Matched Indoor Coil: The CAPEA6030C3 coil features a factory-installed electronic expansion valve (EEV) that precisely meters refrigerant flow across a wider range of operating conditions than fixed-orifice or standard TXV metering, supporting stable superheat and optimal heat transfer.
  • Dual Fuel Flexibility: This system automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature and the installer-configured balance point, allowing the homeowner to use the most cost-effective heating source as conditions change.
  • Cold Climate Heat Pump Operation: The GZV6SA4810A is rated for heating operation down to -10°F outdoor ambient, providing heat pump capacity even in extreme cold before the gas furnace takes over — reducing reliance on fossil fuel heating in moderate winter conditions.

Technical Specifications

Specification Value
AHRI Certificate Number 215488372
System Type Dual Fuel System
Nominal Capacity 4 Ton (48,000 BTU/h Nominal)
SEER2 16.2
HSPF2 8.1
Refrigerant R-32
Expansion Device EEV (Electronic Expansion Valve)
Furnace AFUE 97%
Furnace Input 80,000 BTU/h
Furnace Output 77,600 BTU/h
Outdoor Unit — GZV6SA4810A
Compressor Type Variable-Speed Swing
Max Cooling Capacity (95°F) 45,500 BTU/h
Max Heating Capacity (47°F) 45,500 BTU/h
Max Heating Capacity (5°F) 28,000 BTU/h
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 31.8A / 35A
Dimensions (WxDxH) 37" x 12-5/8" x 39"
Shipping Weight 185 lbs
Sound (Quiet Mode Lv.3) 57 dBA Sound Power / 45 dBA Sound Pressure
Indoor Coil — CAPEA6030C3
Configuration Upflow/Downflow (Cased)
Dimensions (WxDxH) 21" x 21" x 30"
Shipping Weight 75 lbs
Connections Liquid: 3/8" | Suction: 7/8" or 1-1/8"
Furnace — GDVM970804CN
Configuration Downflow/Horizontal
Gas Valve Modulating
Blower Motor Variable-Speed ECM
Dimensions (WxDxH) [NEEDS VERIFICATION] x 28-7/8" x 34-1/2"
Vent Diameter 2" - 3" PVC
Shipping Weight 130 lbs
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Item Detail
Refrigerant R-32
Global Warming Potential (GWP) 675 (vs. R-410A at 2,088)
EPA Section 608 Requirements Type II or Universal Certification required for R-32 handling
AHRI Certified Yes — Certificate #215488372
ETL Listed Yes
ENERGY STAR Certified (System) Verify at energystar.gov for current matched-system status
Regional Compliance Verify local code requirements for NOx emissions standards
Tax Credit Eligibility Potentially eligible — consult tax professional for IRA/25C eligibility based on AFUE ≥ 97%

Warranty & Registration

  • Outdoor Unit (GZV6SA4810A): 5-year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Daikin will furnish a new equivalent outdoor condensing unit as a one-time replacement (parts only; labor, refrigerant, and freight not included).
  • Indoor Evaporator Coil (CAPEA6030C3): 5-year Initial Term parts warranty. With online registration within 60 days: 10-year Registered Additional Term parts warranty. Parts only; labor not included.
  • Gas Furnace (GDVM970804CN): Heat Exchanger: 20-year Initial Term warranty (unregistered). With registration within 60 days: Lifetime heat exchanger coverage for the original registered owner. If the heat exchanger fails within the first 10 years in a registered unit, Daikin will furnish a new equivalent furnace as a one-time replacement. All other parts: 5-year Initial Term / 10-year Registered Additional Term warranty. Parts only; labor not included.
  • Important: All warranty terms require installation by a licensed contractor in an owner-occupied residence within the United States or Canada. Online registration must be completed within 60 days of installation at goodmanmfg.com. Some states and provinces do not require registration for extended coverage — check goodmanmfg.com/warranty-information for details. Warranty covers parts only; labor, refrigerant, and freight are the homeowner's responsibility.