Goodman 5 Ton 15.5 SEER2 Dual Fuel System Overview
This AHRI-certified dual fuel system (Certificate #215447300) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT801005CX 100,000 BTU/h 80% AFUE gas furnace and the CAPEA6030C3 cased upflow/downflow evaporator coil. Rated at 15.5 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA6010 — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V/1Ph/60Hz electrical. Dimensions: 37" W x 12-5/8" D x 39" H. Equipment Weight: 168 lbs.
- CAPEA6030C3 — 5-Ton R-32 Cased Upflow/Downflow Cased Evaporator Coil with EEV expansion device. Upflow/Downflow configuration. Cabinet Dimensions: 21" W x 21" D x 30" H. Ship Weight: 75 lbs. Aluminum coil construction.
- GRVT801005CX — 100,000 BTU/h Input (80,000 BTU/h Output) 80% AFUE Two-Stage Low NOx Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21" W x 28" D x 33-3/8" H. Category I (Natural Draft / Induced Draft) venting (4").
Pro-Installer Tip
Technical Friction: Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CAPEA6030C3 evaporator coil above.
Long-Term Prevention: Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.
Expert Validation: Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02" to -0.10" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).
Professional Standard: This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.
Key Performance Benefits
- Dual Fuel Efficiency: Combines 15.5 SEER2 / 8.2 HSPF2 heat pump performance with 80% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.
- R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.
- Variable-Speed Compressor Technology: The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.
- Precise Airflow Management: The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot/cold spots and lowering operating noise compared to PSC motors.
- Two-Stage Gas Valve: Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.
- AHRI Certified Match: All components are AHRI-certified as a matched system (Certificate #215447300), ensuring rated performance is achieved when installed according to manufacturer specifications.
Technical Specifications
| System Performance Ratings (AHRI #215447300) | |
|---|---|
| SEER2 | 15.5 |
| EER2 | 8.5 |
| HSPF2 | 8.2 |
| Furnace AFUE | 80% |
| System Cooling Capacity | 53,500 BTU/h |
| System Heating Capacity (HP @ 47°F) | 54,500 BTU/h |
| Furnace Heating Input | 100,000 BTU/h |
| Refrigerant | R-32 |
| Coil-to-Furnace Fit | Flush-Fit |
| Outdoor Unit — GZV6SA6010 | |
| Dimensions (W x D x H) | 37" x 12-5/8" x 39" |
| Equipment / Ship Weight | 168 lbs / 198 lbs |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| MCA / MOP | 31.8A / 37.5A |
| Evaporator Coil — CAPEA6030C3 | |
| Configuration | Upflow/Downflow |
| Dimensions (W x D x H) | 21" x 21" x 30" |
| Ship Weight | 75 lbs |
| Gas Furnace — GRVT801005CX | |
| Configuration | Downflow |
| Dimensions (W x D x H) | 21" x 28" x 33-3/8" |
| Ship Weight | 124 lbs |
| Venting | Category I (Natural Draft / Induced Draft) — 4" diameter |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Refrigerant GWP | 675 (approximately 68% lower than R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 Certification | Required for all technicians handling R-32 refrigerant |
| Regional Compliance | Low NOx — Compliant with California 40 ng/J standard (not eligible for SCAQMD or SJVAPCD districts) |
| Federal Tax Credit Eligibility | No |
| AHRI Certification | Yes — Certificate #215447300 |
| Energy Star (Heat Pump) | No |
Warranty & Registration
Each component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.
- Outdoor Heat Pump (GZV6SA6010): 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.
- Evaporator Coil (CAPEA6030C3): 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.
- Gas Furnace (GRVT801005CX): Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.
Refer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...