Pioneer Diamante Essenza 35,000 BTU 17 SEER2 Wall Mounted Single-Zone Mini Split System 208/230V WYT036GLUI17RL

Original price was: $2,699.00.Current price is: $1,848.00.

This is a single-zone ductless mini split heat pump that cools and heats one room or open area without ductwork. At 35,000 BTU/h on a 208/230V circuit, it suits a large great room or open-concept main floor of about 1,000–1,400 sq ft in a home without ductwork or where central air falls short. 35,000 BTU/h cooling / 35,400 BTU/h heating (rated) 17.0 SEER2 / 8.5 HSPF2 (Region IV) 208/230V, 35A double-pole breaker 16 ft installation kit included; professional installation required

Fast Shipping

Free Shipping · Dispatches in 1–2 Business Days (Arrives in 3–7 Days)

Freight Delivery

Free Curbside Liftgate Service + 100% Transit Damage Insurance

Dealer Guarantee

Authorized Dealer · Full Factory Warranty · 30-Day Easy Returns

Not sure if this BTU size or voltage fits your space? Call 1-562-709-6010 or Chat Live 24/7 — we will verify your sizing free. Request a Free Sizing Check

SKU: WYT036GLUI17RL
Category:
Brands:

This is a single-zone ductless mini split heat pump that cools and heats one room or open area without ductwork. At 35,000 BTU/h on a 208/230V circuit, it suits a large great room or open-concept main floor of about 1,000–1,400 sq ft in a home without ductwork or where central air falls short.

The Pioneer Diamante Essenza WYT036GLUI17RL pairs the WT036GLUI17HLD high-wall indoor unit with the YN036GLUI17RPD inverter outdoor unit as an AHRI-certified matched system (AHRI Ref. No. 217048738), rated at 17.0 SEER2 and 8.5 HSPF2 (Region IV). Because the indoor unit mounts high on a wall inside the room, there is no ceiling framing, joist-bay fitment, or ductwork to plan around, only a wall penetration for the line set. The variable-speed inverter compressor modulates from 7,500 to 36,000 BTU/h in cooling, so it runs longer at lower output instead of cycling on and off, which keeps room temperature steadier and the indoor unit as quiet as 39 dB(A) on its lowest setting.

System Components

  • Outdoor condenser (YN036GLUI17RPD): inverter-driven rotary compressor, factory pre-charged with R-32 refrigerant for line runs up to 25 ft; 63 dB(A) rated sound level.
  • Wall-mounted indoor unit (WT036GLUI17HLD): high-wall air handler with motorized up-down and left-right louvers, washable return-air filters, and dual drain options; 55/52/46/41/39 dB(A) (Turbo/High/Med/Low/Mute).
  • 16 ft installation kit: 16 ft insulated copper line set, 16 ft four-wire communication cable, and 10 ft drain hose.
  • Handheld wireless remote controller with cooling, heating, dry, and fan modes plus timer.
  • Installation accessories: indoor unit mounting plate and screws, wall sleeve, wall-hole sealant, wrapping tape, and an Allen wrench for opening the service valves.

Installation Requirements & Accessories

  • Electrical: dedicated 208–230V single-phase circuit, 35A double-pole breaker (MCA 23A). Pioneer notes tandem-type breakers will not work.
  • Communication cable: AWG #16 x 4-core TC-ER cable between indoor and outdoor units (16 ft included).
  • Refrigerant piping: 1/4 in. liquid and 5/8 in. suction flare connections. The included 16 ft line set covers installations with up to 16 ft of piping between the indoor and outdoor units.
  • Longer runs: factory charge covers 25 ft; add 0.11 oz of R-32 per foot beyond that, up to 100 ft total length and 65 ft height difference. Longer line sets are sold separately.
  • Room area: minimum 63 sq ft room area at a 6 ft mounting height (A2L refrigerant requirement).
  • Professional installation required: flare connections, nitrogen pressure test, evacuation, and leak check.
  • Not Compatible With: 115V/120V circuits.
  • Not Compatible With: Tandem-type breakers (a double-pole breaker is required).
  • Not Compatible With: Multiple indoor units — this outdoor unit supports one indoor head only (single-zone).
  • Not Compatible With: Indoor or outdoor units other than its AHRI-matched pair (WT036GLUI17HLD / YN036GLUI17RPD), including other Pioneer series.
  • Not Included: Line set longer than 16 ft (runs over 25 ft also require added refrigerant).
  • Not Included: Outdoor unit mounting bracket or pad, electrical disconnect, breaker, and power supply wiring.

Pro-Installer Tip

Pioneer’s installation manual notes that its line sets arrive pre-flared, but a flare face dented in transit is a common source of slow leaks on a new install. Inspect both flares before connecting, re-cut and re-flare any damaged end with an eccentric flaring tool, and tighten the 1/4 in. liquid flare and the 5/8 in. suction flare to the values in the installation manual’s torque table using a digital torque wrench with a backup wrench on the valve body. On this size the 5/8 in. flare nut needs substantially more torque than the liquid side, which is exactly where under-tightening by feel happens.

