This single-zone ductless heat pump cools and heats one room or open area without ductwork and keeps heating in outdoor temperatures as low as -13°F. At 18,000 BTU/h on a 208/230V circuit, it suits an open living room, primary suite, or small apartment or ADU of about 500–750 sq ft in colder climates.
Overview
The Pioneer Quantum Ultra WYT018GLSI24RL pairs the WT018GLSI24HLG high-wall indoor unit with the YN018GLSI24RPG inverter outdoor unit as an AHRI-certified matched system (AHRI Ref. No. 217048752), rated at 23.0 SEER2 and 10.0 HSPF2 (Region IV). Pioneer’s submittal sheet lists this combination as ENERGY STAR certified, and the series brochure shows it on the NEEP list. Because the indoor unit mounts high on a wall inside the room, there is no ceiling framing or ductwork to plan around, only a wall penetration for the line set. The variable-speed inverter compressor modulates from 4,000 to 19,000 BTU/h in cooling, so it runs longer at lower output instead of cycling on and off, which keeps room temperature steadier and the indoor unit as quiet as 34 dB(A) on Mute.
System Components
- Outdoor condenser (YN018GLSI24RPG): inverter-driven rotary compressor, factory-charged with 45.5 oz of R-454B for line runs up to 25 ft; 53 dB(A) rated sound level.
- Wall-mounted indoor unit (WT018GLSI24HLG): high-wall air handler with motorized up-down and left-right louvers, washable return-air filters, dual drain options, and built-in refrigerant leak sensing; 50/47/43/38/34 dB(A) (Turbo/High/Med/Low/Mute).
- Installation kit (your choice at checkout): Pioneer copper piping kit in 10, 16, 25, 33, or 50 ft (pre-flared insulated copper line set, matching-length 4-lead communication wire, 10 ft condensate drain hose, wall sleeve with cap and putty, and non-adhesive wrapping tape); Pioneer EZFlex full installation kit in 10, 16, or 25 ft (flexible insulated stainless-steel line set, 4-lead communication wire with pre-crimped spade terminals, wall sleeve and cap, two packs of wall-sealing putty, reinforced drain hose, non-adhesive wrapping tape, and a packet of Pioneer Leak Guard); or no kit if your installer supplies the line set.
- Wi-Fi module: included for app control; requires a 2.4 GHz Wi-Fi network.
- Wireless remote controller with holder and batteries; cooling, heating, dry, and fan modes, timer, and I Feel mode.
- Installation accessories: indoor mounting plate (pre-attached) and screws, outdoor drain joint plug, and an Allen wrench for opening the service valves.
Installation Requirements & Accessories
- Electrical: dedicated 208–230V single-phase circuit, 20A double-pole breaker (MCA 12A). Pioneer notes tandem-type breakers will not work.
- Communication cable: AWG #16 x 4-core TC-ER cable between indoor and outdoor units. Pioneer’s copper and EZFlex kits include a matching 4-lead communication wire; with the No Kit option, your installer supplies the cable, drain hose, wall sleeve, sealant, and wrapping tape.
- Refrigerant piping: 1/4 in. liquid and 1/2 in. suction flare connections, using the installation kit selected at checkout or a line set supplied by your installer. EZFlex kits cannot be cut or shortened.
- Longer runs: factory charge covers 25 ft; add 0.11 oz of R-454B per foot beyond that, up to 65 ft total length and 50 ft height difference.
- Room area: minimum 51 sq ft floor area with the indoor unit at least 6 ft above the floor (A2L refrigerant requirement); lower mounting heights require a larger room. Some installations also require Pioneer’s auxiliary external leak sensor.
- Professional installation required: flare connections, nitrogen pressure test, evacuation, and leak check.
- Not Compatible With: 115V/120V circuits.
- Not Compatible With: Tandem-type breakers (a double-pole breaker is required).
- Not Compatible With: Multiple indoor units — this outdoor unit supports one indoor head only (single-zone).
