Goodman 2-Ton 16.0 SEER2 R-32 Heat Pump Condenser and Evaporator Coil System
This AHRI-certified heat pump condenser and evaporator coil system that pairs the Goodman GZV7SA2410 2-ton R-32 variable-speed inverter-driven heat pump condenser with the CHPEA3026B3 horizontal evaporator coil with internal EEV. Rated at up to 16.0 SEER2 / 8.5 HSPF2 with 23,200 BTU/h cooling and 23,200 BTU/h heating capacity (47°F), this system uses R-32 refrigerant (GWP 675) — a lower-GWP alternative to R-410A. The outdoor unit features a variable-speed swing compressor, EEV metering, and quiet-mode operation as low as 45 dBA. AHRI Certificate Number: 217577965. ENERGY STAR® Cold Climate certified and recognized as ENERGY STAR Most Efficient.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV7SA2410 — Goodman 2-Ton R-32 Variable-Speed Inverter-Driven Side-Discharge Heat Pump Condenser (208-230V/1Ph/60Hz) | Dimensions: 36⅝"W x 13¾"D x 27⅜"H | Equipment Weight: 132 lbs
- CHPEA3026B3 — Goodman Horizontal Cased Indoor Evaporator Coil with Internal EEV | Dimensions: 26"W x 21"D x 17½"H | Ship Weight: 63 lbs
🛠 Pro-Installer Tip: Coil-Only System & Metering Device Verification
Technical Friction: The CHPEA3026B3 coil paired directly with the GZV7SA2410 condenser without a communicating furnace or blower means the existing air mover must provide adequate and consistent airflow. In retrofit scenarios where this coil replaces an older R-410A unit, verify the existing blower can deliver 350–400 CFM per ton (700–800 CFM for this 2-ton system) against the static pressure of the new coil.
Long-Term Prevention: After initial startup, verify the EEV is modulating correctly by observing superheat stability over a 10-minute period. An EEV that hunts (oscillates more than ±3°F) may indicate an oversized or undersized line set, incorrect charge, or a communication fault between the coil’s EEV controller and the outdoor unit. Catching this during commissioning prevents efficiency degradation and compressor wear over the first heating season.
Expert Validation: Use a digital manifold with R-32 profiles to verify subcooling at 14±1°F at the outdoor service valve. Cross-check with the EEV step count displayed on the coil’s diagnostic board — it should be within the manufacturer’s specified range for the current operating conditions.
Professional Standard: All R-32 (A2L) installations must comply with EPA Section 608, UL 60335-2-40, and local mechanical code. Verify the installer holds current EPA 608 Universal certification and that the jurisdiction permits A2L refrigerant systems in the intended application space.
Key System Benefits
- ✅ High Efficiency: Rated at up to 16.0 SEER2 / 8.5 HSPF2, this system meets or exceeds DOE 2023 minimum efficiency standards and qualifies for ENERGY STAR Cold Climate certification, demonstrating reliable heating performance down to 5°F ambient (15,800 BTU/h at 5°F).
- ✅ Lower-GWP Refrigerant: R-32 has a Global Warming Potential (GWP) of 675, approximately 68% lower than R-410A (GWP 2,088). This supports federal HFC phasedown mandates under the AIM Act and may qualify for additional regional utility rebates.
- ✅ Variable-Speed Comfort: The inverter-driven swing compressor modulates capacity from approximately 30% to 100%, reducing temperature swings and improving humidity control compared to single-stage or two-stage systems. The digitally commutated fan motor provides quiet, efficient outdoor airflow.
- ✅ Quiet Operation: Normal-mode cooling sound power of 67 dBA with a three-level quiet mode that can reduce outdoor noise to as low as 45 dBA — suitable for installations near bedrooms, patios, or properties with local noise ordinances.
Technical Specifications
| Specification | Value |
|---|---|
| AHRI Certificate Number | 217577965 |
| System Type | Heat Pump Condenser and Evaporator Coil System |
| Nominal Capacity | 2 Tons |
| SEER2 | 16.0 |
| HSPF2 | 8.5 |
| EER2 | 10.5 |
| Cooling Capacity (95°F) | 23,200 BTU/h |
| Heating Capacity (47°F) | 23,200 BTU/h |
| Heating Capacity (5°F) | 15,800 BTU/h |
| Refrigerant | R-32 |
| Refrigerant Charge | 76 oz (for 15 ft line set) |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Compressor Type | Variable-Speed Swing |
| Outdoor Unit Voltage | 208-230V / 1 Phase / 60 Hz |
| Outdoor Unit MCA | 22.4 Amps |
| Outdoor Unit MOCP | 25 Amps |
| Outdoor Unit Dimensions (WxDxH) | 36⅝" x 13¾" x 27⅜" |
| Outdoor Unit Weight | 132 lbs (Equipment) / 147 lbs (Shipping) |
| Sound Level (Cooling, Normal Mode) | 67 dBA (Sound Power) |
| Sound Level (Quiet Mode, Lowest) | 45 dBA |
| Evaporator Coil Model | CHPEA3026B3 |
| Coil Configuration | Horizontal |
| Coil Dimensions (WxDxH) | 26" x 21" x 17½" |
| Coil Ship Weight | 63 lbs |
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane, A2L Classification) |
| Global Warming Potential (GWP) | 675 (approximately 68% lower than R-410A) |
| EPA Section 608 | Universal certification required for all technicians handling R-32. A2L refrigerant handling procedures apply per UL 60335-2-40. |
| AHRI Certification | Yes — Certificate #217577965 |
| ENERGY STAR® | Cold Climate Certified; ENERGY STAR Most Efficient 2025 |
| Regional Compliance | Meets DOE 2023 minimum efficiency standards for all U.S. climate regions. Verify local jurisdiction has adopted A2L refrigerant provisions (2024 UMC or equivalent). |
| Federal Tax Credit Eligibility | Systems meeting CEE highest efficiency tier requirements may qualify for federal tax credits under the Inflation Reduction Act (IRA) §25C. Consult a qualified tax professional for eligibility based on installed system SEER2/HSPF2 ratings. |
| Florida Building Code | When properly anchored, outdoor unit meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds. |
Warranty & Registration
Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage described below.
- GZV7SA2410 Heat Pump Condenser: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty plus 10-year unit replacement limited warranty for compressor failure (one-time replacement of entire outdoor unit). Quiet-mode, variable-speed swing compressor, and all factory-installed components are covered under parts warranty. Registration at www.goodmanmfg.com.
- CHPEA3026B3 Evaporator Coil: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty covering the all-aluminum coil, internal EEV, R-32 sensor, and all factory-installed components. Registration at www.goodmanmfg.com.
Warranty terms apply to units installed in owner-occupied residences within the United States, its territories, or Canada. Different warranty terms apply to non-owner-occupied residences and commercial installations. Some states and provinces do not allow warranty coverage to be conditioned on registration. Refer to the complete warranty document for full terms, conditions, limitations, and exclusions.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...