This AHRI-certified Goodman 3.5-ton Dual Fuel System (AHRI Ref. #215488264) pairs the GZV6SA4210 variable-speed, inverter-driven R-32 heat pump condenser with the CAPEA4830C3 evaporator coil and the GMVC800804CN 80% AFUE gas furnace. Rated at 17.0 SEER2 and 8.0 HSPF2 for the heat pump portion, this dual fuel configuration automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature to optimize both comfort and operating cost. The system delivers up to 40,000 BTU/h in combined heating capacity and uses R-32 refrigerant (GWP 675), a lower-GWP alternative to R-410A that supports evolving EPA regulations.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA4210 — Goodman 3.5-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (37"W x 12⅝"D x 39"H, 168 lbs)
- CAPEA4830C3 — Goodman Upflow/Downflow Cased Evaporator Coil with Electronic Expansion Valve (EEV), All-Aluminum Coil, R-32 Optimized (21" x 21" x 30", 68 lbs)
- GMVC800804CN — Goodman 80% AFUE Upflow/Horizontal Two-Stage Gas Furnace, 80,000 BTU/h Input, Variable-Speed ECM, ComfortBridge™ Communicating, Natural Gas (21" x 28" x 33⅜", 118 lbs)
Pro-Installer Tip
Technical Friction: Dual fuel systems with R-32 require careful attention to the changeover balance point. The GZV6S variable-speed heat pump operates efficiently down to -10°F ambient, but the switchover to the GMVC800804CN furnace must be programmed based on the regional utility rate crossover — not just outdoor temperature. In communicating mode, only two low-voltage wires run to the outdoor unit, but confirm the indoor coil's EEV wiring harness is properly seated before commissioning.
Long-Term Prevention: After initial startup, verify subcooling at the service valve reads 8±1°F per the GZV6S specification for this tonnage. Out-of-spec subcooling on day one creates compressor bearing wear that shows up as a warranty call at month 14. Install a field bi-flow filter drier (included) on the liquid line and pull the system to 350 microns or below before releasing the 100 oz factory charge.
Expert Validation: Use a digital manifold gauge with R-32 PT charts (Testo 557s or equivalent) to confirm operating pressures. R-32 operates at approximately 15% higher discharge pressures than R-410A — standard gauge sets without updated scales will give misleading readings. Verify superheat is in auto-control mode via the seven-segment LED display on the outdoor unit control board.
Professional Standard: R-32 is classified as A2L (mildly flammable). EPA Section 608 certification is required for handling. Ensure the installation meets the latest edition of ASHRAE 15 and UL 60335-2-40 charge-size limits for the installed space. For California installations with Natural Gas furnaces, confirm SCAQMD district compliance before commissioning the gas furnace portion.
Key System Benefits
- Dual Fuel Efficiency: Automatically transitions between the 17.0 SEER2 / 8.0 HSPF2 heat pump and the 80% AFUE gas furnace at the programmed balance point, optimizing energy cost across all outdoor conditions from -10°F to 115°F.
- Variable-Speed Comfort: The GZV6S inverter-driven swing compressor and the furnace's variable-speed ECM blower work together to deliver precise temperature control and reduced temperature swings compared to single-speed systems.
- Lower-GWP Refrigerant: R-32 (GWP 675) reduces the system's direct environmental impact by approximately 68% compared to equivalent R-410A systems (GWP 2,088), aligning with EPA AIM Act phase-down requirements.
- Quiet Operation: The outdoor unit features a high-density compressor sound blanket, digitally commutated fan motor, and field-selectable Quiet Mode with up to three sound levels (as low as 45 dBA).
- All-Aluminum Indoor Coil: The CAPEA4830C3 evaporator coil features an all-aluminum construction optimized for R-32, eliminating galvanic corrosion between dissimilar metals and improving long-term reliability.
- ComfortBridge™ Communicating: The GMVC800804CN furnace supports ComfortBridge™ technology with Bluetooth commissioning via the CoolCloud app, enabling diagnostic monitoring, auto-configuration, and two-wire connectivity to the outdoor unit.
