This is the 600 Amp current transformer (CT) from Sol-Ark, used to measure current flow so your inverter system can monitor load and generation accurately. It's built for installers and owners setting up or expanding metering on a Sol-Ark inverter installation.
A current transformer is a small but mission-critical piece of your monitoring and metering setup. Accurate current sensing depends on using a CT rated correctly for your system's amperage and matched to the inverter it's paired with. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Ampacity rating: 600A
- Designed for Sol-Ark inverter systems
- Gauge, physical dimensions, and terminal/lug size: [NEEDS VERIFICATION]
- Voltage rating: [NEEDS VERIFICATION]
- NOT verified for use with non-Sol-Ark inverter brands
- NOT rated to exceed 600A continuous measurement
Undersized or mismatched CT ratio settings are a common source of inaccurate power readings and false fault codes on inverter displays. Always confirm the CT ratio configured in your inverter's setup menu matches the physical CT you install — a mismatch causes the system to misreport load or generation, which can mask real overcurrent conditions. Verify actual current flow with a clamp meter before and after installation, and confirm CT orientation (source vs. load side) is correct per the inverter manufacturer's wiring diagram. This keeps your monitoring data accurate and helps prevent nuisance trips or missed overload conditions in line with proper system commissioning practice.
- Rated for 600A current sensing applications
- Matched for use in Sol-Ark inverter installations
- Compact CT design for panel or conduit mounting
- Supports accurate load/generation monitoring for system commissioning
| Spec | Value | Unit |
|---|---|---|
| Ampacity Rating | 600 | A |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
- Fits: Sol-Ark inverter systems requiring 600A current transformer metering
- Does NOT fit: inverter brands other than Sol-Ark (not verified) [NEEDS VERIFICATION]
- Does NOT support continuous current draw beyond 600A
| Compliance Item | Value |
|---|---|
| UL Listing | [NEEDS VERIFICATION] |
| NEC Ampacity Reference | [NEEDS VERIFICATION] |
| IP Rating | [NEEDS VERIFICATION] |
FAQ
What is the amperage rating of this current transformer?
This CT is rated for 600 Amps.
Is this CT compatible with Sol-Ark inverters?
Yes, it is designed for use with Sol-Ark inverter systems.
Will this CT work with other inverter brands?
Compatibility with non-Sol-Ark inverter brands is not verified. [NEEDS VERIFICATION]
What wire gauge or terminal size does this CT use?
Wire gauge and terminal size details are not provided in current manufacturer data. [NEEDS VERIFICATION]
Warranty terms for this part are not included in the current data set. Please refer to the "Resources (System Manuals and Warranty)" Tab above on this page for manufacturer warranty details. [NEEDS VERIFICATION]