A correctly torqued flare holds the factory R-32 charge for the life of the system; an under-torqued flare bleeds charge until the inverter compressor runs starved, capacity drops, and protective error codes appear. After pressure-testing with dry nitrogen, evacuate the circuit to 500 microns or lower and confirm the reading holds on a digital micron gauge before opening the service valves (Pioneer’s WYT-17 manual calls for a triple evacuation with a 4-hour hold). For runs beyond 25 ft, weigh in 0.11 oz of R-32 per extra foot; skipping the adjustment on a long run to the 100 ft limit leaves the system undercharged from day one.

R-32 is an A2L (mildly flammable) refrigerant. Opening the circuit, recovering refrigerant, or adding charge must be done by an EPA Section 608-certified technician using leak detectors and recovery equipment rated for A2L refrigerants, and a leak-free, properly evacuated system is also what lets it deliver its rated 17.0 SEER2 efficiency.

Key Benefits

  • Variable-speed comfort: the inverter compressor modulates from 7,500 to 36,000 BTU/h in cooling to match the load instead of cycling at full power.
  • Quiet operation: indoor sound level as low as 39 dB(A) on Mute; outdoor unit rated at 63 dB(A).
  • Heating to 5°F: heating operation rated down to 5°F outdoors, with a maximum output of 18,000 BTU/h at 5°F.
  • Dehumidification: dedicated dry mode removes up to 150 pints of moisture per day.
  • Easy-maintenance air filtration: washable, reusable return-air filters behind a flip-open front panel.
  • Even air distribution: motorized up-down and left-right louvers, plus auto-restart with memory after a power outage.

Technical Specifications

Spec Value Unit
Brand Pioneer
Series Diamante Essenza (WYT-17)
System Model (Full Set) WYT036GLUI17RL
Indoor Unit Model WT036GLUI17HLD
Outdoor Unit Model YN036GLUI17RPD
AHRI Certified Reference Number 217048738
Indoor Unit Architecture Wall Mounted (High-Wall)
System Type Single-Zone Mini Split Heat Pump System
Zone Count 1 zone
DIY Status No — Professional Installation Required
Cooling Capacity (Rated, 95°F) 35,000 BTU/h
Cooling Capacity Range 7,500–36,000 BTU/h
Heating Capacity (Rated, 47°F) 35,400 BTU/h
Heating Capacity Range 7,500–36,000 BTU/h
Heating Capacity (Rated, 17°F) 20,400 BTU/h
Maximum Heating Capacity at 5°F 18,000 BTU/h
SEER2 17.0 BTU/W·h
EER2 9.5 BTU/W·h
HSPF2 (Region IV) 8.5 BTU/W·h
HSPF2 (Region V) 7.5 BTU/W·h
COP2 at 47°F 3.2 W/W
COP2 at 5°F 1.8 W/W
Cooling Operating Range (Outdoor Ambient) 54°F to 122°F °F
Heating Operating Range (Outdoor Ambient) 5°F to 86°F °F
Thermostat Setting Range 62°F to 86°F °F
Voltage (Nominal) 208/230 V
Power Supply Range 208–230 V
Phase 1 (Single-Phase)
Frequency 60 Hz
Breaker Size (Maximum) 35 A
Breaker Type Double-Pole (tandem breakers not compatible)
Minimum Circuit Ampacity (MCA) 23 A
Rated Current (Cooling / Heating) 14.6 / 13.2 A
Rated Power Input (Cooling / Heating) 3,350 / 3,000 W
Refrigerant R-32 (A2L)
Factory Refrigerant Charge 56.1 oz
Line Length Covered by Factory Charge 25 ft
Additional Charge Beyond 25 ft 0.11 oz/ft
Liquid Line Size (OD) 1/4 in
Suction (Gas) Line Size (OD) 5/8 in
Included Line Set Length 16 ft
Maximum Line Length 100 ft
Maximum Height Difference 65 ft
Indoor/Outdoor Communication Cable AWG #16 x 4-Core (TC-ER)
Indoor Sound Level (Turbo/High/Med/Low/Mute) 55/52/46/41/39 dB(A)
Indoor Sound Level (Mute) 39 dB(A)
Outdoor Sound Level 63 dB(A)
Indoor Airflow (Turbo/High/Med/Low/Mute) 882/741/564/458/411 CFM
Moisture Removal 150 pints/day
Recommended Room Size 1,000–1,400 sq ft
Minimum Room Area (A2L, 6 ft mounting height) 63 sq ft
Indoor Unit Dimensions (W x D x H) 46-7/8 x 10-1/4 x 14-1/4 in
Indoor Unit Net Weight 38.6 lb
Outdoor Unit Dimensions (W x D x H) 38-1/2 x 16-1/2 x 31-5/8 in
Outdoor Unit Net Weight 105.8 lb
Compressor Inverter-Driven Rotary (Variable Speed)
Certifications AHRI / ETL / ISO certified combination
Warranty Up to 5-year parts and compressor (registered); 1-year (unregistered)

