This Goodman 5-Ton Dual Fuel System delivers up to 16.0 SEER2 and 8.5 HSPF2 efficiency ratings using low-GWP R-32 refrigerant.
The dual fuel configuration pairs the GZV9S variable-speed inverter heat pump with a two-stage, 96% AFUE gas furnace, providing automatic switchover between electric heat pump and gas heating for optimized comfort and energy savings in all climate zones.
AHRI Certified (Certificate #: 218003043). ENERGY STAR® Cold Climate Certified.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV9SA6010 — Goodman GZV9S 5-Ton Variable-Speed Inverter Driven R-32 Side-Discharge Heat Pump Condenser (Up to 21.0 SEER2 / 10.0 HSPF2), 208-230V/1Ph/60Hz, 230 lbs
- GCVC961205DN — Goodman Two-Stage 96% AFUE 120,000 BTU/h Gas Furnace, Variable-Speed Communicating ECM, Downflow/Horizontal, Natural Gas, Communicating
- CAPEA6030D3 — Goodman Upflow/Downflow Cased Evaporator Coil with Internal EEV, 24½" Cabinet Width, 21" Depth, All-Aluminum, R-32 Optimized
Pro-Installer Tip
Technical Friction: On 5-ton dual fuel systems with R-32, the GZV9S outdoor unit requires ⅞" to 1⅛" suction line adapters at the service valve. If the furnace is in a tight closet or alcove, verify that the combined coil-on-furnace stack height clears the ceiling by the code-required service access minimum before committing to the installation position.
Long-Term Prevention: After evacuation, hold a standing vacuum below 500 microns for a minimum of 10 minutes using a Fieldpiece SVG3 or equivalent digital micron gauge. R-32 is less forgiving of moisture contamination than R-410A; residual moisture in the lineset will form acids that degrade compressor windings within 12–18 months, leading to a nuisance compressor fault code well before the warranty period expires.
Expert Validation: Use a digital torque wrench (e.g., Ritchie Yellow Jacket 60648) calibrated to the flare nut specifications in the GZV9S installation manual. Over- or under-torqued flare connections are the #1 root cause of slow R-32 leaks flagged by the unit's onboard pressure transducer diagnostics.
Professional Standard: R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE Standard 34. Verify local AHJ adoption of 2024 UMC/IMC codes for A2L allowances. In California SCAQMD jurisdictions, confirm the furnace NOx rating meets the applicable ng/J standard before the final inspection.
Key Benefits
- High-Efficiency Operation: Up to 16.0 SEER2 / 8.5 HSPF2 ratings reduce annual energy consumption compared to standard-efficiency systems, potentially qualifying for federal tax credits and utility rebates.
- Low-GWP R-32 Refrigerant: R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088)—reducing the system's direct environmental impact while maintaining thermodynamic performance.
- Variable-Speed Inverter Compressor: The GZV9S swing compressor modulates output to match real-time load conditions, minimizing temperature swings and reducing cycling losses compared to single- or two-stage compressors.
- Dual Fuel Flexibility: Automatic switchover between electric heat pump and gas furnace operation based on outdoor temperature provides optimized heating efficiency across a wide ambient range (-20°F to 70°F for heat pump mode).
- Quiet Operation: Quiet-mode feature offers up to 3 selectable sound levels (as low as 45 dBA) on the outdoor unit, suitable for installations near bedrooms, patios, or property-line-adjacent locations.
- ENERGY STAR® Cold Climate Certified: Meets or exceeds ENERGY STAR Cold Climate heat pump criteria, validating heating performance in sub-freezing conditions down to -20°F ambient.
Technical Specifications
| Specification | Value |
|---|---|
| AHRI Certificate Number | 218003043 |
| System Type | Dual Fuel System |
| Nominal System Capacity | 5 Ton (60,000 BTU/h Nominal) |
| SEER2 | 16.0 |
| HSPF2 | 8.5 |
| AFUE (Furnace) | 96% |
| Refrigerant Type | R-32 (A2L, Low-GWP) |
| Outdoor Unit Model | GZV9SA6010 |
| Outdoor Unit Weight | 230 lbs (Ship: 265 lbs) |
| Outdoor Electrical | 208-230/1, 60 Hz |
| Outdoor MCA / MOP | 34.4A / 40A |
| Max Cooling Capacity (95°F) | 54,000 BTU/h |
| Max Heating Capacity (47°F) | 54,000 BTU/h |
| Max Heating Capacity (5°F) | 47,000 BTU/h |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Liquid Line / Suction Line | ⅜" / 1⅛" |
| Factory Refrigerant Charge | 162 oz. (for 15 ft of ⅜" liquid line) |
| Furnace Model | GCVC961205DN |
| Furnace Heating Input | 120,000 BTU/h |
| Furnace AFUE | 96% |
| Furnace Stage / Motor | Two-Stage / Variable-Speed Communicating ECM |
| Furnace Configuration | Downflow/Horizontal |
| Furnace NOx / Gas Type | Natural Gas |
| Furnace Heating Output (M1) | 53,500 BTU/h |
| Evaporator Coil Model | CAPEA6030D3 |
| Coil Configuration | Upflow/Downflow (Cased) |
| Coil Cabinet Dimensions (W x D x H) | 24½" x 21" x 30" |
| Coil Ship Weight | 78 lbs |
| Communication Protocol | Communicating (ComfortNet / ComfortBridge compatible) |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Refrigerant GWP | 675 (vs. R-410A at 2,088 — 68% reduction) |
| ASHRAE Safety Classification | A2L (Lower Flammability, Lower Toxicity) |
| EPA Section 608 | Universal Certification required for refrigerant handling |
| Safety Standards | UL 60335-2-40 compliant; ASHRAE Standard 15 compliant |
| AHRI Certified | Yes (Certificate #218003043) |
| ENERGY STAR® | Cold Climate Certified |
| ETL Listed | Yes |
| Regional Compliance | All U.S. regions; verify local AHJ A2L refrigerant code adoption |
| Federal Tax Credit Eligibility | May qualify under 25C/25D residential energy efficiency tax credits (consult a tax professional for current eligibility requirements) |
| Furnace NOx Emissions | Standard emissions |
Warranty & Registration
Each component in this system carries its own manufacturer warranty. Online registration at www.goodmanmfg.com must be completed within 60 days of the installation date to receive the full registered warranty coverage. Below are the warranty terms per component:
- GZV9SA6010 (Heat Pump Condenser): 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (if compressor fails during first 10 years, Daikin will furnish a new equivalent unit, one time). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Registration is not required in California, Florida, or Québec. Warranty coverage duration may differ in Texas and Florida.
- GCVC961205DN (Gas Furnace): When registered within 60 days: Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. 99-Year Heat Exchanger Limited Warranty may apply per model. Unregistered: 5-Year Parts Limited Warranty. Registration is not required in California, Florida, or Québec.
- CAPEA6030D3 (Evaporator Coil): When registered within 60 days: 10-Year Parts Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registration is not required in California, Florida, or Québec.
Important: Warranty applies to owner-occupied residences. Different warranty terms apply to non-owner-occupied residences and commercial installations. Warranty does not cover labor, refrigerant, freight, or consequential damages. See official warranty documents for complete terms, limitations, and exclusions.