This Goodman Dual Fuel System pairs the GZV6SA1810A variable-speed inverter-driven heat pump condenser with the CAPEA2418B3 evaporator coil and the GMVM970603BN 97% AFUE gas furnace for comprehensive year-round heating and cooling. Rated at 19 SEER2 and 8.8 HSPF2 for the heat pump side, and 60,000 BTU input on the furnace, this 1.5-ton R-32 system delivers efficient performance in both moderate and extreme cold conditions. The dual fuel design automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperatures, optimizing energy costs throughout the season. AHRI Certificate Number: 215488168. This is a communicating system, designed for seamless integration with the Goodman GTST connected thermostat and other Goodman communicating equipment for enhanced diagnostics and precise comfort control.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA1810A — Goodman 1.5-Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (19 SEER2 / 8.8 HSPF2 / 12 EER2)
- CAPEA2418B3 — Goodman Cased Upflow/Downflow Evaporator Coil with Internal EEV (17½" W x 21" D x 18" H, All-Aluminum, R-32 Optimized)
- GMVM970603BN — Goodman 97% AFUE 60,000 BTU Upflow/Horizontal Modulating Gas Furnace with Variable-Speed ECM Motor, Natural Gas
Pro-Installer Tip
Technical Friction: The GZV6SA1810A's 36⅝" width and side-discharge design means the condenser pad placement must account for both the discharge airflow clearance and the refrigerant line routing to the indoor coil. At 1.5 tons, the ¾" suction line and ⅜" liquid line are smaller than typical 2-ton-and-up systems — do not oversize line sets, as this causes oil return issues on the variable-speed compressor at low capacity stages.
Long-Term Prevention: After completing the final charge procedure per the installation manual (factory charge is for 15' of ⅜" liquid line), verify subcooling at 10±1°F and confirm the EEV in the indoor coil is cycling correctly through the communicating control board. A stuck or slow-responding EEV on initial startup will manifest as poor heating performance during the first cold snap, typically 4–8 months after a summer installation.
Expert Validation: Use a digital micron gauge to verify system evacuation to below 500 microns before charging — R-32's lower GWP does not reduce the importance of proper evacuation. The system's inverter drive board is sensitive to moisture contamination. Confirm the switchover temperature for dual fuel operation is programmed in the thermostat to optimize between heat pump COP and furnace gas cost in your region.
Professional Standard: R-32 refrigerant requires EPA Section 608 certification for handling. While R-32 has a lower GWP (675) compared to R-410A (2088), it is classified as A2L (mildly flammable) and requires compliance with ASHRAE 15 and local mechanical codes for charge limits in occupied spaces. Verify all flare connections with a calibrated torque wrench per the manufacturer's specified torque values.
Key Benefits
- High-Efficiency R-32 Refrigerant: R-32 has a Global Warming Potential (GWP) of 675, approximately 68% lower than R-410A (GWP 2088), reducing the system's direct environmental impact while maintaining equivalent cooling and heating performance at 19 SEER2 / 8.8 HSPF2.
- Variable-Speed Inverter Compressor: The swing compressor in the GZV6SA1810A modulates capacity from minimum to maximum output, reducing temperature swings, improving humidity control, and lowering energy consumption compared to single-speed or two-stage systems during partial-load conditions.
- Quiet Operation with Quiet Mode: Normal operating sound level of 61 dBA, with a three-level Quiet Mode that can reduce sound output to as low as 40 dBA — suitable for installations near bedrooms, patios, or property lines with noise ordinance concerns.
- Cold Climate Heat Pump Capability: ENERGY STAR® Cold Climate certified, the GZV6SA1810A operates in heating mode down to -10°F ambient, providing 13,000 BTU/h at 5°F outdoor temperature for reliable heat pump operation in northern climates without auxiliary heat dependency.
- Dual Fuel Cost Optimization: Automatically transitions between heat pump operation (higher COP at moderate temperatures) and gas furnace heating (more economical at extreme cold) based on a field-adjustable switchover temperature, delivering the lowest combined operating cost across the full heating season.
- Modulating Gas Furnace Technology: The 97% AFUE furnace features a modulating gas valve that adjusts flame intensity in fine increments, maximizing fuel efficiency and minimizing temperature fluctuations compared to single-stage or two-stage furnaces.