Compatibility & Fitment

  • Matched System: AHRI-certified match: WT036GLUI17HLD indoor unit with YN036GLUI17RPD outdoor unit (AHRI Ref. 217048738).
  • Electrical Compatibility: Compatible with a dedicated 208–230V single-phase circuit on a 35A double-pole breaker.
  • Line Set Compatibility: 1/4 in. liquid x 5/8 in. suction flare line set; runs up to 100 ft with up to 65 ft height difference.
  • Mounting: Indoor unit mounts high on a wall inside the conditioned room; no ceiling framing, joist bay, or ductwork required.
  • Not Compatible With: 115V/120V circuits.
  • Not Compatible With: Tandem-type breakers (a double-pole breaker is required).
  • Not Compatible With: Multiple indoor units — this outdoor unit supports one indoor head only (single-zone).
  • Not Compatible With: Indoor or outdoor units other than its AHRI-matched pair (WT036GLUI17HLD / YN036GLUI17RPD), including other Pioneer series.
  • Not a DIY System: Not a pre-charged quick-connect / no-vacuum kit; requires flare connections, evacuation, and leak testing.
  • Not Included: Line set longer than 16 ft (runs over 25 ft also require added refrigerant).
  • Not Included: Outdoor unit mounting bracket or pad, electrical disconnect, breaker, and power supply wiring.
  • Not Rated For: Heating below 5°F outdoor ambient.
  • Not Rated For: Cooling below 54°F outdoor ambient.

Frequently Asked Questions

What breaker size do I need for this system?

Pioneer specifies a 35A double-pole breaker on a dedicated 208–230V single-phase circuit (minimum circuit ampacity 23A). Pioneer’s installation manual notes that tandem-type breakers will not work. Final wire gauge and disconnect requirements should be confirmed by a licensed electrician to NEC and local code.

Is professional installation required to keep the warranty valid, or is this a true DIY kit?

This is not a DIY or no-vacuum kit. The refrigerant connections are flare fittings that must be torqued, evacuated, and leak-tested. Pioneer’s 5-year Standard Warranty requires installation within 90 days of shipment and warranty registration, and the registration card asks for the installer’s license number and recorded system pressures. Systems that are not registered are covered only by the 1-year Basic Warranty.

Is the line set included, and what if I need a longer run?

Yes. A 16 ft insulated copper line set (1/4 in. liquid x 5/8 in. suction), a 16 ft communication cable, and a 10 ft drain hose are included. The factory charge covers line runs up to 25 ft; beyond that, add 0.11 oz of R-32 per additional foot. The maximum line length is 100 ft with a maximum 65 ft height difference. Line sets longer than 16 ft are sold separately.

Does this system work in cold climates (low-ambient heating)?

Heating operation is rated down to 5°F outdoors, where Pioneer lists a maximum output of 18,000 BTU/h (COP2 1.8), compared with 35,400 BTU/h at 47°F. It is not rated for heating below 5°F, so it is better suited to moderate climates or to supplemental heating in colder regions.

What size room is this system designed for?

Pioneer recommends this system for spaces of about 1,000–1,400 sq ft. Because it uses A2L (R-32) refrigerant, the room must also meet a minimum area of 63 sq ft at a 6 ft mounting height. Insulation, sun exposure, ceiling height, and climate all affect sizing, so a load calculation is recommended.

Compliance & Warranty

  • Installation by a licensed HVAC professional is required to maintain warranty. Pioneer’s warranty registration card must be completed with the installer’s license number and recorded system operating pressures.
  • Standard Warranty (registered): up to 5 years on the compressor and 5 years on other parts. The system must be installed within 90 days of shipment and registered with Pioneer (online at pdhvac.com or by the mailed registration card) promptly after installation.
  • Basic Warranty (unregistered): 1 year parts and compressor.
  • Coverage terms: parts only. Labor, refrigerant, and refrigerant-related service are not covered. Warranty is limited to the original owner at the original installation address in the United States and excludes damage from faulty installation or misapplication.
  • Refrigerant compliance: R-32 is an A2L refrigerant. Refrigerant handling requires EPA Section 608 certification, and the installation must meet the minimum room-area requirements in the manufacturer’s installation manual.
  • Certification: AHRI / ETL / ISO certified indoor and outdoor combination.
Brand

Pioneer

Series

Diamante Essenza (WYT-17)

Cooling Capacity

35,000 BTU/h

Heating Capacity

35,400 BTU/h

SEER2

17.0

HSPF2 (Region IV)

8.5

Voltage

208/230V

Breaker Size

35A

Zone Count

1

Indoor Unit Type

Wall Mounted (High-Wall)

Installation

No — Professional Installation Required

Refrigerant

R-32 (A2L)

Included Line Set Length

16 ft

Indoor Sound Level (Mute)

39 dB(A)

There are no reviews yet.

Be the first to review “Pioneer Diamante Essenza 35,000 BTU 17 SEER2 Wall Mounted Single-Zone Mini Split System 208/230V WYT036GLUI17RL”

Your email address will not be published. Required fields are marked *

Shipped Factory-Direct. Backed by Real HVAC Support.

Every system ships brand-new in sealed factory packaging with full manufacturer warranty coverage and free contiguous US shipping. Need installation accessories, line sets, or contractor trade pricing?

ASK AN HVAC EXPERT