null Skip to main content

Amana | 9,000 BTU | PTHP (Packaged Terminal Heat Pump) | 3.7 kW Electric Heat | 265V | PTH094J35AXXX | 20A Power Cord Included

Amana

$1,289.00
(No reviews yet) Write a Review
SKU:
PTH094J35AXXX
UPC:
663051671393
Shipping:
Calculated at Checkout
Direct Factory Delivery: Ships directly from wholesale warehouse with scheduled liftgate delivery & tracking.
Adding to cart… The item has been added

This is a wall-sleeve heat pump and backup-heat system for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and electrical contractors who need self-contained, per-room heating and cooling on a 265V commercial circuit.

The PTH094J35AXXX is a packaged terminal heat pump (PTHP) built for hospitality and multi-family properties where per-room, self-contained climate control replaces central ductwork. It combines a heat pump compressor with 3.7 kW electric backup heat for cold-weather performance, and it meets or exceeds ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.

Critical Fit & Power Requirements

  • Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (industry standard).
  • Voltage: 265V commercial circuit only. Voltage range 239V-292V.
  • Amperage with heater installed: 14.2 total amps / MCA 17.9A / MOP 20A.
  • NEMA Plug Type: 7-20P (matches a 265V, 20-amp receptacle).
  • Wall Sleeve is NOT included — order separately (WS900E, WS900QW, or other listed sleeve model).
  • Exterior Architectural Grille is NOT included — order separately (SGK, AGK, or PGK series).
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — for that voltage class, see the sibling model PTH093J (230/208V), not this unit.
  • This 265V unit does not ship with an LCDI power cord — LCDI protection per UL 484 applies only to units rated under 250V. This unit uses factory-installed cartridge-style time-delay fuses instead.
  • 265V installation requires an Amana sub-base (PTSB4**E series) or the PTPWHWK4 hard-wire kit with PSHW04A disconnect switch — neither is included.
  • Not a drop-in fit for non-standard or custom sleeve openings.
Pro-Installer Tip:

On a 265V hospitality retrofit, the technical friction point is almost always the receptacle: crews sometimes grab a standard 230/208V sub-base off the truck instead of the Amana PTSB4**E rated for 265V, and the 7-20P plug simply won't seat correctly. That mismatch either forces a field improvisation (a fire hazard) or a return trip. Long-term prevention: verify the sub-base or hard-wire kit part number against the chassis voltage before rough-in, not after drywall is closed — the PTPWHWK4/PSHW04A combination is the only accepted hardwire alternative, and mixing components voids the overcurrent protection scheme. Cross-check the receptacle configuration against a NEMA Receptacle Chart before setting the sleeve, and confirm the sleeve itself is pitched roughly 1/4 bubble (per a torpedo level) toward the exterior wall so condensate drains outside rather than migrating back into the sill and drywall. This double-check — voltage/plug match plus drainage pitch — is standard property-management practice for avoiding both electrical callbacks and water-intrusion claims in the first heating season.

Key Benefits

  • Heat pump operation delivers 8,200 BTU/h of heating without engaging electric heat, reducing energy draw in mild weather.
  • 3.7 kW electric heat strip raises total heating output to 12,600 BTU/h at 265V for cold-climate backup.
  • EER of 12.4 and COP of 3.5 support ASHRAE 90.1 compliance for commercial specification.
  • Built-in ventilation feature (65-95 CFM) supports fresh make-up air in tightly sealed guest rooms.
  • 2 pints/hour dehumidification helps manage humidity in occupied rooms without a separate dehumidifier.
  • R-32 refrigerant reflects a lower-GWP refrigerant charge compared to older R-410A platforms.

Technical Table

SpecValueUnit
System TypePTHP (Packaged Terminal Heat Pump)-
Cooling Capacity9,000BTU/h
Cooling Amps3.5A
Cooling Watts725W
EER12.4-
Heating Capacity (Heat Pump, without heater)8,200BTU/h
Heating Amps3.5A
Heating Watts685W
COP3.5-
Heating Capacity at 265V (with Electric Heat)12,600BTU/h
Electric Heat Strip Size3.7kW
Electric Heat Stages1-
Electric Heat Total Watts3,770W
Electric Heat Total Amps14.2A
MCA17.9A
MOP20A
Voltage265V
NEMA Plug Type7-20P-
Power Cord7-20P Power Cord Included-
Required Sub-Base / Hardwire KitPTSB4**E or PTPWHWK4 + PSHW04A (not included)-
Overcurrent Protection DeviceFactory-installed cartridge-style time-delay fuses-
Refrigerant TypeR-32-
CFM Wet (High/Low)290/264CFM
CFM Dry (High/Low)320/320CFM
Ventilation CFM65-95CFM
Dehumidification2pints/hr
Net Weight102lb
Shipping Weight117lb
Wall Sleeve DimensionsStandard 42 x 16-1/16in
Wall Sleeve IncludedNot Included-
Exterior Architectural Grille IncludedNot Included-

Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.