- Not Compatible With: Indoor or outdoor units other than its AHRI-matched pair (WT018GLSI24HLG / YN018GLSI24RPG), including other Pioneer series.
- Not Included: Line set, unless an installation kit option is selected (runs over 25 ft require added refrigerant).
- Not Included: Outdoor unit mounting bracket or pad, electrical disconnect, breaker, and power supply wiring.
Pro-Installer Tip
If you choose a 33 or 50 ft copper kit for this size, the long 1/2 in. suction line is where kinks and dented flares show up. Form bends with a lineset bending tool, inspect each factory flare before connecting, re-flare any damaged face with an eccentric flaring tool, and torque both flare nuts to the installation manual’s table using a digital torque wrench with a backup wrench on the valve body. The larger suction flare needs substantially more torque than the 1/4 in. liquid side, which is exactly where under-tightening by feel happens.
A correctly torqued flare holds the factory R-454B charge for the life of the system; an under-torqued flare bleeds charge until capacity drops and protective error codes appear. Pioneer’s installation manual calls for a triple evacuation: pull down to 8,000 microns and break with dry nitrogen, pull to 5,000 microns and break again, then pull to 500 microns and confirm on a digital micron gauge that the vacuum holds for at least 4 hours before opening the service valves. On runs beyond 25 ft, weigh in 0.11 oz of R-454B per extra foot; skipping the adjustment leaves the system undercharged from day one.
R-454B is an A2L (mildly flammable) refrigerant. Opening the circuit, recovering refrigerant, or adding charge must be done by an EPA Section 608-certified technician using leak detectors and recovery equipment rated for A2L refrigerants, and a leak-free, properly evacuated system is also what lets it deliver its rated 23.0 SEER2 efficiency.
Key Benefits
- Variable-speed comfort: the inverter compressor modulates from 4,000 to 19,000 BTU/h in cooling to match the load instead of cycling at full power.
- Quiet operation: indoor sound level as low as 34 dB(A) on Mute; outdoor unit rated at 53 dB(A).
- Heating to -13°F: maximum heating output of 11,000 BTU/h at -4°F and 9,200 BTU/h at -13°F; cooling works in outdoor temperatures up to 131°F.
- Built-in Wi-Fi: included Wi-Fi module for smartphone app control and scheduling on a 2.4 GHz network.
- Dehumidification: dedicated dry mode removes up to 110 pints of moisture per day.
- Comfort where you sit: I Feel mode reads the temperature at the remote; motorized up-down and left-right louvers spread airflow, and auto-restart with memory resumes after a power outage.
Technical Specifications
| Spec | Value | Unit |
|---|---|---|
| Brand | Pioneer | |
| Series | Quantum Ultra (WYT-24) | |
| System Model (Full Set) | WYT018GLSI24RL | |
| Indoor Unit Model | WT018GLSI24HLG | |
| Outdoor Unit Model | YN018GLSI24RPG | |
| AHRI Certified Reference Number | 217048752 | |
| Indoor Unit Architecture | Wall Mounted (High-Wall) | |
| System Type | Single-Zone Mini Split Heat Pump System | |
| Zone Count | 1 | zone |
| DIY Status | No — Professional Installation Required | |
| Cooling Capacity (Rated, 95°F) | 18,000 | BTU/h |
| Cooling Capacity Range | 4,000–19,000 | BTU/h |
| Heating Capacity (Rated, 47°F) | 19,000 | BTU/h |
| Heating Capacity Range | 4,000–21,000 | BTU/h |
