This Goodman 2-Ton 18.2 SEER2 / 9.0 HSPF2 Dual Fuel System pairs the GZV9S-series inverter-driven variable-speed heat pump condenser (Model: GZV9SA241C) with a 80,000 BTU 97% AFUE Modulating gas furnace (Model: GRVM970804CN) and a cased horizontal evaporator coil (Model: CHPEA4830D3). This AHRI-certified matched system (Certificate #: 216699909) uses R-32 refrigerant and is ENERGY STAR® certified. The dual fuel configuration provides efficient electric heat pump operation down to -20°F, with automatic switchover to gas heating when temperatures or load conditions favor combustion.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV9SA241C – Goodman GZV9S-Series 2-Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser, Side Discharge, up to 21.0 SEER2 / 10.0 HSPF2, 208-230V/1Ph/60Hz, EEV Expansion Device
- GRVM970804CN – Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed Modulating ECM Gas Furnace, Upflow/Horizontal Configuration, Natural Gas, 115V/1Ph/60Hz
- CHPEA4830D3 – Goodman CHPEA-Series 2-Ton Cased Horizontal Indoor Coil with Internal EEV, R-32 Optimized, All-Aluminum Evaporator, 30" W x 21" D x 24½" H
Pro-Installer Tip: Dual Fuel Changeover Optimization
The Technical Friction: The GZV9S outdoor unit ships with 162 oz. of R-32 charge, factory-set for 15 feet of ⅜" liquid line. In dual fuel configurations, the changeover balance point between heat pump and gas furnace operation is critical. If the balance point is set too high, the system defaults to gas unnecessarily; too low, and the heat pump runs inefficiently in extreme cold, increasing compressor wear and energy costs.
The Long-Term Prevention: After completing the final charge procedure per the installation manual, verify subcooling at the service valve reads 11±1°F. Document the outdoor ambient and superheat readings during commissioning. This baseline data prevents nuisance “no heat” service calls 6–12 months later when homeowners first experience the changeover during cold snaps.
The Expert Validation: Use a quality digital manifold gauge set with R-32 PT tables loaded (e.g., Testo 570s or Fieldpiece SM480V) to confirm EEV superheat is in auto-control range. The GZV9S EEV is self-regulating, but confirming the charge with weigh-in method plus subcooling verification ensures the system operates within design parameters.
The Professional Standard: R-32 is an A2L (mildly flammable) refrigerant. EPA Section 608 certification is required for handling. Verify the installation complies with UL 60335-2-40 requirements and all local mechanical codes regarding A2L refrigerant charge limits in enclosed spaces. Confirm the R-32 sensor integrated into the indoor coil is operational before system handoff.
Key Benefits
- High-Efficiency Rated Performance: This matched system achieves up to 18.2 SEER2 and 9.0 HSPF2, verified under AHRI Certificate #216699909. The variable-speed inverter compressor modulates capacity to match the load, reducing energy waste compared to fixed-speed systems.
- Low-GWP R-32 Refrigerant: R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2,088). This aligns with EPA AIM Act phase-down requirements and positions the system for long-term refrigerant availability.
- Dual Fuel Versatility: The heat pump provides efficient electric heating down to -20°F ambient, while the 80,000 BTU 97% AFUE gas furnace serves as a backup for extreme cold or high-demand conditions. This configuration often qualifies for utility rebates in regions with time-of-use electricity rates.
- Quiet Operation: The GZV9S outdoor unit operates at 71 dBA in normal cooling mode, with a selectable Quiet Mode that can reduce sound output to as low as 45 dBA — suitable for installations near bedrooms or property lines with noise ordinance constraints.
- All-Aluminum Evaporator Coil: The indoor coil uses an all-aluminum construction that eliminates galvanic corrosion between dissimilar metals, a known failure point in copper-aluminum coils exposed to high-humidity or coastal environments.
- 21” Cabinet Depth: Both the indoor coil and blower/air handler sections use a 21” depth cabinet, which fits through standard 22” attic access openings without requiring disassembly — reducing installation time and potential for field damage.
Technical Specifications
| Specification | Value |
|---|---|
| AHRI Certificate Number | 216699909 |
| System SEER2 | 18.2 |
| System HSPF2 | 9.0 |
| System Capacity | 2 Ton |
| Refrigerant | R-32 |
| Outdoor Unit Max Cooling (BTU/h @ 95°F) | 24,000 |
| Outdoor Unit Max Heating (BTU/h @ 47°F) | 24,000 |
| Outdoor Unit Max Heating (BTU/h @ 5°F) | 24,000 |
| System Heating Capacity (M1 BTU/h) | 21,000 |
| Furnace Input (BTU/h) | 80,000 |
| Furnace AFUE | 97% |
| Outdoor Unit Dimensions (W x D x H) | 37" W x 12⅝" D x 56⁵⁄₁₆" H |
| Outdoor Unit Weight (Equipment) | 230 lbs |
| Outdoor Unit Sound (Cooling/Heating dBA) | 71 / 75 |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Voltage (Outdoor Unit) | 208-230V / 1Ph / 60Hz |
| Coil-to-Furnace Fit | 1.75 |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental
| Category | Detail |
|---|---|
| Refrigerant Type | R-32 (A2L – Mildly Flammable) |
| Refrigerant GWP | 675 (vs. R-410A at 2,088) |
| EPA 608 Certification | Required for handling R-32 refrigerant |
| Safety Standard | UL 60335-2-40 Compliant |
| ENERGY STAR® | Certified |
| AHRI Certified | Yes – Certificate #{ahri} |
| Federal Tax Credit Eligibility | Consult a qualified tax advisor. Heat pump systems meeting CEE Tier requirements and installed by a qualified contractor may be eligible for federal tax credits under the Inflation Reduction Act (IRA) §25C, up to $2,000. |
| Emissions Compliance (Furnace) | Natural Gas |
Warranty & Registration
Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies Manufacturing, L.P. Online registration must be completed within 60 days of installation at www.goodmanmfg.com to receive the full warranty benefits. Details by component:
- Outdoor Unit (GZV9SA241C): If not registered: 5-Year Parts Limited Warranty. If registered within 60 days: 10-Year Parts Limited Warranty (for as long as the original registered owner resides in the home). Compressor failure within the first 10 years on a registered unit qualifies for a one-time full unit replacement. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.
- Gas Furnace (GRVM970804CN): If not registered: 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty. If registered within 60 days: 20-Year Heat Exchanger Limited Warranty and 10-Year Parts Limited Warranty (for as long as the original registered owner resides in the home).
- Evaporator Coil (CHPEA4830D3): If not registered: 5-Year Parts Limited Warranty. If registered within 60 days: 10-Year Parts Limited Warranty. Online registration must be completed within 60 days of installation.
Note: Online registration is not required in California, Florida, or Québec. Warranty durations in Texas and Florida may differ. See complete warranty documents for full terms, limitations, and exclusions.
Let customers speak for us
What customers think about the store
Store offers excellent customer service with fast shipping and competitive pricing. Products arrive well-packaged and on time. Knowledgeable support staff assist with installations and technical questions. Customers appreciate quality HVAC systems, mini-splits...