Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 2 Ton 19.0 SEER2 R-32 Dual Fuel System | GZV7SA2410 | GRVS960603BU | CHPEA3026B3 | 26" Cabinet Width Horizontal Coil | 60,000 BTU/h Upflow/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace

SKU: GZV7SA2410-CHPEA3026B3-GRVS960603BU-215434122
Your Price:
$0.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

Goodman 2-Ton 19.0 SEER2 R-32 Dual Fuel System

This AHRI-certified dual fuel system that pairs the Goodman GZV7SA2410 2-ton R-32 variable-speed inverter-driven heat pump condenser with the GRVS960603BU 96% AFUE single-stage gas furnace (60,000 BTU/h) and the CHPEA3026B3 horizontal evaporator coil with internal EEV. Rated at up to 19.0 SEER2 / 8.6 HSPF2 with 23,200 BTU/h cooling and 23,200 BTU/h heating capacity (47°F), this system uses R-32 refrigerant (GWP 675) — a lower-GWP alternative to R-410A. The outdoor unit features a variable-speed swing compressor, EEV metering, and quiet-mode operation as low as 45 dBA. AHRI Certificate Number: 215434122. ENERGY STAR® Cold Climate certified and recognized as ENERGY STAR Most Efficient.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV7SA2410 — Goodman 2-Ton R-32 Variable-Speed Inverter-Driven Side-Discharge Heat Pump Condenser (208-230V/1Ph/60Hz) | Dimensions: 36⅝"W x 13¾"D x 27⅜"H | Equipment Weight: 132 lbs
  • CHPEA3026B3 — Goodman Horizontal Cased Indoor Evaporator Coil with Internal EEV | Dimensions: 26"W x 21"D x 17½"H | Ship Weight: 63 lbs
  • GRVS960603BU — Goodman 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace | 60,000 BTU/h | Upflow/Horizontal | Cabinet Width: 17½" | Ultra Low NOx

🛠 Pro-Installer Tip: Dual Fuel Changeover & R-32 Line Set Considerations

Technical Friction: The GZV7SA2410 uses R-32 refrigerant at operating pressures approximately 15% higher than R-410A. When pairing with the GRVS960603BU furnace in a upflow/horizontal configuration, verify the balance point temperature is set correctly on the communicating thermostat — an incorrect changeover setpoint between heat pump and gas heat results in either excessive strip-heat usage or short-cycling the compressor in marginal ambient temperatures.

Long-Term Prevention: After commissioning, verify subcooling at the service valve reads 14±1°F per the manufacturer’s charging chart. Document this baseline on the unit’s service tag. Six to twelve months later, a deviation of more than 2°F from this baseline is an early indicator of refrigerant migration or a developing EEV restriction — catching it then prevents a no-heat emergency call in peak winter.

Expert Validation: Use a digital manifold gauge set rated for R-32 pressures (minimum 800 PSI high-side). Confirm superheat and subcooling with a calibrated clamp thermometer. The Testo 557s or Fieldpiece SMAN480 both support R-32 refrigerant profiles natively.

Professional Standard: R-32 is classified A2L (mildly flammable). Per EPA Section 608 and UL 60335-2-40, all service personnel must hold valid EPA 608 certification, and installation must comply with local mechanical code amendments for A2L refrigerants. Verify the jurisdiction has adopted 2024 UMC or equivalent provisions for reduced-GWP refrigerant charge limits in occupied spaces.

Key System Benefits

  • High Efficiency: Rated at up to 19.0 SEER2 / 8.6 HSPF2, this system meets or exceeds DOE 2023 minimum efficiency standards and qualifies for ENERGY STAR Cold Climate certification, demonstrating reliable heating performance down to 5°F ambient (15,800 BTU/h at 5°F).
  • Lower-GWP Refrigerant: R-32 has a Global Warming Potential (GWP) of 675, approximately 68% lower than R-410A (GWP 2,088). This supports federal HFC phasedown mandates under the AIM Act and may qualify for additional regional utility rebates.
  • Variable-Speed Comfort: The inverter-driven swing compressor modulates capacity from approximately 30% to 100%, reducing temperature swings and improving humidity control compared to single-stage or two-stage systems. The digitally commutated fan motor provides quiet, efficient outdoor airflow.
  • Quiet Operation: Normal-mode cooling sound power of 67 dBA with a three-level quiet mode that can reduce outdoor noise to as low as 45 dBA — suitable for installations near bedrooms, patios, or properties with local noise ordinances.
  • Dual Fuel Flexibility: Combines electric heat pump heating with 60,000 BTU/h gas furnace backup at 96% AFUE, allowing the system to automatically switch to the most cost-effective heating source based on outdoor temperature. This is particularly advantageous in regions with variable fuel and electricity pricing.

