This is a 600 amp buss bar with 12 mounting positions for 5/16" bolts, used to consolidate multiple battery or inverter cable connections onto a single conductive rail. It's built for installers who need to join several parallel battery cables or terminal lugs at one common point without daisy-chaining ring terminals onto a single stud.
A buss bar like this one is a passive conductor — it has no active components to fail, but its performance depends entirely on clean, torqued mechanical connections. Copper or plated copper buss bars distribute current across multiple parallel cable runs, which reduces the number of ring terminals stacked on a single lug and lowers connection resistance at each junction point. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- 600 amp continuous ampacity rating.
- 12 mounting positions, each sized for a 5/16" bolt.
- Black finish (housing/insulator color as supplied).
- NOT rated to exceed 600A continuous draw — do not oversize downstream breakers or cabling beyond this bar's rating.
- NOT compatible with ring terminals or lugs drilled for bolt sizes other than 5/16" without a hardware adapter.
- Voltage rating [NEEDS VERIFICATION] — not provided in manufacturer data supplied for this listing.
- Solid conductive bar designed to consolidate multiple parallel cable terminations at one point.
- 12 bolt positions reduce the need to stack multiple lugs on a single terminal stud.
- 600A rating supports higher-current parallel battery or inverter cable runs.
- Black finish for the bar housing/insulation.
| Spec | Value | Unit |
|---|---|---|
| Ampacity Rating | 600 | A |
| Bolt Hole Count | 12 | positions |
| Bolt Size | 5/16 | in |
| Color | Black | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
- Fits: applications requiring a 600A-rated buss bar with 12 x 5/16" bolt terminal positions for consolidating battery or inverter cable connections.
- Fits: terminal lugs and ring terminals drilled for 5/16" bolts.
- Does NOT fit: lugs or ring terminals with bolt hole sizes other than 5/16" (e.g., 3/8" or M8/M10 lugs) without a separate adapter.
- Does NOT support continuous current draw above 600A.
- Voltage system compatibility (12V/24V/48V) [NEEDS VERIFICATION] — confirm against your inverter/battery system documentation before purchase.
| Category | Value |
|---|---|
| UL Listing | [NEEDS VERIFICATION] — not provided in supplied manufacturer data |
| NEC Ampacity Reference | 600A continuous rating per manufacturer spec; verify downstream conductor/breaker sizing against NEC ampacity tables |
| IP Rating | [NEEDS VERIFICATION] — not provided in supplied manufacturer data |
FAQ
What amperage is this buss bar rated for?
This buss bar carries a 600 amp rating.
What bolt size does this buss bar use?
It uses 5/16" bolts, with 12 bolt positions on the bar.
Is this buss bar rated for 48V battery systems?
[NEEDS VERIFICATION] Voltage rating is not specified in available manufacturer data. Confirm system voltage compatibility before installation.
Will this buss bar fit any inverter or battery brand's terminal lugs?
It accepts terminal lugs sized for 5/16" bolts. Lugs with a different bolt hole diameter will not fit without a separate adapter or lug swap.
Warranty & Registration: Manufacturer warranty terms for this buss bar are [NEEDS VERIFICATION] — not included in the manufacturer data supplied for this listing. Refer to the "Resources (System Manuals and Warranty)" Tab above on this page for the manufacturer's current warranty documentation. Reach out to us if you can't find what you need there — we always reply back.