Compatibility & Fitment

  • Compatible with 265V commercial circuits via a 7-20P plug, when paired with the required Amana sub-base or hard-wire kit.
  • Fits standard 42-inch x 16-1/16-inch wall sleeve openings (industry standard).
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — the 230/208V equivalent chassis is model PTH093J, not this unit.
  • Wall Sleeve NOT included — must be purchased separately (e.g., WS900E, WS900QW).
  • Exterior Architectural Grille NOT included — must be purchased separately (SGK, AGK, or PGK series).
  • Not a drop-in replacement for non-standard or custom sleeve openings.

Compliance & Environment

ItemDetail
Refrigerant TypeR-32
Efficiency StandardMeets or exceeds ASHRAE 90.1
Overcurrent Protection (265V)Factory-installed cartridge-style time-delay fuses
LCDI Cord RequirementNot applicable — LCDI cords apply only to units rated under 250V (UL 484)
Voltage Operating Range239V minimum / 292V maximum

FAQ

Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to fit a standard 42-inch by 16-1/16-inch sleeve opening, but the sleeve itself, along with the exterior architectural grille, must be ordered separately.

What breaker size and plug type does this unit require?
With the 3.7 kW electric heat strip installed, this unit has an MCA of 17.9 amps and requires a 20-amp maximum overcurrent protection device (breaker). It ships with a 7-20P power cord for a matching 265V, 20-amp NEMA receptacle.

Can this be hardwired for 265V commercial applications?
Yes, but it requires an Amana-brand sub-base (PTSB4**E series) or the PTPWHWK4 hard-wire kit paired with a PSHW04A disconnect switch. Neither the sub-base nor the hard-wire kit is included with this unit and must be ordered separately.

Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
This is a 265V commercial circuit requiring cartridge-style time-delay fuses and correct sub-base or hardwire kit wiring. Installation should be performed by a licensed electrician familiar with NEC receptacle and overcurrent protection requirements. Refer to the Resources tab for the manufacturer's exact warranty conditions.

Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42-inch wide by 16-1/16-inch high sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.

Warranty & Registration

Manufacturer coverage for this unit includes a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty. Commercial hospitality use and residential use may carry different terms and exclusions under the manufacturer's policy. Exact terms, registration requirements, and any usage limitations are detailed in the warranty PDF — please refer to the "Resources (System Manuals and Warranty)" Tab above on this page before installation.

Wholesale Specifications & Compliance Guarantee

Official MSSD Direct Distribution Data for Amana Item #PTH094J35AXXX

🚚 Wholesale Freight Shipping Structure

  • Palletized Freight Delivery: Securely packaged and strapped to prevent coil or cabinet transit damage.
  • Liftgate Unloading Included: Every system price reflects complete residential or jobsite liftgate unloading services.
  • Terminal Tracking: Direct carrier tracking with scheduled delivery appointment confirmation.

🛡️ EPA Refrigerant & Safety Compliance

  • Low-GWP Mandate Certified: Compliant with 2025–2026 EPA AIM Act guidelines (R-454B / R-32 next-gen refrigerants).
  • Factory Parts Protection: Full manufacturer warranty integrity preserved via authorized wholesale distribution channels.
  • Factory Pre-Charged: Outdoor condensing units engineered and tested for rated line-set lengths.

📜 Manufacturer Warranty Protection

Authorized Dealer Warranty Protection: All Amana systems purchased through MSSD include full factory manufacturer warranty coverage.

📊 System Engineering & Performance Specifications

Product Model Title Amana | 9,000 BTU | PTHP (Packaged Terminal Heat Pump) | 3.7 kW Electric Heat | 265V | PTH094J35AXXX | 20A Power Cord Included
Factory SKU / Part # PTH094J35AXXX
Brand Entity Amana
Wholesale Freight Rate $0.00 (Palletized Liftgate Unloading Included)