Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVS960805CU | CAPEA6030C3 | 21" Cabinet Width | Upflow/Downflow | Coil | 80,000 BTU | Upflow/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace

SKU: GZV6SA6010-GRVS960805CU-CAPEA6030C3
Your Price:
$9,211.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

Goodman 5 Ton 15.2 SEER2 Dual Fuel System Overview

This AHRI-certified dual fuel system (Certificate #215447304) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVS960805CU 96% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU/h in cooling and 54,500 BTU/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA6010 — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37" W x 12⅝" D x 39" H)
  • GRVS960805CU — Goodman 80,000 BTU/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow/Horizontal, 21" Cabinet, Ultra-Low NOx)
  • CAPEA6030C3 — Goodman Upflow/Downflow Cased Evaporator Coil with EEV (21" W x 21" D x 30" H)

Pro-Installer Tip

Technical Friction: Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.

Long-Term Prevention: During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.

Expert Validation: Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.

Professional Standard: R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.

Key Performance Benefits

  • High-Efficiency Cooling & Heating: Up to 15.2 SEER2 / 8.3 EER2 / 8.2 HSPF2 ratings verified through AHRI certification (#215447304), delivering dependable seasonal performance across varying climate conditions.
  • Next-Generation R-32 Refrigerant: R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.
  • Variable-Speed Compressor Technology: The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.
  • Quiet Operation: Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.
  • Dual Fuel Versatility: Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.

Technical Specifications

Specification Value
AHRI Certificate Number 215447304
System Type Dual Fuel System
Nominal Capacity 5 Ton (60,000 BTU/h Nominal)
SEER2 Rating 15.2
EER2 Rating 8.3
HSPF2 Rating 8.2
Max Cooling Capacity 53,500 BTU/h at 95°F
Max Heating Capacity (47°F) 54,500 BTU/h
Max Heating Capacity (5°F) 33,000 BTU/h
Refrigerant Type R-32
Factory Charge 118 oz
Expansion Device EEV (Electronic Expansion Valve)
Compressor Type Variable-Speed Swing
Outdoor Unit — GZV6SA6010
Dimensions (W x D x H) 37" x 12⅝" x 39"
Equipment Weight 179 lbs
Electrical 208-230V / 1 Phase / 60 Hz
Min. Circuit Ampacity (MCA) 37.5A
Max Overcurrent Protection 40A
Liquid Line ⅜"
Suction Line 1⅛"
Gas Furnace — GRVS960805CU
AFUE 96%
Input BTU/h 80,000
Gas Valve Type Single-Stage
Motor Variable-Speed ECM
Configuration Upflow/Horizontal
Cabinet Width 21"
Dimensions (W x D x H) 21" x 28⅞" x 34½"
Venting 2" - 3" PVC
Electrical 120V / 1 Phase / 60 Hz
Evaporator Coil — CAPEA6030C3
Configuration Upflow/Downflow, Cased
Dimensions (W x D x H) 21" x 21" x 30"
Expansion Device EEV (Electronic Expansion Valve)
Weight 75 lbs
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Detail
Refrigerant Type R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (approximately 68% lower than R-410A at 2,088)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Requirements Certified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act
Regional Compliance All Regions — meets DOE 2023 minimum efficiency standards
AHRI Certified Yes (Certificate #{ahri})
ETL Listed Yes
Energy Star Cold Climate No
Federal Tax Credit Eligibility (25C) Verify eligibility with a qualified tax professional based on installed SEER2/HSPF2 ratings and current IRS requirements.
NOx Emissions Ultra-Low NOx (≤14 ng/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements

Warranty & Registration

  • Outdoor Unit (GZV6SA6010): 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.
  • Gas Furnace (GRVS960805CU): 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.
  • Evaporator Coil (CAPEA6030C3): 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.