Goodman 2 Ton 19.0 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil & Modular Blower | GZV7SA2410 | CHPEA3026C3 | MBVK12BP1X00 | 26" Cabinet Width Horizontal Coil | 17½" Multi-Positional Modular Blower

SKU: GZV7SA2410-CHPEA3026C3-MBVK12BP1X00-215433909
Your Price:
$4,883.00 $6,592.00
You Save: $1,709.00 26%
Checkout Secure

Quantity Remaining:

302 of 400 Sold
Order in the next to get it by

Goodman 2-Ton 19.0 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil & Modular Blower

This AHRI-certified central heat pump split system that pairs the Goodman GZV7SA2410 2-ton R-32 variable-speed inverter-driven heat pump condenser with the CHPEA3026C3 horizontal evaporator coil (internal EEV) and the MBVK12BP1X00 multi-positional variable-speed modular blower. Rated at up to 19.0 SEER2 / 8.6 HSPF2 with 23,200 BTU/h cooling and 23,200 BTU/h heating capacity (47°F), this system uses R-32 refrigerant (GWP 675) — a lower-GWP alternative to R-410A. The outdoor unit features a variable-speed swing compressor, EEV metering, and quiet-mode operation as low as 45 dBA. AHRI Certificate Number: 215433909. ENERGY STAR® Cold Climate certified and recognized as ENERGY STAR Most Efficient.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV7SA2410 — Goodman 2-Ton R-32 Variable-Speed Inverter-Driven Side-Discharge Heat Pump Condenser (208-230V/1Ph/60Hz) | Dimensions: 36⅝"W x 13¾"D x 27⅜"H | Equipment Weight: 132 lbs
  • CHPEA3026C3 — Goodman Horizontal Cased Indoor Evaporator Coil with Internal EEV | Dimensions: 26"W x 21"D x 21"H | Ship Weight: 67 lbs
  • MBVK12BP1X00 — Goodman Multi-Positional Variable-Speed ECM Modular Blower | 17½"W x 21"D x 26"H | ½ HP Motor | Ship Weight: 67 lbs

🛠 Pro-Installer Tip: Two-Piece System Alignment & Communicating Setup

Technical Friction: The CHPEA3026C3 coil mated to the MBVK12BP1X00 modular blower creates a two-piece indoor section. Physical alignment between the coil drain pan and blower cabinet transition is critical — even a ¼" offset at the seam can cause condensate to pool at the joint rather than draining properly, especially in horizontal installations where gravity assistance is minimal.

Long-Term Prevention: After assembly, run the system in high-speed cooling for 20 minutes and inspect the coil-to-blower seam for any condensate weeping. Apply foil-faced mastic tape at the joint and verify the secondary drain pan (if required by code for attic installations) is properly sloped. This prevents water damage callbacks that typically appear 2–3 months into the first cooling season.

Expert Validation: Use a digital torpedo level to confirm ¼" per foot slope toward the primary drain connection. Verify the communicating link between the modular blower and the GZV7SA2410 outdoor unit is established via the two-wire ComfortBridge connection — the blower’s diagnostic LED should show a steady heartbeat pattern confirming communication.

Professional Standard: Per the 2024 UMC and local amendments for A2L refrigerants, the R-32 sensor integrated into the CHPEA3026C3 coil must be verified operational before completing commissioning. Confirm EPA 608 certification is current for all technicians handling R-32 refrigerant.

Key System Benefits

  • High Efficiency: Rated at up to 19.0 SEER2 / 8.6 HSPF2, this system meets or exceeds DOE 2023 minimum efficiency standards and qualifies for ENERGY STAR Cold Climate certification, demonstrating reliable heating performance down to 5°F ambient (15,800 BTU/h at 5°F).
  • Lower-GWP Refrigerant: R-32 has a Global Warming Potential (GWP) of 675, approximately 68% lower than R-410A (GWP 2,088). This supports federal HFC phasedown mandates under the AIM Act and may qualify for additional regional utility rebates.
  • Variable-Speed Comfort: The inverter-driven swing compressor modulates capacity from approximately 30% to 100%, reducing temperature swings and improving humidity control compared to single-stage or two-stage systems. The digitally commutated fan motor provides quiet, efficient outdoor airflow.
  • Quiet Operation: Normal-mode cooling sound power of 67 dBA with a three-level quiet mode that can reduce outdoor noise to as low as 45 dBA — suitable for installations near bedrooms, patios, or properties with local noise ordinances.