Technical Specifications
| Specification | Value |
|---|---|
| System Type | Dual Fuel System |
| AHRI Certificate Number | 215488264 |
| Nominal System Capacity | 3.5 Tons |
| SEER2 | 17.0 |
| HSPF2 | 8.0 |
| Refrigerant | R-32 |
| Factory Charge | 100 oz |
| Outdoor Unit — GZV6SA4210 | |
| Max Cooling Capacity (95°F) | 41,000 BTU/h |
| Max Heating Capacity (47°F) | 40,000 BTU/h |
| Max Heating Capacity (5°F) | 27,400 BTU/h |
| Compressor Type | Variable-Speed Swing |
| Expansion Device | EEV |
| Outdoor Unit Dimensions (W x D x H) | 37"W x 12⅝"D x 39"H |
| Outdoor Unit Weight | 168 lbs |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| Min. Circuit Ampacity | 31.8 A |
| Max Overcurrent Protection | 35 A |
| Liquid Line | ⅜" O.D. |
| Suction Line | 1⅛" O.D. |
| Indoor Coil — CAPEA4830C3 | |
| Coil Configuration | Upflow/Downflow, Cased |
| Coil Expansion Device | EEV |
| Coil Dimensions (W x D x H) | 21" x 21" x 30" |
| Coil Ship Weight | 68 lbs |
| Gas Furnace — GMVC800804CN | |
| AFUE | 80% |
| High Fire Input | 80,000 BTU/h |
| High Fire Output (est.) | 64,000 BTU/h |
| Furnace Configuration | Upflow/Horizontal |
| Gas Valve | Two-Stage |
| Blower Motor | Variable-Speed ECM |
| Emissions | Natural Gas |
| Furnace Dimensions (W x D x H) | 21" x 28" x 33⅜" |
| Furnace Ship Weight | 118 lbs |
| Furnace Electrical | 115V / 1 Phase / 60 Hz |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Refrigerant GWP | 675 (vs. 2,088 for R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 | Certification required for handling R-32; subject to AIM Act HFC phase-down |
| AHRI Certified | Yes — Certificate #215488264 |
| ETL Listed | Yes |
| Regional Compliance | All Regions (verify local A2L refrigerant adoption status) |
| Emissions Compliance | Standard NOx — not rated for California SCAQMD districts |
| Federal Tax Credit (25C) | The heat pump component (SEER2 17.0 / HSPF2 8.0) may qualify for federal energy efficiency tax credits under IRS Section 25C for heat pumps meeting SEER2 ≥ 16 and HSPF2 ≥ 8. Verify current limits at energystar.gov. |
Warranty & Registration
Outdoor Unit (GZV6SA4210) — Heat Pump Condenser:
- Unregistered: 5-Year Parts Limited Warranty from installation date.
- Registered (within 60 days of installation): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (good for as long as the original registered owner occupies the home, up to 10 years). If the compressor or outdoor unit fails during the registered warranty period, Goodman will furnish a replacement unit at no charge for the unit (labor not included).
- Registration: www.goodmanmfg.com → Product Registration within 60 days of installation.
- Online registration is not required in California, Florida, or Québec.
Evaporator Coil (CAPEA4830C3):
- Unregistered: 5-Year Parts Limited Warranty from installation date.
- Registered (within 60 days of installation): 10-Year Parts Limited Warranty.
- Registration: www.goodmanmfg.com → Product Registration within 60 days of installation.
Gas Furnace (GMVC800804CN):
- Unregistered: 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty from installation date.
- Registered (within 60 days of installation): Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns and resides in the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. If the heat exchanger fails within the first 10 years, Goodman will furnish a complete replacement furnace. The heat exchanger is warranted for years 11–99 after installation for registered owners.
- Registration: www.goodmanmfg.com → Product Registration within 60 days of installation.
Important: All warranty coverage requires installation by a licensed contractor in an owner-occupied residence. Units ordered online must be installed by a dealer adhering to all applicable codes. Labor, refrigerant, freight, and associated service costs are not covered under any warranty tier. Warranty terms may differ in Texas and Florida. See complete warranty documents for full terms, limitations, and exclusions.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...