This is a wall-sleeve air conditioner and electric heater built for hotel rooms, apartments, additions, or any room without central ductwork. It's a self-contained, per-room climate control unit for property managers and homeowners who need reliable cooling and heat in a single chassis.
The PTC073J35AXXX is a standard-model PTAC (Packaged Terminal Air Conditioner) with a single-stage electric heat strip, sized for hospitality rooms, additions, and multi-family units where ductwork isn't practical. It uses R-32 refrigerant and meets or exceeds ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high (e.g., WS900E, WS900QW series).
- Voltage: 230/208V. Valid operating range 197V minimum to 253V maximum.
- Amperage with electric heat installed: 15.5A/14.1A total (230V/208V); MCA 19.5A; MOP 20A.
- Power cord: factory-installed NEMA 6-20P plug with LCDI device per UL 484 (applies to all units under 250V).
- Wall Sleeve NOT included — sold separately.
- Exterior Architectural Grille NOT included — sold separately.
- Not compatible with 115V circuits.
- Not compatible with 265V sub-base or hard-wire installations; the 265V commercial sibling on this chassis is the PTC074J.
- Not a drop-in fit for non-standard sleeve openings outside 42 in x 16-1/16 in.
The most common callback on PTAC installs isn't the electrical — it's water intrusion behind the drywall from a sleeve that was set dead level instead of pitched. Set the sleeve level side-to-side, then pitch it toward the outside wall by about a 1/4-bubble reading on a Torpedo Level so condensate drains outdoors instead of back into the wall cavity. Confirm the sleeve extends a minimum of 1/4 inch beyond the outside wall surface before securing it, per the framing diagram tolerances. On the electrical side, verify the receptacle is a genuine NEMA 6-20R matched to the unit's factory 6-20P cord — don't force-fit a 6-15R receptacle onto a 20A-rated appliance. This is standard property-management best practice for avoiding both water damage claims and NEC receptacle-mismatch violations during inspection.
Key Benefits
- EER of 12.8 (230V) delivers 7,000 BTU/h cooling at 3.2A compressor draw.
- 1.7 pints/hr dehumidification helps manage humidity in guest rooms and living spaces.
- 65 CFM fresh air vent option for make-up air in tightly sealed rooms.
- Single-stage 3.5/3.0 kW electric heat strip delivers up to 12,000 BTU/h supplemental heat at 230V.
- Compact net weight of 106 lb (115 lb shipping) for straightforward chassis handling and replacement.
- R-32 refrigerant and ASHRAE 90.1 compliance for current efficiency standards.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 7,000/7,000 | BTU/h (230V/208V) |
| Heating Capacity | 12,000/9,900 | BTU/h (230V/208V) |
| Electric Heat Strip | 3.5/3.0 | kW (230V/208V) |
| Heat Stages | 1 | stage |
| Voltage | 230/208 | V |
| Compressor Amps | 3.2/3.2 | A |
| Compressor Watts | 545/545 | W |
| Total Heater Watts | 3,570/2,935 | W |
| Total Amps (with Heater) | 15.5/14.1 | A |
| MCA (with Heater) | 19.5 | A |
| MOP (with Heater) | 20 | A |
| Power Cord / NEMA Plug | 6-20P | NEMA plug |
| EER | 12.8/12.8 | BTU/Wh |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 343/309 | CFM |
| Fresh Air Vent CFM | 65 | CFM |
| Dehumidification | 1.7 | pints/hr |
| Net Weight | 106 | lb |
| Ship Weight | 115 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via the factory-installed NEMA 6-20P plug into a matching 6-20R receptacle.
- Fits standard 42-inch x 16-1/16-inch wall sleeve openings, including the WS900E and WS900QW sleeve series.
- Not compatible with 115V circuits.
- Not compatible with 265V sub-base or hard-wire kit setups — for a 265V commercial version of this chassis, see the PTC074J.
- Wall Sleeve NOT included — order separately based on your installation depth and drainage needs.
- Exterior Architectural Grille NOT included — order separately (SGK, AGK, or PGK series).
- Not a drop-in replacement for non-standard or custom sleeve openings.
| Attribute | Detail |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Power Cord Compliance | Factory LCDI power cord per UL 484 (units under 250V) |
| Overcurrent Protection | MOP 20A with electric heat installed |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This chassis fits the industry-standard 42-inch wide x 16-1/16-inch high sleeve opening, such as the WS900E or WS900QW series.
What breaker size and plug type does this unit require?
With the 3.5/3.0 kW electric heat strip installed, this unit requires an MCA of 19.5A and a maximum overcurrent protection (MOP) of 20A. It ships with a factory-installed 6-20P power cord for a NEMA 6-20R receptacle on a 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V model. It is not rated for 265V and does not use the Amana sub-base or hard-wire kit required for 265V units. If you need a 265V commercial unit on this chassis, look at the PTC074J sibling model.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] - installation labor requirements are not specified in the provided spec data. Refer to the manufacturer warranty document in the Resources tab for exact terms.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42-inch wide x 16-1/16-inch high wall sleeve opening. It is not a drop-in fit for custom or non-standard sleeve openings.
Warranty & Registration
This unit carries a 1-Year Parts/Repair-Replace warranty and a 5-Year Parts Limited Warranty on the sealed system, per manufacturer badge documentation. Exact terms, including any distinction between residential and commercial hospitality usage, are detailed in the warranty PDF in the "Resources (System Manuals and Warranty)" Tab above. Ask us before you order if you need help confirming warranty terms for a commercial hospitality install — we always reply back.