| Heating Capacity (Rated, 17°F) | 15,000 | BTU/h |
| Maximum Heating Capacity at 5°F | 13,600 | BTU/h |
| Maximum Heating Capacity at -4°F | 11,000 | BTU/h |
| Maximum Heating Capacity at -13°F | 9,200 | BTU/h |
| SEER2 | 23.0 | BTU/W·h |
| EER2 | 12.5 | BTU/W·h |
| HSPF2 (Region IV) | 10.0 | BTU/W·h |
| HSPF2 (Region V) | 8.2 | BTU/W·h |
| COP2 at 47°F | 3.64 | W/W |
| COP2 at 5°F | 1.8 | W/W |
| Cooling Operating Range (Outdoor Ambient) | 5°F to 131°F | °F |
| Heating Operating Range (Outdoor Ambient) | -13°F to 86°F | °F |
| Thermostat Setting Range | 62°F to 86°F | °F |
| Voltage (Nominal) | 208/230 | V |
| Power Supply Range | 208–230 | V |
| Phase | 1 (Single-Phase) | |
| Frequency | 60 | Hz |
| Breaker Size (Maximum) | 20 | A |
| Breaker Type | Double-Pole (tandem breakers not compatible) | |
| Minimum Circuit Ampacity (MCA) | 12 | A |
| Rated Current (Cooling / Heating) | 6.2 / 6.1 | A |
| Rated Power Input (Cooling / Heating) | 1,390 / 1,360 | W |
| Refrigerant | R-454B (A2L) | |
| Factory Refrigerant Charge | 45.5 | oz |
| Line Length Covered by Factory Charge | 25 | ft |
| Additional Charge Beyond 25 ft | 0.11 | oz/ft |
| Liquid Line Size (OD) | 1/4 | in |
| Suction (Gas) Line Size (OD) | 1/2 | in |
| Included Line Set Length | None — installation kit selected at purchase | |
| Installation Kit Options | Standard copper line set kit (10 / 16 / 25 / 33 / 50 ft), EZFlex flexible line set kit (10 / 16 / 25 ft), or no kit | |
| Maximum Line Length | 65 | ft |
| Maximum Height Difference | 50 | ft |
| Indoor/Outdoor Communication Cable | AWG #16 x 4-Core (TC-ER) | |
| Indoor Sound Level (Turbo/High/Med/Low/Mute) | 50/47/43/38/34 | dB(A) |
| Indoor Sound Level (Mute) | 34 | dB(A) |
| Outdoor Sound Level | 53 | dB(A) |
| Indoor Airflow (Turbo/High/Med/Low/Mute) | 735/676/529/423/394 | CFM |
| Moisture Removal | 110 | pints/day |
| Recommended Room Size | 500–750 | sq ft |
| Minimum Room Area (A2L, 6 ft mounting height) | 51 | sq ft |
| Refrigerant Leak Detection | Built-in leak sensing in indoor unit | |
| Wi-Fi / App Control | Wi-Fi module included (requires 2.4 GHz Wi-Fi network) | |
| Indoor Unit Dimensions (W x D x H) | 43-1/8 x 8-3/4 x 13 | in |
| Indoor Unit Net Weight | 30.9 | lb |
| Outdoor Unit Dimensions (W x D x H) | 36-1/2 x 15 x 27-1/2 | in |
| Outdoor Unit Net Weight | 90.4 | lb |
| Compressor | Inverter-Driven Rotary (Variable Speed) | |
| Certifications | AHRI / ETL / ISO certified combination | |
| ENERGY STAR (per manufacturer documents) | Yes | |
| NEEP Listing (per manufacturer brochure) | Yes | |
| Warranty | Up to 10-year compressor / 7-year parts (installed within 90 days by a registered technician and registered); 5-year parts and compressor (other registered installations); 1-year (unregistered) |
Compatibility & Fitment
- Matched System: AHRI-certified match: WT018GLSI24HLG indoor unit with YN018GLSI24RPG outdoor unit (AHRI Ref. 217048752).
- Electrical Compatibility: Compatible with a dedicated 208–230V single-phase circuit on a 20A double-pole breaker.
- Line Set Compatibility: 1/4 in. liquid x 1/2 in. suction flare line set; runs up to 65 ft with up to 50 ft height difference.
- Mounting: Indoor unit mounts high on a wall inside the conditioned room; no ceiling framing, joist bay, or ductwork required.
- Smart Control: Wi-Fi module included for smartphone app control on a 2.4 GHz Wi-Fi network.
- Not Compatible With: 115V/120V circuits.
