This Goodman 4-Ton system pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump with the CAPEA6030D3 evaporator coil and MBVK16CP1X00 modular blower. AHRI certified under #215433959, this configuration delivers up to 17.0 SEER2 and 8.8 HSPF2.
This system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.
R-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV7SA4810 — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU/h cooling and 47,500 BTU/h heating at 47°F.
- CAPEA6030D3 — Goodman CAPEA Series Cased Upflow/Downflow Evaporator Coil with factory-installed EEV. All-aluminum coil optimized for R-32. Cabinet width: 24½"; depth: 21"".
- MBVK16CP1X00 — Goodman MBVK Series Multi-Position Variable-Speed ECM Modular Blower. 1600 CFM capacity with communicating controls. Cabinet: 21" W × 21" D × 30" H.
Pro-Installer Tip
Technical Friction: When connecting the CAPEA6030D3 coil to the GZV7SA4810 outdoor unit, note the suction valve is ⅞" while the required suction line is 1⅛" — ⅞" to 1⅛" adapters are required. In horizontal attic installations, the 21" coil depth fits standard joist bays, but confirm clearance for the control box access panel.
Long-Term Prevention: With EEV metering on both the outdoor unit and indoor coil, the system self-adjusts superheat — but this depends on clean sensor readings. Wrap the coil temperature sensor securely and protect it from contact with the drain pan to prevent erratic EEV behavior that causes short-cycling complaints months after installation.
Expert Validation: Pull the system down below 500 microns and hold for 10+ minutes on a digital micron gauge. Verify subcooling at the service valve reads 9±1°F. The unit ships charged for 15 feet of ⅜" liquid line — adjust charge per the installation manual for longer runs.
Professional Standard: R-32 is classified A2L under ASHRAE 34. EPA Section 608 certification is required, and local codes may require refrigerant detection in confined mechanical rooms. Ensure the outdoor unit has proper clearance from property lines for sound compliance (73 dBA at normal mode).
Key Benefits
- Up to 17.0 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.
- R-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.
- Variable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.
- ENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.
- Quiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.
Technical Specifications
| AHRI-Certified System Ratings | |
|---|---|
| AHRI Certificate Number | 215433959 |
| SEER2 | 17.0 |
| EER2 | 10.0 |
| HSPF2 | 8.8 |
| Cooling Capacity (M1) | 45,500 BTU/h |
| Heating Capacity – High (M1) @ 47°F | 47,000 BTU/h |
| Heating Capacity @ 5°F | 29,000 BTU/h |
| Outdoor Unit — GZV7SA4810 | |
| Dimensions (W × D × H) | 37" × 12⅝" × 39" |
| Equipment Weight | 179 lbs |
| Electrical | 208-230/1/60Hz |
| Min. Circuit Ampacity (MCA) | 37.5A |
| Max. Overcurrent Protection (MOCP) | 40A |
| Refrigerant Charge | 118 oz R-32 |
| Liquid Line Size | ⅜" |
| Suction Line Size | 1⅛" |
| Sound Rating (Cooling/Heating) | 73/73 dBA (Sound Power) |
| Compressor Type | Variable-Speed Swing |
| Expansion Device | EEV |
| Evaporator Coil — CAPEA6030D3 | |
| Cabinet Dimensions (W × D × H) | 24½" × 21" × 30" |
| Configuration | Upflow/Downflow (Cased) |
| Modular Blower — MBVK16CP1X00 | |
| Cabinet Dimensions (W × D × H) | 21" × 21" × 30" |
| Motor | Variable-Speed ECM (¾ HP) |
| CFM Rating | 1600 CFM |
| Ship Weight | 80 lbs |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
| Compliance & Environmental Data | |
|---|---|
| Refrigerant | R-32 (Difluoromethane) |
| Global Warming Potential (GWP) | 675 (67.5% lower than R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 | Technician certification required for handling R-32 |
| AIM Act Compliance | Meets HFC phase-down requirements |
| ENERGY STAR® | Most Efficient / Cold Climate Heat Pump |
| Tax Credit Eligibility | May qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier |
| Regional Compliance | Meets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements. |
Warranty & Registration
- Outdoor Unit (GZV7SA4810): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.
- Evaporator Coil (CAPEA6030D3): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.
- Modular Blower (MBVK16CP1X00): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.
- Registration Deadline: Online registration must be completed within 60 days of installation at www.goodmanmfg.com. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.
- Important: All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...