Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 5 Ton 15.5 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030D3 | GMVS960805CU | Communicating | 21" Cabinet Depth Horizontal Coil | 80,000 BTU/h 96.0% AFUE Upflow/Horizontal Ultra Low NOx Single-Stage Furnace

SKU: GZV7SA6010-CHPEA6030D3-GMVS960805CU
Your Price:
$0.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

System Overview

This Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030D3 cased evaporator coil and the GMVS960805CU 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #217495908) and rated at 15.5 SEER2 / 9.8 EER2 / 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.

Dual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

What’s Included

  • GZV7SA6010 — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU/h Cooling / 54,000 BTU/h Heating @ 47°F)
  • CHPEA6030D3 — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 21" Cabinet Depth, Internal EEV, All-Aluminum
  • GMVS960805CU — Goodman 80,000 BTU/h Input 96.0% AFUE Single-Stage Upflow/Horizontal Gas Furnace, Variable-Speed ECM, Ultra Low NOx

Pro-Installer Tip: Dual Fuel Changeover and Line Set Considerations

The Technical Friction: On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞" suction valve ports but requires 1⅛" suction line sets. Installers will need to supply ⅞" to 1⅛" adapters for suction line connections. Confirm the furnace’s upflow/horizontal configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.

The Long-Term Prevention: Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.

The Expert Validation: After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.

The Professional Standard: R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.

Key System Benefits

  • Variable-Speed Inverter Technology: The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.
  • ENERGY STAR Cold Climate Certified: This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU/h at 5°F and supporting operation down to -10°F.
  • R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.
  • Electronic Expansion Valve (EEV) Metering: Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.
  • Dual Fuel Economy: Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.
  • Communicating System Architecture: When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.

Technical Specifications

Specification Value
AHRI Certificate Number 217495908
System Type Dual Fuel System
Nominal Capacity 5 Ton (60,000 BTU/h)
SEER2 15.5
EER2 9.8
HSPF2 8.5
Furnace AFUE 96.0%
Refrigerant R-32 (Charge: 162 oz.)
Outdoor Unit — GZV7SA6010
Max Cooling Capacity 52,000 BTU/h @ 95°F
Max Heating Capacity 54,000 BTU/h @ 47°F
Max Heating Capacity (Low Temp) 46,000 BTU/h @ 5°F
Compressor Type Variable-Speed Swing
Dimensions (W x D x H) 37"W x 12⅝"D x 56⁵⁄₁₆"H
Unit Weight 236 lbs
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 34.4A / 40A
Ambient Operating Range (Cooling) 0°F to 115°F
Ambient Operating Range (Heating) -10°F to 70°F
Evaporator Coil — CHPEA6030D3
Configuration Horizontal (Cased)
Dimensions (W x D x H) 30" x 21" x 21"
Expansion Device EEV (Electronic Expansion Valve)
Coil Material All-Aluminum
Ship Weight 76 lbs
Gas Furnace — GMVS960805CU
Heating Input 80,000 BTU/h
AFUE 96.0%
Stages Single-Stage
Configuration Upflow/Horizontal
Motor Variable-Speed ECM
Gas Type Ultra Low NOx

Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental

Requirement Details
Refrigerant Type R-32 (Difluoromethane)
GWP (Global Warming Potential) 675
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Certification Required for all technicians handling R-32
AIM Act Compliance R-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC/HP)
ENERGY STAR® ENERGY STAR Cold Climate Certified
Regional Compliance All Regions (A-Rating)
Federal Tax Credit Eligibility Systems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.

Warranty & Registration

  • Outdoor Unit (GZV7SA6010): 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.
  • Evaporator Coil (CHPEA6030D3): 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.
  • Gas Furnace (GMVS960805CU): Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.

Warranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.