This is a single-zone ductless mini split air conditioner and heat pump system for cooling and heating one larger room, open living area, or addition without ductwork. It's built for homeowners who need a higher-capacity 36,000 BTU system on a dedicated 208-230V circuit.
The Eclipse Series pairs an outdoor condenser with a wall-mounted indoor head, matched and AHRI-certified as a single-zone system. This configuration is well suited to a bonus room, garage, or living space where a wall-mount unit is the appropriate delivery method for the space and BTU load. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
System Components
- Outdoor condenser unit: Model ASPCI4H4S36R (36,000 BTU, 208-230V)
- Indoor unit: Model ASPEM4HS36R, wall-mounted architecture
Installation Requirements & Accessories
- Voltage: 208-230V — not compatible with 115V-only circuits
- Line set: sold separately; size not specified in manufacturer data provided ([NEEDS VERIFICATION])
- Professional installation required — this is not a pre-charged DIY kit
- Not included: line set, mounting bracket/wall sleeve, breaker/disconnect, refrigerant beyond factory charge in the outdoor unit
- Not a listed match for other Eclipse Series capacities (e.g., 30,000 BTU ASPCI4H4S30 / ASPEM4HS30) — indoor and outdoor units must be paired by matching model number as listed
Pro-Installer Tip
On a 36,000 BTU system, flare connections at the outdoor service valves see higher torque requirements than smaller residential systems — an under-torqued flare here is a common source of slow refrigerant leaks and nuisance "low charge" callbacks. Use a digital torque wrench set to the fitting manufacturer's spec rather than "feel," and always pull the system down below 500 microns with a calibrated micron gauge before opening the service valves — a rushed vacuum is the single biggest cause of moisture-related compressor failure and repeat service calls on larger-tonnage systems. This work must be performed by an EPA Section 608-certified technician handling refrigerant.
Key Benefits
- 36,000 BTU capacity suited to larger rooms or open floor plans
- 16 SEER rated efficiency
- 208-230V dedicated circuit design
- AHRI-certified matched indoor/outdoor pairing
- Wall-mounted indoor head for straightforward placement in most rooms
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 36000 | BTU/h |
| SEER | 16 | — |
| Voltage | 208-230 | V |
| Zone Count | 1 | zone |
| Outdoor Unit Model | ASPCI4H4S36R | — |
| Indoor Unit Model | ASPEM4HS36R | — |
| Indoor Unit Architecture | Wall Mounted | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- The outdoor condenser (ASPCI4H4S36R) is designed to be matched with the indoor wall-mounted head (ASPEM4HS36R) as an AHRI-certified pair.
- Compatible with dedicated 208-230V single-phase circuits.
- Not compatible with 115V-only circuits.
- Not a listed match for other Eclipse Series capacity pairs, such as the 30,000 BTU ASPCI4H4S30 / ASPEM4HS30 combination.
- Line set is not included — purchase separately based on the installation manual's specified sizing.
- Wall mounting bracket and any wall sleeve are not included.
FAQ
What breaker size do I need for this system?
[NEEDS VERIFICATION] — the manufacturer data provided does not list a breaker size for this system. Confirm the required breaker/circuit ampacity against the outdoor unit nameplate or installation manual before wiring.
Is professional installation required to keep the warranty valid, or is this a true DIY kit?
This is not a DIY pre-charged system. It requires professional installation, including refrigerant line brazing/flaring, evacuation, and charging by a licensed HVAC technician, to maintain the manufacturer warranty.
Is the line set included, and if not, what size do I need to buy?
The line set is not included with this system. Line set size is [NEEDS VERIFICATION] — the manufacturer specs provided do not list a required line set diameter for this model. Confirm sizing with the installation manual before purchasing.
Does this system work in cold climates (low-ambient heating)?
[NEEDS VERIFICATION] — the manufacturer data provided does not include a published low-ambient heating operating range for this model.
Compliance & Warranty
Installation by a licensed HVAC professional is required to maintain warranty. This system is AHRI-certified as a matched pair per the manufacturer data provided. Refrigerant handling must be performed by an EPA Section 608-certified technician. For full warranty terms, refer to the "Resources (System Manuals and Warranty)" Tab above.