This is a wall-sleeve air conditioner and heater built for hotel rooms, apartments, or additions where central ductwork isn't available. It's a 265V commercial unit for property managers and electrical contractors who need self-contained, per-room climate control with a factory-installed electric heat strip.
The PTC094J50AXXX is a 265V packaged terminal air conditioner with a 5.0 kW electric heat strip, built for hospitality and multi-family properties where individual room control matters more than central plant efficiency. Because it operates at 265V, it falls into commercial electrical territory — it is not a plug-and-play residential unit. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high (sleeve sold separately — see below).
- Voltage: 265V. Operating range 239V minimum to 292V maximum.
- Total heater amps: 19.2A. MCA: 23.9A. MOP: 25A.
- Power cord/plug: NEMA 7-30P.
- Wall Sleeve is NOT included. Exterior Architectural Grille is NOT included. Both must be ordered separately.
- Not compatible with 115V circuits.
- Not compatible with 230/208V circuits. The 230/208V version of this chassis is sold under a different model number (PTC093J) — do not attempt to install this 265V unit on a 230/208V circuit or vice versa.
- This unit ships without an LCDI cord device, because LCDI protection under UL 484 applies only to units rated below 250V. A 265V unit instead requires factory-installed cartridge-style time-delay fuses in the required sub-base or hardwire disconnect.
- 265V installation requires an Amana PTSB4**E sub-base or the PTPWHWK4 hardwire kit with PSHW04A disconnect switch — neither is included with the chassis.
- 1 pint/hr per approximately 4,600 BTU of dehumidification capacity — rated at 2 pints/hr for this chassis, useful for humid-climate guest comfort.
- 65 CFM of fresh-air ventilation for make-up air in tightly sealed rooms.
- 11.9 EER on the cooling side for a 9,200 BTU/h chassis.
- Single-stage 5.0 kW electric heat strip delivers 17,100 BTU/h of heating output at 265V.
- Meets or exceeds ASHRAE 90.1 efficiency standards.
- R-32 refrigerant.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 9,200 | BTU/h |
| Heating Capacity (265V) | 17,100 | BTU/h |
| Electric Heat Strip Size | 5.0 | kW |
| Heater Stages | 1 | — |
| EER | 11.9 | BTU/Wh |
| Voltage | 265 | V |
| Compressor Amps | 3.6 | A |
| Compressor Watts | 770 | W |
| Total Heater Watts | 5,070 | W |
| Total Amps (Heater) | 19.2 | A |
| MCA | 23.9 | A |
| MOP | 25 | A |
| NEMA Plug Type | 7-30P | — |
| CFM Wet High/Low | 290/264 | CFM |
| CFM Dry High/Low | 343/343 | CFM |
| Ventilation CFM | 65 | CFM |
| Dehumidification | 2 | pints/hr |
| Net Weight | 102 | lb |
| Shipping Weight | 117 | lb |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | — |
| Exterior Architectural Grille Included | Not Included | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
- Compatible with the industry-standard 42 in x 16-1/16 in wall sleeve opening (e.g., WS900E, WS900QW, WS900SC seacoast, WS900GS sound-isolation sleeves).
- Compatible with 265V commercial circuits, operating range 239V–292V, via NEMA 7-30P plug when paired with an Amana PTSB4**E sub-base, or hardwired using PTPWHWK4 with PSHW04A disconnect.
- Not compatible with 115V circuits.
- Not compatible with 230/208V circuits — order the PTC093J chassis instead for 230/208V installations.
- Wall sleeve NOT included — order separately based on drainage type (standard, seacoast, sound-isolation, or internal-drain variants).
- Exterior architectural grille NOT included — order separately (SGK stamped, AGK extruded aluminum, or PGK polymer).
- Not a drop-in fit for non-standard or custom sleeve openings; rough framing opening is approximately 42-1/4 in wide x 16-1/4 in minimum high.
| Compliance Item | Value | Unit |
|---|---|---|
| Refrigerant Type | R-32 | — |
| ASHRAE Compliance | Meets or exceeds ASHRAE 90.1 | — |
| Overcurrent Protection (265V) | Factory-installed cartridge-style time-delay fuses in sub-base | — |
| LCDI Cord Applicability | Not applicable (unit is 265V, LCDI applies only under 250V per UL 484) | — |
Frequently Asked Questions
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This chassis fits the industry-standard 42 in x 16-1/16 in sleeve opening (e.g., WS900E/WS900QW series), but the sleeve and exterior architectural grille both ship separately.
What breaker size and plug type does this unit require?
This 265V configuration with the 5.0 kW heater requires an MCA of 23.9A and a maximum overcurrent protection (MOP) of 25A, with a NEMA 7-30P power cord.
Can this be hardwired for 265V commercial applications?
Yes, but a 265V unit must use an Amana sub-base (PTSB4**E series) or the PTPWHWK4 hardwire kit paired with the PSHW04A disconnect switch. Neither is included with the unit. This unit does NOT ship with an LCDI power cord, since LCDI protection per UL 484 applies only to units rated under 250V.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
265V circuits and the required sub-base/hardwire kit installation should be performed by a licensed electrician following NEC receptacle and disconnect requirements. Refer to the Resources tab for the manufacturer's exact warranty installation conditions.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is built for the industry-standard 42 in wide x 16-1/16 in high sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per manufacturer badge documentation. Exact terms — including any distinctions between residential and commercial hospitality usage — are detailed in the warranty PDF found in the "Resources (System Manuals and Warranty)" tab above. Review that document before installation, particularly if this unit is going into a commercial hospitality property, since warranty conditions can vary by application. We always reply back if you have questions on coverage — ask us before you order.