Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman GPHH52431 R-32 Packaged Heat Pump – 2 Ton, 15.0 SEER2 (Single-stage)

SKU: GPHH52431
Your Price:
$5,013.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

GPHH52431 is a 2 Ton Goodman GPHH5 R-32 packaged heat pump designed for ducted heating and cooling where an all-in-one outdoor cabinet makes sense (common in rooftop or slab applications). This model provides rated cooling up to 23,600 BTU/h and rated heating of 24,000 BTU/h @ 47°F, with an efficiency rating of 15.0 SEER2.

At-a-glance specifications

Model number GPHH52431
Series GPHH5 (Packaged Heat Pump)
Nominal size 2 Ton
Cooling capacity (rated) 23,600 BTU/h total • 18,408 BTU/h sensible
Efficiency ratings 15.0 SEER2 • 11.2 EER2 • 7.0 HSPF2
Heating capacity (rated) 24,000 BTU/h @ 47°F (COP 3.8) • 13,000 BTU/h @ 17°F (COP 2.4)
Compressor Scroll, Single-stage (RLA 10.62, LRA 56.5)
Indoor blower 875 nominal CFM • ECM multi-speed (5 speeds) • 1/2 HP • 3.8 FLA • wheel 10 x 8"
Outdoor fan 22" blade • 1/6 HP • 0.95 FLA
Sound rating 76 dB
Electrical 208-230 V, 1-phase, 60 Hz • MCA 18.03 A • Max overcurrent protection 25 A
Refrigerant charge 98 oz (6.12 lb / 2.78 kg)
Cabinet / footprint 66" W × 34" D × 30" H (overall B height); cabinet height A = 27.5" • Chassis size: Small • Duct openings: Supply 14" × 14" • Return 14" × 22"
Minimum clearances Per the spec-sheet diagram: maintain 36" clearance on the air-inlet/service sides and 10" to an adjacent wall on the opposite side; follow local code and installation instructions.
Factory charge Shipped fully charged with R-32 (ready for start-up after installation and checkout)
Optional heat Electric heat kits are available as field-installed options (sold separately; sizing and electrical requirements depend on kit)

Model number decoding (so you know exactly what you're buying)

  • G = Goodman brand
  • P = Packaged unit (all-in-one outdoor cabinet)
  • H = Heat pump
  • H = Horizontal discharge configuration
  • 5 = 15.2 SEER2 series
  • 24 = 2 Ton
  • 31 = 208/230V, 1-Phase, 60Hz
  • Refrigerant = R-32 (A2L)

Performance details

  • Cooling: 23,600 BTU/h total, 18,408 BTU/h sensible; 15.0 SEER2; 11.2 EER2.
  • Heating: 24,000 BTU/h @ 47°F (COP 3.8); 13,000 BTU/h @ 17°F (COP 2.4); 7.0 HSPF2.
  • Staging: Single-stage. (Two-stage models can run at a lower stage in mild conditions for steadier comfort.)

Air delivery & comfort

  • Indoor blower: Multi-speed ECM with 5 speeds; 875 nominal CFM; blower wheel 10 x 8"; motor 1/2 HP.
  • Duct connections: Supply 14" × 14" • Return 14" × 22" (check transitions/curb requirements).

Refrigerant, coils, and serviceability

  • Refrigerant: R-32, factory charge 98 oz (6.12 lb / 2.78 kg).
  • Coils: All-aluminum evaporator coil; copper tube/aluminum fin condenser coil.
  • Drain connection: 3/4" NPT.

Metering devices: Indoor/evaporator metering is TXV. Outdoor/condenser metering is Piston. A TXV (thermostatic expansion valve) is a modulating metering device; a piston (fixed orifice) is a fixed metering device—your installer/service technician will want to know this for diagnostics and part selection.

Electrical requirements (verify the nameplate before installation)

  • Power: 208-230 V, 1-phase, 60 Hz.
  • MCA / breaker sizing: Minimum circuit ampacity 18.03 A; max overcurrent protection 25 A (time-delay fuses or HACR-type breakers per spec sheet).