- Electronic Expansion Valve (EEV): The EEV provides continuous, precise refrigerant metering that adjusts in real-time to changing load conditions — a significant upgrade over fixed-orifice pistons or standard TXVs for maintaining optimal system efficiency across the full operating range.
Technical Specifications
| AHRI Certificate Number | 215488168 |
| Outdoor Unit — GZV6SA1810A | |
|---|---|
| Cooling Capacity (AHRI Rated) | 17,100 BTU/h |
| Heating Capacity @ 47°F (AHRI Rated) | 17,400 BTU/h |
| Heating Capacity @ 5°F | 13,000 BTU/h |
| SEER2 | 19.0 |
| EER2 | 12.0 |
| HSPF2 | 8.8 |
| Compressor Type | Variable-Speed Swing |
| Refrigerant | R-32 |
| Expansion Device | EEV |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| Min. Circuit Ampacity | 12.8A |
| Max. Overcurrent Protection | 15A |
| Dimensions (W x D x H) | 36⅝" x 13¾" x 27⅜" |
| Equipment Weight | 122 lbs |
| Sound Level (Cooling/Heating) | 61 / 61 dBA |
| Liquid / Suction Line | ⅜" / ¾" |
| Factory Refrigerant Charge | 74 oz |
| Evaporator Coil — CAPEA2418B3 | |
| Configuration | Upflow/Downflow, Cased |
| Cabinet Dimensions (W x D x H) | 17½" x 21" x 18" |
| Nominal Capacity | 2 Ton |
| Ship Weight | 43 lbs |
| Gas Furnace — GMVM970603BN | |
| AFUE | 97% |
| BTU Input | 60,000 BTU/h |
| Configuration | Upflow/Horizontal |
| Gas Valve | Modulating |
| Blower Motor | Variable-Speed ECM |
| Cabinet Width | 17½" |
| Emissions | Natural Gas |
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.
Compliance & Environmental Data
| Refrigerant Type | R-32 |
| Refrigerant GWP | 675 (approximately 68% lower than R-410A) |
| Refrigerant Safety Classification | A2L (Mildly Flammable) |
| EPA 608 Certification Required | Yes — Required for purchase, handling, and servicing |
| AHRI Certified | Yes — Certificate #215488168 |
| ENERGY STAR® Certified | Cold Climate Certified |
| Regional Compliance | Meets DOE 2023 regional efficiency standards for all U.S. regions |
| ASHRAE 15 Compliance | Required — Charge limits apply for A2L refrigerant in occupied spaces |
| Emissions Compliance | Standard Natural Gas emissions |
| Federal Tax Credit Eligibility | This system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a qualified tax professional and visit energystar.gov for current eligibility requirements. |
Warranty & Registration
-
Outdoor Unit (GZV6SA1810A) Warranty:
- Unregistered: 5-Year Parts Limited Warranty
- Registered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty
- Compressor: If the compressor fails within the first 10 years (registered unit), Goodman will furnish a new equivalent replacement unit at no charge (one-time)
- Optional: One-time compressor replacement coverage for years 11–99 available through an ASURE Extend Service Plan
-
Evaporator Coil (CAPEA2418B3) Warranty:
- Unregistered: 5-Year Parts Limited Warranty
- Registered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty
-
Gas Furnace (GMVM970603BN) Warranty:
- Unregistered: 20-Year Heat Exchanger Limited Warranty + 5-Year All Other Parts Limited Warranty
- Registered (within 60 days of installation at goodmanmfg.com): Lifetime Heat Exchanger Limited Warranty (up to 99 years) + 10-Year Parts Limited Warranty + 10-Year Unit Replacement Limited Warranty (heat exchanger failure)
- If the heat exchanger fails within the first 10 years (registered unit), Goodman will furnish a new equivalent replacement unit at no charge (one-time)
Important: Online registration must be completed within 60 days of installation to receive the full extended warranty coverage. Registration is not required in California, Florida, or Québec. Warranty durations in Texas and Florida may differ. All warranties apply to owner-occupied residential installations only. Complete warranty details are available at goodmanmfg.com.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...