Technical Specifications

Specification Value
AHRI Certificate Number 215434122
System Type Dual Fuel System
Nominal Capacity 2 Tons
SEER2 19.0
HSPF2 8.6
EER2 11.0
Cooling Capacity (95°F) 23,200 BTU/h
Heating Capacity (47°F) 23,200 BTU/h
Heating Capacity (5°F) 15,800 BTU/h
Refrigerant R-32
Refrigerant Charge 76 oz (for 15 ft line set)
Expansion Device EEV (Electronic Expansion Valve)
Compressor Type Variable-Speed Swing
Outdoor Unit Voltage 208-230V / 1 Phase / 60 Hz
Outdoor Unit MCA 22.4 Amps
Outdoor Unit MOCP 25 Amps
Outdoor Unit Dimensions (WxDxH) 36⅝" x 13¾" x 27⅜"
Outdoor Unit Weight 132 lbs (Equipment) / 147 lbs (Shipping)
Sound Level (Cooling, Normal Mode) 67 dBA (Sound Power)
Sound Level (Quiet Mode, Lowest) 45 dBA
Evaporator Coil Model CHPEA3026B3
Coil Configuration Horizontal
Coil Dimensions (WxDxH) 26" x 21" x 17½"
Coil Ship Weight 63 lbs
Furnace Model GRVS960603BU
AFUE 96%
Furnace Input 60,000 BTU/h
Gas Valve Single-Stage
Furnace Configuration Upflow/Horizontal
Furnace Cabinet Width 17½"
Furnace Motor Variable-Speed ECM
NOx Rating Ultra Low NOx

Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane, A2L Classification)
Global Warming Potential (GWP) 675 (approximately 68% lower than R-410A)
EPA Section 608 Universal certification required for all technicians handling R-32. A2L refrigerant handling procedures apply per UL 60335-2-40.
AHRI Certification Yes — Certificate #215434122
ENERGY STAR® Cold Climate Certified; ENERGY STAR Most Efficient 2025
Regional Compliance Meets DOE 2023 minimum efficiency standards for all U.S. climate regions. Verify local jurisdiction has adopted A2L refrigerant provisions (2024 UMC or equivalent).
Federal Tax Credit Eligibility Systems meeting CEE highest efficiency tier requirements may qualify for federal tax credits under the Inflation Reduction Act (IRA) §25C. Consult a qualified tax professional for eligibility based on installed system SEER2/HSPF2 ratings.
Florida Building Code When properly anchored, outdoor unit meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds.

Warranty & Registration

Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage described below.

  • GZV7SA2410 Heat Pump Condenser: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty plus 10-year unit replacement limited warranty for compressor failure (one-time replacement of entire outdoor unit). Quiet-mode, variable-speed swing compressor, and all factory-installed components are covered under parts warranty. Registration at www.goodmanmfg.com.
  • CHPEA3026B3 Evaporator Coil: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty covering the all-aluminum coil, internal EEV, R-32 sensor, and all factory-installed components. Registration at www.goodmanmfg.com.
  • GRVS960603BU Gas Furnace: Unregistered (Initial Term): 20-year heat exchanger limited warranty and 5-year all other parts limited warranty. Registered (within 60 days): Lifetime heat exchanger limited warranty (for as long as the original registered owner resides in the home, up to 10 years for unit replacement if heat exchanger fails) and 10-year all other parts limited warranty. Registration at www.goodmanmfg.com.

Warranty terms apply to units installed in owner-occupied residences within the United States, its territories, or Canada. Different warranty terms apply to non-owner-occupied residences and commercial installations. Some states and provinces do not allow warranty coverage to be conditioned on registration. Refer to the complete warranty document for full terms, conditions, limitations, and exclusions.