Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 3.5 Ton 14.3 SEER2 R-32 Heat Pump Condenser and Evaporator Coil System | GZV6SA4210 + CAPEA6030C3 | 21" Cabinet Width Upflow/Downflow Cased Coil

SKU: GZV6SA4210-CAPEA6030C3
Your Price:
$4,575.00 $5,627.00
You Save: $1,052.00 19%
Checkout Secure

Quantity Remaining:

149 of 200 Sold
Order in the next to get it by

This AHRI-certified Goodman 3.5-ton Heat Pump Condenser and Evaporator Coil System (AHRI Ref. #217577957) pairs the GZV6SA4210 variable-speed, inverter-driven R-32 heat pump condenser with the CAPEA6030C3 cased evaporator coil. Rated at 14.3 SEER2 and 7.7 HSPF2, this system provides both cooling and heating capability in a single outdoor-indoor combination. The system delivers up to 41,000 BTU/h in cooling and up to 39,500 BTU/h in heating at 47°F, using R-32 refrigerant (GWP 675), a lower-GWP alternative to R-410A.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA4210 — Goodman 3.5-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (37"W x 12⅝"D x 39"H, 168 lbs)
  • CAPEA6030C3 — Goodman Upflow/Downflow Cased Evaporator Coil with Electronic Expansion Valve (EEV), All-Aluminum Coil, R-32 Optimized (21" x 21" x 30", 75 lbs)

Pro-Installer Tip

Technical Friction: The GZV6SA4210 heat pump condenser paired with the CAPEA6030C3 coil uses R-32 refrigerant with an EEV-controlled expansion device. The coil's R-32 sensor is designed for the life span of the coil, but during initial installation, verify the EEV wiring harness connection to the coil control board is fully seated — a loose pin here causes intermittent superheat faults that are difficult to diagnose later.

Long-Term Prevention: Pull the system to 350 microns or below before releasing the factory charge. R-32's lower molecular weight means it finds leaks standard nitrogen testing might miss. Confirm subcooling reads 8±1°F at the outdoor service valve after a 15-minute stabilization period at 95°F ambient equivalent load.

Expert Validation: Use a digital manifold with R-32 pressure-temperature charts. R-32 operates at approximately 15% higher discharge pressures than R-410A. Verify the seven-segment LED on the outdoor unit shows no active fault codes and superheat is in auto-control mode.

Professional Standard: R-32 is classified as A2L (mildly flammable) under ASHRAE 34. EPA Section 608 certification is required. Ensure installation complies with ASHRAE 15, UL 60335-2-40, and all local mechanical codes regarding A2L refrigerant charge limits for the installed space volume.

Key System Benefits

  • High-Efficiency Heat Pump Operation: At 14.3 SEER2 and 7.7 HSPF2, this system delivers year-round heating and cooling from a single outdoor unit, operating efficiently from -10°F to 115°F ambient.
  • Variable-Speed Inverter Technology: The GZV6S swing compressor modulates capacity continuously rather than cycling on/off, providing precise temperature control, lower sound levels, and reduced energy consumption at part-load conditions.
  • Lower-GWP Refrigerant: R-32 (GWP 675) reduces the system's direct environmental impact by approximately 68% compared to equivalent R-410A systems (GWP 2,088).
  • Quiet Operation: High-density compressor sound blanket and field-selectable Quiet Mode with up to three sound levels (as low as 45 dBA) make this unit suitable for noise-sensitive installations.
  • All-Aluminum EEV Coil: The CAPEA6030C3 features all-aluminum construction with factory-installed electronic expansion valve (EEV) for precise refrigerant metering, R-32 sensor, and 21" depth for attic access compatibility.

Technical Specifications

Specification Value
System Type Heat Pump Condenser and Evaporator Coil System
AHRI Certificate Number 217577957
Nominal System Capacity 3.5 Tons
SEER2 14.3
HSPF2 7.7
Refrigerant R-32
Factory Charge 100 oz
Outdoor Unit — GZV6SA4210
Max Cooling Capacity (95°F) 41,000 BTU/h
Max Heating Capacity (47°F) 40,000 BTU/h
Max Heating Capacity (5°F) 27,400 BTU/h
Compressor Type Variable-Speed Swing
Expansion Device EEV
Outdoor Unit Dimensions (W x D x H) 37"W x 12⅝"D x 39"H
Outdoor Unit Weight 168 lbs
Electrical 208-230V / 1 Phase / 60 Hz
Min. Circuit Ampacity 31.8 A
Max Overcurrent Protection 35 A
Liquid Line ⅜" O.D.
Suction Line 1⅛" O.D.
Indoor Coil — CAPEA6030C3
Coil Configuration Upflow/Downflow, Cased
Coil Expansion Device EEV
Coil Dimensions (W x D x H) 21" x 21" x 30"
Coil Ship Weight 75 lbs
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane)
Refrigerant GWP 675 (vs. 2,088 for R-410A)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Certification required for handling R-32; subject to AIM Act HFC phase-down
AHRI Certified Yes — Certificate #217577957
ETL Listed Yes
Regional Compliance All Regions (verify local A2L refrigerant adoption status)
Federal Tax Credit (25C) Verify eligibility at energystar.gov — tax credit requirements are subject to change.

Warranty & Registration

Outdoor Unit (GZV6SA4210) — Heat Pump Condenser:

  • Unregistered: 5-Year Parts Limited Warranty from installation date.
  • Registered (within 60 days of installation): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (good for as long as the original registered owner occupies the home, up to 10 years). If the compressor or outdoor unit fails during the registered warranty period, Goodman will furnish a replacement unit at no charge for the unit (labor not included).
  • Registration: www.goodmanmfg.com → Product Registration within 60 days of installation.
  • Online registration is not required in California, Florida, or Québec.

Evaporator Coil (CAPEA6030C3):

  • Unregistered: 5-Year Parts Limited Warranty from installation date.
  • Registered (within 60 days of installation): 10-Year Parts Limited Warranty.
  • Registration: www.goodmanmfg.com → Product Registration within 60 days of installation.

Important: All warranty coverage requires installation by a licensed contractor in an owner-occupied residence. Units ordered online must be installed by a dealer adhering to all applicable codes. Labor, refrigerant, freight, and associated service costs are not covered under any warranty tier. Warranty terms may differ in Texas and Florida. See complete warranty documents for full terms, limitations, and exclusions.