This is a wall-sleeve heat pump and backup-heat unit for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room heating and cooling in one chassis.
The HEH073J25AXXX is Amana's high-efficiency heat pump chassis (family HEH), pairing a reversing heat pump compressor with a 2.5/2.1 kW electric heat strip for supplemental and backup heating below the heat pump's balance point. This configuration is suited to hospitality rooms, additions, and multi-family units needing self-contained, per-room comfort control, and is built to meet or exceed ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Wall sleeve opening: Industry-standard 42 in wide x 16-1/16 in high (Amana WS900E / WS900QW family). Wall Sleeve is NOT included and must be ordered separately.
- Exterior architectural grille (SGK, AGK, or PGK series) is NOT included and must be ordered separately.
- Voltage: 230/208V. Factory power cord is a 6-15P plug rated for 15A circuits, and ships with the LCDI (Leakage Current Detection Interrupter) device required by UL 484 for units under 250V.
- Electric heat installed: 2.5/2.1 kW, single stage. Total system draw with heat: 11.2/10.1A; MCA 14.1A; MOP (breaker) 15A.
- Not compatible with 115V circuits.
- Not for 265V hardwire applications. This is a 230/208V unit — do not attempt to pair it with a 265V sub-base (PTSB4**E series) or hard-wire kit (PTPWHWK4 / disconnect PSHW04A). Those accessories apply only to the 265V commercial sibling chassis, HEH074J.
- Not a drop-in replacement for non-standard or custom sleeve openings — verify existing sleeve dimensions before ordering this chassis.
The technical friction on any PTAC/PTHP retrofit is condensate drainage — the wall sleeve has to shed water outward, not let it pool against the drywall behind the chassis. Set the sleeve level side-to-side, then pitch it approximately 1/4 bubble toward the exterior wall using a torpedo level, per the framing guidance for this chassis (rough opening approx. 42-1/4 in wide x 16-1/4 in minimum high, sleeve extending a minimum of 1/4 in beyond the outside wall face). Skipping this pitch is the single most common cause of drywall water intrusion and mold callbacks on PTAC/PTHP installs. On multi-unit hospitality properties, verify sleeve pitch on every opening during rough-in inspection — don't assume framing crews held tolerance — and document it as part of your property management punch list before drywall closes in behind the sleeve.
Key Benefits
- Heat pump operation delivers a COP of 3.9/3.9, reducing reliance on electric resistance heat in moderate outdoor conditions.
- EER of 13.3/13.7 for efficient cooling performance at 230V/208V respectively.
- Dehumidification rate of 1.7 pints/hour supports guest and occupant comfort in humid climates.
- Fresh air ventilation adjustable from 65-95 CFM for make-up air in tightly sealed rooms.
- R-32 refrigerant, a lower-GWP option compared to legacy refrigerants.
- Single-stage 2.5/2.1 kW backup heat strip supplements the heat pump automatically when outdoor temperatures drop below the heat pump's effective range.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity (230V) | 7,100 | BTU/h |
| Cooling Capacity (208V) | 7,100 | BTU/h |
| Heating Capacity, Heat Pump (230V) | 6,300 | BTU/h |
| Heating Capacity, Heat Pump (208V) | 6,100 | BTU/h |
| Heating Capacity, Electric Heat (230V) | 8,500 | BTU/h |
| Heating Capacity, Electric Heat (208V) | 6,800 | BTU/h |
| Electric Heat Strip Size | 2.5/2.1 | kW |
| Electric Heat Stages | 1 | - |
| EER | 13.3/13.7 | - |
| COP | 3.9/3.9 | - |
| Voltage | 230/208 | V |
| Cooling Amps (compressor only) | 3.0 | A |
| Cooling Watts (compressor only) | 530/515 | W |
| Heating Amps (compressor only) | 3.0 | A |
| Heating Watts (compressor only) | 470/455 | W |
| Total Watts with Electric Heat | 2,570/2,115 | W |
| Total Amps with Electric Heat | 11.2/10.1 | A |
| MCA | 14.1 | A |
| MOP | 15 | A |
| NEMA Plug Type / Power Cord | 6-15P | - |
| CFM Wet, High/Low | 330/245 | CFM |
| CFM Dry, High/Low | 339/339 | CFM |
| Fresh Air Vent CFM | 65-95 | CFM |
| Dehumidification | 1.7 | pints/hr |
| Net Weight | 106 | lb |
| Shipping Weight | 115 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230V and 208V circuits via the factory-installed 6-15P power cord (15A circuit).
- Fits industry-standard 42 in wide x 16-1/16 in high wall sleeve openings (e.g., Amana WS900E / WS900QW).
- Not compatible with 115V circuits.
- Not compatible with 265V hardwire-only installations. Do not order a 265V sub-base (PTSB4**E) or hard-wire kit (PTPWHWK4/PSHW04A) for this model — those pair with the 265V commercial sibling, HEH074J.
- Wall Sleeve is NOT included — order separately.
- Exterior Architectural Grille is NOT included — order separately.
- Not a drop-in fit for non-standard or custom sleeve openings; verify existing opening dimensions first.
| Attribute | Detail |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Power Cord Compliance | LCDI power cord per UL 484 (units under 250V) |
| Overcurrent Protection Type | 15A MOP, standard breaker (non-265V unit) |
| Operating Voltage Range | 230/208V models: min 197V / max 253V |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This PTHP fits the industry-standard 42 in wide x 16-1/16 in high sleeve opening (e.g., Amana WS900E / WS900QW), but the sleeve and exterior architectural grille must be ordered as separate line items.
What breaker size and plug type does this unit require?
With the 2.5/2.1 kW electric heat strip installed, this configuration has a Minimum Circuit Ampacity (MCA) of 14.1A and a Maximum Overcurrent Protection (MOP) of 15A. It ships with a factory-installed 6-15P power cord.
Can this be hardwired for 265V commercial applications?
No. This model is a 230/208V unit and is not rated for 265V. It is not compatible with 265V circuits and should not be paired with a 265V sub-base or hard-wire kit. If you need a 265V commercial version of this chassis, look at the HEH074J instead.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] - installer licensing requirements for warranty validity are not specified in the provided spec data. Refer to the warranty document in the Resources tab for exact terms.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings — confirm your existing sleeve dimensions before ordering.
Warranty & Registration
Manufacturer badge assets for this line confirm a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty. Exact terms, including any commercial hospitality-use limitations versus residential use, are detailed in the full warranty PDF. Refer to the "Resources (System Manuals and Warranty)" Tab above on this page for the complete warranty document before ordering — don't rely on this summary alone if you're planning a commercial hospitality deployment. If anything here doesn't match what you find in that document, ask us before you order — we always reply back.