Physical dimensions, clearances & sound

  • Cabinet size: 66" W × 34" D × 30" H (overall B height); cabinet height A = 27.5" (chassis: Small).
  • Operating/shipping weight: 350 lb operating / 360 lb shipping.
  • Sound rating: 76 dB.
  • Clearances: Per the spec-sheet diagram: maintain 36" clearance on the air-inlet/service sides and 10" to an adjacent wall on the opposite side; follow local code and installation instructions.

Standard features

  • High-efficiency scroll compressor
  • Multi-speed ECM indoor blower motor (5 speeds)
  • Copper tube/aluminum fin condenser coil
  • All-aluminum evaporator coil
  • Totally enclosed, permanently lubricated condenser fan motor
  • Fully charged system
  • Quiet horizontal discharge
  • Electric heat kit available as a field-installed option
  • AHRI Certified; UL Listed

Cabinet & durability features

  • Heavy-gauge galvanized-steel cabinet with Architectural Gray powder-paint finish
  • Louvered condenser coil protection
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Fully insulated blower compartment with convenient access panels
  • Meets cabinet air leakage requirements when tested in accordance with ASHRAE standard 193
  • One footprint for all tonnages
  • When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available)

Commonly used accessories (sold separately)

  • Downflow Economizer (use w/ PCCP roof curb): DDNECNJPCHHA
  • Downflow Plenum Kit (use w/ PCCP roof curb): PCP101-103
  • Downflow Plenum Kit (R-8) (use w/ PCCP roof curb): PCP101-103 R8
  • Elbow Flashing w/ R-8 Liner: PCEF101-103
  • Economizer Wiring Harness: 0259G00213
  • External Horizontal Filter Rack: DPHFRA
  • Horizontal Economizer: DHZECNJPGCHM
  • Inline Fuse Kit: INFKPKG01
  • Isolation Relay Kit (req'd with Economizer): IRKT-01
  • Manual Damper: PCMD101-103
  • Manual Damper - Horizontal: GPHMD101-103
  • Motorized Damper: PCMDM101-103
  • Outdoor Thermostat Kit w/ Lockout Stat: OT18-60A
  • Roof Curb: PCCP101-103
  • Square to Round Downflow (use w/ PCCP roof curb): SQRPC101 (small) / SQRPC102-103 (med/large)
  • Square to Round Horizontal: SQRPCH101 (small) / SQRPCH102-103 (med/large)

Common questions (answered)

  • Is this an all-in-one unit or split system? This is a packaged heat pump: the compressor, outdoor coil, indoor coil, and blower are all in one cabinet. It connects to your ductwork through the listed supply/return openings.
  • What does “horizontal discharge” mean? The condenser fan discharges air out the side of the unit (not straight up), which can matter for curb/roof installations, clearances, and sound/airflow planning.
  • What electrical service is required? 208-230 V, 1-phase, 60 Hz. Use a dedicated circuit sized to at least the MCA (18.03 A) with max overcurrent protection of 25 A. Always follow the unit nameplate and local code.
  • Does it include electric auxiliary heat? The heat pump section is factory-installed; electric heat is optional via a field-installed heat kit (sold separately).
  • What refrigerant does it use? R-32. R-32 is commonly classified as A2L (lower toxicity, mildly flammable), so installation and service must follow current safety codes and manufacturer instructions.
  • Will it fit my existing curb/duct? Compare the cabinet dimensions (66" W × 34" D × 30" H (overall B height); cabinet height A = 27.5") and duct openings (Supply 14" × 14" • Return 14" × 22") to your curb/transition. Accessories like roof curbs and square-to-round adapters are available (see list below).

Documentation & sources

  • Goodman series page: https://www.goodmanmfg.com/products/packaged-units/heat-pumps/gphh5-r-32
  • Goodman dealer spec sheet (PDF): https://www.goodmanmfg.com/docs/librariesprovider6/default-document-library/ss-gphh5-r32.pdf?view=true
  • A2L safety classification overview (ASHRAE): https://www.ashrae.org/file%20library/technical%20resources/bookstore/factsheet_ashrae_english_november2022.pdf
  • Google guidance used for this description: https://developers.google.com/search/docs/fundamentals/creating-helpful-content

Reminder: HVAC equipment should be selected using proper load calculations and installed/commissioned by qualified professionals. Capacities and sound levels are rated values and can vary with conditions and installation details.