This is a wall-sleeve heat pump for hotel rooms, apartments, or additions where central ductwork isn't available. It heats and cools from one chassis, with electric heat backup for cold-snap days, and it's built for property managers and homeowners who need self-contained, per-room climate control.
Amana PTH123K35AXXX is an R-410A packaged terminal heat pump (PTHP) built for hospitality rooms, multifamily units, and additions where ductwork isn't practical. This is an R-410A K-series chassis (previous-generation, sell-through stock) and is well suited for like-for-like replacement of existing R-410A PTAC/PTHP installations, since R-410A is being phased down under the EPA AIM Act and matching refrigerant type simplifies service. All units meet or exceed ASHRAE 90.1. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Fits the industry-standard 42 in x 16-1/16 in wall sleeve opening.
- Operates on a 230/208V circuit, drawing 19.5A MCA with the 3.5/3.0 kW electric heat installed; requires a 20A breaker (MOP) and NEMA 6-20P/6-20R connection.
- Ships with a factory LCDI power cord (UL 484), standard on all units rated under 250V.
- Wall Sleeve is NOT included - order separately (WS900E, WS900QW, or another sleeve variant matching your project).
- Exterior Architectural Grille is NOT included - order separately (SGK, AGK, or PGK series).
- Not compatible with 115V circuits.
- Not compatible with 265V circuits - do not confuse this with sibling chassis PTH124J, which is the 265V commercial version requiring its own sub-base or hard-wire kit.
- Not a drop-in fit for non-standard or custom-depth sleeve openings; use the extra-deep sleeve series if your wall depth exceeds standard dimensions.
The technical friction on any PTAC/PTHP retrofit is condensate management - if the sleeve sits level or pitches inward, wash-off from the wet coil backs up into the room instead of draining outside. Pitch the sleeve about 1/4 bubble toward the exterior wall (per the framing note in the manufacturer documentation) and confirm it with a torpedo level before you set trim and grille. This prevents water intrusion into the drywall and insulation over the unit's service life, not just at commissioning. Cross-check the sleeve's rough opening against the framing diagram in the manufacturer's install guide, and log the level check on your commissioning sheet - many property management QA programs require photographic proof of level/pitch before final unit sign-off.
Key Benefits
- Heat pump operation delivers 10,600/10,500 BTU/h of heating from the compressor at 230V/208V before the electric heat strip is even called - lower operating cost than heat-strip-only PTAC units in moderate climates.
- 3.5/3.0 kW electric heat backup (12,000 BTU/h at 230V, 9,900 BTU/h at 208V) covers cold-snap capacity when the heat pump alone can't keep up.
- 1.7 pints/hr of dehumidification at rated conditions helps manage humidity in guest rooms and multifamily units without a separate dehumidifier.
- Fresh air vent adjustable from 65-95 CFM for make-up air in occupied spaces.
- EER of 11.0/11.1 and COP of 3.2/3.2 for straightforward efficiency comparison against other PTHP chassis.
- R-410A refrigerant matches most existing PTAC/PTHP stock for straightforward like-for-like replacements.