Technical Specifications

Specification Value
AHRI Certificate Number 215433909
System Type Central Heat Pump Split System with Evaporator Coil & Modular Blower
Nominal Capacity 2 Tons
SEER2 19.0
HSPF2 8.6
EER2 11.0
Cooling Capacity (95°F) 23,200 BTU/h
Heating Capacity (47°F) 23,200 BTU/h
Heating Capacity (5°F) 15,800 BTU/h
Refrigerant R-32
Refrigerant Charge 76 oz (for 15 ft line set)
Expansion Device EEV (Electronic Expansion Valve)
Compressor Type Variable-Speed Swing
Outdoor Unit Voltage 208-230V / 1 Phase / 60 Hz
Outdoor Unit MCA 22.4 Amps
Outdoor Unit MOCP 25 Amps
Outdoor Unit Dimensions (WxDxH) 36⅝" x 13¾" x 27⅜"
Outdoor Unit Weight 132 lbs (Equipment) / 147 lbs (Shipping)
Sound Level (Cooling, Normal Mode) 67 dBA (Sound Power)
Sound Level (Quiet Mode, Lowest) 45 dBA
Evaporator Coil Model CHPEA3026C3
Coil Configuration Horizontal
Coil Dimensions (WxDxH) 26" x 21" x 21"
Coil Ship Weight 67 lbs
Modular Blower Model MBVK12BP1X00
Blower Configuration Multi-Positional
Blower Dimensions (WxDxH) 17½" x 21" x 26"
Blower Motor ½ HP Variable-Speed ECM
Blower Ship Weight 67 lbs

Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane, A2L Classification)
Global Warming Potential (GWP) 675 (approximately 68% lower than R-410A)
EPA Section 608 Universal certification required for all technicians handling R-32. A2L refrigerant handling procedures apply per UL 60335-2-40.
AHRI Certification Yes — Certificate #215433909
ENERGY STAR® Cold Climate Certified; ENERGY STAR Most Efficient 2025
Regional Compliance Meets DOE 2023 minimum efficiency standards for all U.S. climate regions. Verify local jurisdiction has adopted A2L refrigerant provisions (2024 UMC or equivalent).
Federal Tax Credit Eligibility Systems meeting CEE highest efficiency tier requirements may qualify for federal tax credits under the Inflation Reduction Act (IRA) §25C. Consult a qualified tax professional for eligibility based on installed system SEER2/HSPF2 ratings.
Florida Building Code When properly anchored, outdoor unit meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds.

Warranty & Registration

Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage described below.

  • GZV7SA2410 Heat Pump Condenser: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty plus 10-year unit replacement limited warranty for compressor failure (one-time replacement of entire outdoor unit). Quiet-mode, variable-speed swing compressor, and all factory-installed components are covered under parts warranty. Registration at www.goodmanmfg.com.
  • CHPEA3026C3 Evaporator Coil: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty covering the all-aluminum coil, internal EEV, R-32 sensor, and all factory-installed components. Registration at www.goodmanmfg.com.
  • MBVK12BP1X00 Modular Blower: Unregistered (Initial Term): 5-year parts limited warranty. Registered (within 60 days): 10-year parts limited warranty covering the variable-speed ECM blower motor and all factory-installed components. Registration at www.goodmanmfg.com.

Warranty terms apply to units installed in owner-occupied residences within the United States, its territories, or Canada. Different warranty terms apply to non-owner-occupied residences and commercial installations. Some states and provinces do not allow warranty coverage to be conditioned on registration. Refer to the complete warranty document for full terms, conditions, limitations, and exclusions.