Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

All things power

RUiXU 48V 5120Wh Server Rack Battery / Schneider Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters) Cut off one end of the T568B standard network cable and reconnect the RJ45 plug according to the following sequence in the diagram. The newly connected RJ45...

Read more

RUiXU 48V 5120Wh Server Rack Battery / Growatt Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters)       Connect Connect the master battery C-up port to the BMS communication port on the inverter.       Battery setting (Inverter Protocol chosen by...

Read more

RUiXU 48V 5120Wh Server Rack Battery / Victron Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters) Cut off one end of the T568B standard network cable and reconnect the RJ45 plug according to the following sequence in the diagram. The newly connected RJ45...

Read more

RUiXU 48V 5120Wh Server Rack Battery / Deye Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters)     Connect Connect the master battery C-up port to the BMS communication port on the inverter. .                 Battery...

Read more

RUiXU 48V 5120Wh Server Rack Battery /Sol-ark Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters)     Connect Connect the master battery C-up port to the BMS communication port on the inverter.       Battery setting (Inverter Protocol chosen by ADD)...

Read more

RUiXU 48V 5120Wh Server Rack Battery / Voltronic or MPP Inverter Communication

By Jonathan Mccrary September 16, 2024 | | 0 comments

Connect Communication Cable Communication Cable Use a standard RJ45/ T568B color code/ CAT5e Ethernet Cable(The maximum length is not more than 10 meters) Cut off one end of the T568B standard network cable and reconnect the RJ45 plug according to the following sequence in the diagram. The newly connected RJ45...

Read more