| Spec | Value | Unit |
|---|---|---|
| System Type | PTHP (Packaged Terminal Heat Pump) with Electric Heat Backup | - |
| Refrigerant | R-410A | - |
| Voltage | 230/208 | V |
| Cooling Capacity (230V/208V) | 11,600/11,400 | BTU/h |
| Compressor Cooling Amps | 6.1 | A |
| Compressor Cooling Watts | 1,050/1,025 | W |
| EER | 11.0/11.1 | - |
| Heat Pump Heating Capacity (230V/208V) | 10,600/10,500 | BTU/h |
| Compressor Heating Amps | 6.1 | A |
| Compressor Heating Watts | 970/960 | W |
| COP | 3.2/3.2 | - |
| Electric Heat Strip Size | 3.5/3.0 | kW |
| Electric Heat Stages | 1 | - |
| Electric Heat Backup Capacity (230V) | 12,000 | BTU/h |
| Electric Heat Backup Capacity (208V) | 9,900 | BTU/h |
| Total Heat Watts (230V/208V) | 3,570/2,935 | W |
| Total Heat Amps (230V/208V) | 15.5/14.1 | A |
| MCA | 19.5 | A |
| MOP (Max Overcurrent Protection) | 20 | A |
| Power Cord / NEMA Plug Type | 6-20P | - |
| LCDI Cord Compliance | Factory LCDI power cord, UL 484 (applies to all units under 250V) | - |
| High/Low CFM (Wet Coil) | 330/245 | CFM |
| High/Low CFM (Dry Coil) | 303/283 | CFM |
| Fresh Air Vent CFM | 65-95 | CFM |
| Dehumidification | 1.7 | pints/hr |
| Net Weight | 108 | lb |
| Shipping Weight | 125 | lb |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included - sold separately | - |
| Exterior Architectural Grille Included | Not Included - sold separately | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via NEMA 6-20P/6-20R power cord and receptacle.
- Fits standard 42 in x 16-1/16 in wall sleeve openings (e.g., WS900E, WS900QW sleeve family).
- Not compatible with 115V circuits.
- Not compatible with 265V circuits - the 265V commercial version of this chassis is PTH124J, which requires its own Amana sub-base (PTSB4**E) or hard-wire kit (PTPWHWK4 with disconnect PSHW04A), sold separately. Do not attempt to run this 230/208V unit, PTH123K35AXXX, on a 265V circuit.
- Wall Sleeve NOT included with this unit - order separately.
- Exterior Architectural Grille NOT included with this unit - order separately.
- Not a drop-in replacement for non-standard or custom-depth sleeve openings; use the extra-deep sleeve series (16-24 in in 1-in increments, plus 28/30/32/36/40 in options) if your wall cavity is deeper than standard.
| Spec | Value |
|---|---|
| Refrigerant Type | R-410A |
| Refrigerant Phase-Down Note | R-410A is subject to phase-down under the EPA AIM Act; this unit suits like-for-like replacement of existing R-410A PTAC/PTHP installations |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Electrical Compliance (Power Cord) | Factory LCDI power cord per UL 484 (units under 250V) |
| Electrical Compliance (Overcurrent Protection) | 20A MOP; dedicated 20A circuit required with electric heat installed |
| Voltage Operating Range | 197V minimum to 253V maximum for 230/208V models |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This chassis fits the industry-standard 42 in x 16-1/16 in sleeve opening (e.g., WS900E/WS900QW family), but you need to order a sleeve and, if the exterior finish matters, an outdoor grille (SGK, AGK, or PGK) separately.
What breaker size and plug type does this unit require?
With the 3.5/3.0 kW electric heat installed, this unit has an MCA of 19.5A and a maximum overcurrent protection (MOP) rating of 20A, and it ships with a factory NEMA 6-20P power cord. Confirm your receptacle is a matching NEMA 6-20R on a dedicated 20A, 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This model, PTH123K35AXXX, is a 230/208V unit and is not compatible with 265V circuits. The 265V commercial sibling chassis is PTH124J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect switch PSHW04A (sold separately), plus factory-installed cartridge-style time-delay fuses. Do not attempt to wire this unit for 265V service.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] - installer licensing requirements are not specified in the provided source data. Refer to the warranty PDF in the Resources tab for exact installation and registration terms.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in x 16-1/16 in sleeve opening. It is not a drop-in fit for non-standard or custom-depth sleeve openings; those require the extra-deep sleeve variants sold separately.
Warranty & Registration
Amana backs this unit with a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per manufacturer badge documentation. Exact terms, including any distinction between residential and commercial hospitality usage, are set out in the manufacturer warranty PDF - we don't assert coverage details beyond what's confirmed there. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page. If you have questions about your specific installation before you order, ask us - we always reply back.