Goodman 5 Ton 15.5 SEER2 Dual Fuel System Overview
This AHRI-certified dual fuel system (Certificate #215447275) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GMVS800805CU 80,000 BTU/h 80% AFUE gas furnace and the CHPEA6030D3 cased horizontal evaporator coil. Rated at 15.5 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. This configuration includes ComfortBridge communicating technology for enhanced system diagnostics and performance optimization. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA6010 — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V/1Ph/60Hz electrical. Dimensions: 37" W x 12-5/8" D x 39" H. Equipment Weight: 168 lbs.
- CHPEA6030D3 — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30" W x 21" D x 21" H. Ship Weight: 76 lbs. Aluminum coil construction.
- GMVS800805CU — 80,000 BTU/h Input (64,000 BTU/h Output) 80% AFUE Single-Stage Ultra Low NOx Gas Furnace. Variable-Speed ECM (ComfortBridge) circulator blower motor. Upflow/Horizontal configuration. Cabinet Dimensions: 21" W x 28" D x 33-3/8" H. Category I (Natural Draft / Induced Draft) venting (4").
Pro-Installer Tip
Technical Friction: This upflow/horizontal furnace paired with a cased horizontal coil creates a vertical stack that demands careful measurement of total installed height. The furnace stands 33-3/8" tall, and the CHPEA6030D3 adds 21" — verify ceiling clearance in utility closets before committing to this configuration, especially with the 1.75" offset coil-to-furnace alignment.
Long-Term Prevention: With the single-stage gas valve and variable-speed blower, ensure the thermostat or control board is properly configured for dual fuel switchover. Set the heat pump balance point based on regional heating design temperature — typically 35°F-40°F for moderate climates, 25°F-30°F for cold climates. An improperly set balance point results in excessive gas consumption that erases the efficiency gains of the 15.5 SEER2 heat pump.
Expert Validation: After completing the R-32 line set connections, evacuate to 500 microns or below using a digital micron gauge (not an analog compound gauge). Hold the vacuum for 10 minutes minimum with the core tool valve closed. R-32 is less forgiving of moisture contamination than R-410A due to its higher discharge temperatures.
Professional Standard: R-32 (GWP 675) falls under A2L classification per ASHRAE 34. Verify local code adoption of 2024 UMC or IMC provisions for A2L refrigerants. Installers must hold a valid EPA Section 608 certification and should verify charge limits per ASHRAE 15 based on room volume and ventilation rate of the equipment location.
Key Performance Benefits
- Dual Fuel Efficiency: Combines 15.5 SEER2 / 8.2 HSPF2 heat pump performance with 80% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.
- R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.
- Variable-Speed Compressor Technology: The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.
- Precise Airflow Management: The Variable-Speed ECM (ComfortBridge) blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot/cold spots and lowering operating noise compared to PSC motors.
- Single-Stage Gas Valve: Single-stage gas valve provides reliable heating output at full rated capacity.
- AHRI Certified Match: All components are AHRI-certified as a matched system (Certificate #215447275), ensuring rated performance is achieved when installed according to manufacturer specifications.
Technical Specifications
| System Performance Ratings (AHRI #215447275) | |
|---|---|
| SEER2 | 15.5 |
| EER2 | 8.4 |
| HSPF2 | 8.2 |
| Furnace AFUE | 80% |
| System Cooling Capacity | 53,500 BTU/h |
| System Heating Capacity (HP @ 47°F) | 53,500 BTU/h |
| Furnace Heating Input | 80,000 BTU/h |
| Refrigerant | R-32 |
| Coil-to-Furnace Fit | 1.75" Offset |
| Outdoor Unit — GZV6SA6010 | |
| Dimensions (W x D x H) | 37" x 12-5/8" x 39" |
| Equipment / Ship Weight | 168 lbs / 198 lbs |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| MCA / MOP | 31.8A / 37.5A |
| Evaporator Coil — CHPEA6030D3 | |
| Configuration | Horizontal |
| Dimensions (W x D x H) | 30" x 21" x 21" |
| Ship Weight | 76 lbs |
| Gas Furnace — GMVS800805CU | |
| Configuration | Upflow/Horizontal |
| Dimensions (W x D x H) | 21" x 28" x 33-3/8" |
| Ship Weight | 121 lbs |
| Venting | Category I (Natural Draft / Induced Draft) — 4" diameter |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Refrigerant GWP | 675 (approximately 68% lower than R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 Certification | Required for all technicians handling R-32 refrigerant |
| Regional Compliance | Ultra Low NOx — Eligible for California SCAQMD Rule 1111 and SJVAPCD Rule 4905 districts |
| Federal Tax Credit Eligibility | No |
| AHRI Certification | Yes — Certificate #215447275 |
| Energy Star (Heat Pump) | No |
Warranty & Registration
Each component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.
- Outdoor Heat Pump (GZV6SA6010): 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.
- Evaporator Coil (CHPEA6030D3): 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.
- Gas Furnace (GMVS800805CU): Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.
Refer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...