This is a single-zone ductless mini split air conditioner for cooling one room or open area without ductwork. It's built for homeowners adding a dedicated cooling zone — a large addition, workshop, or open living space — where a 30,000 BTU capacity is called for.
The Air-Con Eclipse Series pairs a 208-230V outdoor condenser (model ASPCI4H4S30) with a wall-mounted indoor head (model ASPEM4HS30), rated at 30,000 BTU cooling capacity and 18.9 SEER. Wall-mounted indoor units mount above furniture height on an exterior-facing wall and don't require joist-specific framing like a cassette unit would. AHRI-certified performance data is available for the ASPCI4H4S30/ASPEM4HS30 combination. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
System Components
- Outdoor Condenser: Air-Con Eclipse Series, Model ASPCI4H4S30, 208-230V
- Indoor Unit: Air-Con Eclipse Series Wall-Mounted Head, Model ASPEM4HS30
Installation Requirements & Accessories
- Voltage: 208-230V single-phase (not compatible with 115V-only circuits)
- Line Set: 15ft referenced with this listing — confirm exact diameter/length sizing with the installation manual; line set sold separately unless explicitly stated otherwise
- Professional installation by a licensed HVAC technician is required
- Not compatible with 115V-only electrical circuits
- Wall mounting bracket and other mounting hardware for the outdoor unit: [NEEDS VERIFICATION] whether included
Pro-Installer Tip
Flare connections on 208-230V systems like this one are a common point of long-term refrigerant loss if under- or over-torqued. Confirm each flare nut with a digital torque wrench set to the manufacturer's spec rather than "hand-tight plus a turn" — over-torquing deforms the flare face, and under-torquing leaves a slow leak that shows up as reduced capacity or an error code months later. Before charging, pull the line set down below 500 microns with a calibrated micron gauge and hold vacuum to confirm no moisture or non-condensables remain in the system. This work falls under EPA Section 608 refrigerant handling requirements — installation must be performed by an EPA 608-certified technician.
Key Benefits
- Variable-speed inverter-driven compressor for steady, efficient cooling output
- 18.9 SEER efficiency rating
- Wall-mounted indoor unit installs without ceiling or joist modifications
- 30,000 BTU capacity suited to larger rooms or open spaces
- AHRI-certified ODU/IDU matched pairing (ASPCI4H4S30 / ASPEM4HS30)
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 30,000 | BTU/h |
| SEER2 | 18.9 | — |
| Voltage | 208-230 | V |
| Indoor Unit Architecture | Wall Mounted | — |
| Zone Count | 1 | — |
| DIY Status | No — Professional Installation Required | — |
| Line Set Length | 15 | ft |
| Outdoor Unit Model | ASPCI4H4S30 | — |
| Indoor Unit Model | ASPEM4HS30 | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Matched AHRI-certified pairing: outdoor condenser ASPCI4H4S30 with indoor wall-mounted head ASPEM4HS30
- Compatible with dedicated 208-230V single-phase circuits
- Not compatible with 115V-only electrical circuits
- Not a listed match for other Eclipse Series capacity classes (e.g., the 36,000 BTU ASPCI4H4S36R/ASPEM4HS36R pairing uses different specs)
- Line set sizing not confirmed in provided specs — do not assume the referenced 15ft length is included in the box unless confirmed with the seller
FAQ
What breaker size do I need for this system?
Breaker size is [NEEDS VERIFICATION]. This system runs on a 208-230V circuit; confirm exact breaker amperage with the installation manual before rough-in.
Is professional installation required to keep the warranty valid, or is this a true DIY kit?
This is not a DIY pre-charged kit. It uses a standard flare-connection line set that requires vacuum evacuation and professional installation by a licensed HVAC technician to maintain the manufacturer warranty.
Is the line set included, and if not, what size do I need to buy?
A 15ft line set is referenced with this listing per the product title. Exact liquid/suction line diameters are [NEEDS VERIFICATION] — confirm sizing with the installation manual before purchase.
Does this system work in cold climates (low-ambient heating)?
This listing covers the Eclipse Series 30,000 BTU model as an air conditioner. Heating capacity and low-ambient heating performance are [NEEDS VERIFICATION] in the provided specifications.
Compliance & Warranty
Installation by a licensed HVAC professional is required to maintain warranty. This system requires EPA Section 608 certified handling of refrigerant during installation and service. Warranty terms beyond the professional-installation requirement are [NEEDS VERIFICATION] — refer to the "Resources (System Manuals and Warranty)" Tab above for full warranty documentation.