- Not Compatible With: Tandem-type breakers (a double-pole breaker is required).
- Not Compatible With: Multiple indoor units — this outdoor unit supports one indoor head only (single-zone).
- Not Compatible With: Indoor or outdoor units other than its AHRI-matched pair (WT018GLSI24HLG / YN018GLSI24RPG), including other Pioneer series.
- Not a DIY System: Not a pre-charged quick-connect / no-vacuum kit; requires flare connections, evacuation, and leak testing.
- Not Included: Line set, unless an installation kit option is selected (runs over 25 ft require added refrigerant).
- Not Included: Outdoor unit mounting bracket or pad, electrical disconnect, breaker, and power supply wiring.
- Not Rated For: Heating below -13°F or cooling below 5°F outdoor ambient.
Frequently Asked Questions
What size breaker and circuit do I need?
Pioneer specifies a 20A double-pole breaker on a dedicated 208–230V single-phase circuit, with a minimum circuit ampacity of 12A. Pioneer’s installation manual notes that tandem-type breakers will not work. Final wire gauge and disconnect requirements should be confirmed by a licensed electrician to NEC and local code.
Can I install this myself, or does it need a professional to keep the warranty?
It needs a licensed professional. It uses flare refrigerant connections that must be torqued, pressure-tested, evacuated, and leak-checked, so it is not a DIY or no-vacuum system. Pioneer’s longest coverage, up to 10 years on the compressor and 7 years on other parts, applies when the system is installed within 90 days by a registered technician and registered. Other registered installations default to 5 years parts and compressor, and unregistered systems receive the 1-year Basic Warranty.
Does it come with a line set?
Not in the box. Choose an installation kit when ordering: a standard copper line set kit in 10, 16, 25, 33, or 50 ft, an EZFlex flexible line set kit in 10, 16, or 25 ft, or no kit if your installer is supplying a 1/4 in. x 1/2 in. flare line set. Both kits also include a 4-lead communication wire, drain hose, wall sleeve, sealing putty, and wrapping tape. Pioneer notes EZFlex line sets cannot be cut or shortened, so pick a length that covers the full run. The factory charge covers up to 25 ft; longer runs need 0.11 oz of R-454B per additional foot, up to 65 ft total.
Will it keep heating in a cold climate?
Yes. Pioneer rates heating operation down to -13°F outdoors. Maximum heating output is 13,600 BTU/h at 5°F, 11,000 BTU/h at -4°F, and 9,200 BTU/h at -13°F, compared with 19,000 BTU/h rated at 47°F, so plan backup heat if your design temperature is near the bottom of that range.
How big a room will it handle?
Pioneer recommends this system for spaces of about 500–750 sq ft. Because it uses A2L (R-454B) refrigerant, the room must also have at least 51 sq ft of floor area with the indoor unit mounted at least 6 ft high; lower mounting heights require a larger room. Insulation, sun exposure, ceiling height, and climate all affect sizing, so a load calculation is recommended.
Compliance & Warranty
- Installation by a licensed HVAC professional is required to maintain warranty. Pioneer’s warranty registration form asks for the installer’s license number and recorded system operating pressures.
- Extended coverage: up to 10 years on the compressor and 7 years on other internal parts when the system is installed within 90 days by a registered technician and registered with Pioneer.
- Standard Warranty: other registered installations default to 5 years parts and compressor. Register online at pdhvac.com or with the registration form promptly after installation.
- Basic Warranty (unregistered): 1 year parts and compressor.
- Coverage terms: parts only. Labor, refrigerant, and refrigerant-related service are not covered. Warranty is limited to the original owner at the original installation address in the United States, is not transferable, and excludes damage from faulty installation or misapplication.
- Refrigerant compliance: R-454B is an A2L refrigerant. Refrigerant handling requires EPA Section 608 certification, and the installation must meet the minimum room-area requirements in the installation manual.
- Certification: AHRI / ETL / ISO certified indoor and outdoor combination.











Reviews
There are no reviews yet.