Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman | 4 Ton | 17.0 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil & Modular Blower | GZV7SA4810 | CAPEA6030C3 | MBVK16CP1X00 | 21" Upflow/Downflow Coil | 21" Multi-Positional Modular Blower

SKU: GZV7SA4810-CAPEA6030C3-MBVK16CP1X00-215433959
Your Price:
$6,562.00 $7,874.00
You Save: $1,312.00 17%
Checkout Secure

Quantity Remaining:

401 of 500 Sold
Order in the next to get it by

This Goodman 4-Ton system pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump with the CAPEA6030C3 evaporator coil and MBVK16CP1X00 modular blower. AHRI certified under #215433959, this configuration delivers up to 17.0 SEER2 and 8.8 HSPF2.

This system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.

R-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV7SA4810 — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU/h cooling and 47,500 BTU/h heating at 47°F.
  • CAPEA6030C3 — Goodman CAPEA Series Cased Upflow/Downflow Evaporator Coil with factory-installed EEV. All-aluminum coil optimized for R-32. Cabinet width: 21"; depth: 21"".
  • MBVK16CP1X00 — Goodman MBVK Series Multi-Position Variable-Speed ECM Modular Blower. 1600 CFM capacity with communicating controls. Cabinet: 21" W × 21" D × 30" H.

Pro-Installer Tip

Technical Friction: When connecting the CAPEA6030C3 coil to the GZV7SA4810 outdoor unit, note the suction valve is ⅞" while the required suction line is 1⅛" — ⅞" to 1⅛" adapters are required. In horizontal attic installations, the 21" coil depth fits standard joist bays, but confirm clearance for the control box access panel.

Long-Term Prevention: With EEV metering on both the outdoor unit and indoor coil, the system self-adjusts superheat — but this depends on clean sensor readings. Wrap the coil temperature sensor securely and protect it from contact with the drain pan to prevent erratic EEV behavior that causes short-cycling complaints months after installation.

Expert Validation: Pull the system down below 500 microns and hold for 10+ minutes on a digital micron gauge. Verify subcooling at the service valve reads 9±1°F. The unit ships charged for 15 feet of ⅜" liquid line — adjust charge per the installation manual for longer runs.

Professional Standard: R-32 is classified A2L under ASHRAE 34. EPA Section 608 certification is required, and local codes may require refrigerant detection in confined mechanical rooms. Ensure the outdoor unit has proper clearance from property lines for sound compliance (73 dBA at normal mode).

Key Benefits

  • Up to 17.0 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.
  • R-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.
  • Variable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.
  • ENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.
  • Quiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.

Technical Specifications

AHRI-Certified System Ratings
AHRI Certificate Number 215433959
SEER2 17.0
EER2 10.0
HSPF2 8.8
Cooling Capacity (M1) 45,500 BTU/h
Heating Capacity – High (M1) @ 47°F 47,000 BTU/h
Heating Capacity @ 5°F 29,000 BTU/h
Outdoor Unit — GZV7SA4810
Dimensions (W × D × H) 37" × 12⅝" × 39"
Equipment Weight 179 lbs
Electrical 208-230/1/60Hz
Min. Circuit Ampacity (MCA) 37.5A
Max. Overcurrent Protection (MOCP) 40A
Refrigerant Charge 118 oz R-32
Liquid Line Size ⅜"
Suction Line Size 1⅛"
Sound Rating (Cooling/Heating) 73/73 dBA (Sound Power)
Compressor Type Variable-Speed Swing
Expansion Device EEV
Evaporator Coil — CAPEA6030C3
Cabinet Dimensions (W × D × H) 21" × 21" × 30"
Configuration Upflow/Downflow (Cased)
Modular Blower — MBVK16CP1X00
Cabinet Dimensions (W × D × H) 21" × 21" × 30"
Motor Variable-Speed ECM (¾ HP)
CFM Rating 1600 CFM
Ship Weight 80 lbs
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.
Compliance & Environmental Data
Refrigerant R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (67.5% lower than R-410A)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Technician certification required for handling R-32
AIM Act Compliance Meets HFC phase-down requirements
ENERGY STAR® Most Efficient / Cold Climate Heat Pump
Tax Credit Eligibility May qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier
Regional Compliance Meets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.

Warranty & Registration

  • Outdoor Unit (GZV7SA4810): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.
  • Evaporator Coil (CAPEA6030C3): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.
  • Modular Blower (MBVK16CP1X00): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.
  • Registration Deadline: Online registration must be completed within 60 days of installation at www.goodmanmfg.com. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.
  • Important: All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.