Amana | 14,600 BTU | PTHP (Packaged Terminal Heat Pump) | 5.0 kW Electric Heat | 265V | PTH154J50CXXX | 30A Power Cord Included | Seacoast Protected

Amana

$1,463.00
(No reviews yet) Write a Review
SKU:
PTH154J50CXXX
Shipping:
Calculated at Checkout
Direct Factory Delivery: Ships directly from wholesale warehouse with scheduled liftgate delivery & tracking.
Adding to cart… The item has been added

This is a wall-sleeve heat pump and electric backup heater for hotel rooms, apartments, or additions near saltwater where central ductwork isn't available. It's built for property managers and homeowners in coastal environments who need self-contained, per-room heating and cooling with added corrosion protection.

This unit pairs a heat pump compressor with 5.0 kW electric backup heat in a 265V commercial configuration, designed for hospitality corridors, coastal apartment buildings, and additions where central ductwork isn't practical. Seacoast Protected (Feature Code C) construction targets installs near saltwater exposure, where standard coil coatings corrode faster. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.

Critical Fit & Power Requirements

  • Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high.
  • Voltage: 265V. Minimum 239V / maximum 292V operating range.
  • Total amps with 5.0 kW heater installed: 19.2A. MCA: 23.9A. MOP: 25A.
  • Power cord/plug: NEMA 7-30P.
  • Wall Sleeve is NOT included and must be ordered separately (e.g., WS900E, WS900QW, or seacoast-rated WS900SC).
  • Exterior Architectural Grille is NOT included and must be ordered separately (SGK, AGK, or PGK series).
  • Required Sub-Base or Hardwire Kit is NOT included: this 265V unit must be paired with an Amana PTSB4**E sub-base OR the PTPWHWK4 hardwire kit with PSHW04A disconnect switch, sold separately.
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — for that voltage class, see the sibling model PTH153J.
  • Not a drop-in fit for non-standard or custom sleeve openings.

Pro-Installer Tip: Sub-Base Wiring on 265V Chassis

The technical friction on this chassis is that 265V units cannot use the same cord-and-plug sub-base logic as a 230/208V unit — they need the Amana PTSB4**E sub-base or the PTPWHWK4 hardwire kit with the PSHW04A disconnect, and the factory-installed cartridge-style time-delay fuses are matched to that setup. Skipping the correct sub-base, or wiring a hardwire kit without the disconnect, risks an electrical fire from mismatched overcurrent protection, not just a nuisance trip. Verify the sub-base model number against the unit's rating plate before energizing, and confirm the disconnect switch is accessible per NEC 440 requirements for HVAC equipment disconnects. On coastal properties, pair this check with a sleeve pitch inspection — a 1/4-bubble outward pitch on a Torpedo Level at the sleeve, per the standard framing diagram, keeps condensate draining outdoors instead of tracking into interior drywall.

Key Benefits

  • Heat pump operation with 3.0 COP delivers efficient heating down to the unit's rated range before backup heat engages.
  • 5.0 kW electric backup heat supplies 17,100 BTU/h of supplemental heating capacity at 265V for colder snaps.
  • 4.4 pints/hr dehumidification helps manage humidity in coastal and hospitality environments.
  • Built-in fresh air vent (65-95 CFM) supports make-up air needs in guest rooms without separate ventilation equipment.
  • Seacoast Protected corrosion resistance extends service life in salt-air environments compared to standard-coating chassis.
  • 10.4 EER cooling efficiency on a 14,600 BTU/h cooling capacity chassis.
SpecValueUnit
System TypePTHP (Packaged Terminal Heat Pump)-
Corrosion ProtectionSeacoast Protected (Feature Code C)-
Cooling Capacity14,600BTU/h
Heating Capacity (Heat Pump)14,100BTU/h
Heating Capacity (265V Electric Heat)17,100BTU/h
EER10.4-
COP3.0-
Electric Heat Strip Size5.0kW
Electric Heat Stages1-
Total Heater Watts5,070W
Total Amps (with Heater)19.2A
MCA23.9A
MOP25A
Voltage265V
NEMA Plug Type7-30P-
Compressor Cooling Amps6.6A
Compressor Cooling Watts1,405W
Compressor Heating Amps6.6A
Compressor Heating Watts1,375W
CFM Wet (High/Low)400/314CFM
CFM Dry (High/Low)381/381CFM
Fresh Air Vent CFM65-95CFM
Dehumidification Rate4.4pints/hr
Net Weight113lb
Shipping Weight130lb
Refrigerant TypeR-32-
Wall Sleeve DimensionsStandard 42 in x 16-1/16 inin
Wall Sleeve IncludedNot Included-
Exterior Architectural Grille IncludedNot Included-
Required Sub-Base or Hardwire KitAmana PTSB4**E sub-base OR hardwire kit PTPWHWK4 with disconnect PSHW04A (sold separately, required for 265V)-

Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.

Compatibility & Fitment

  • Fits industry-standard 42 in x 16-1/16 in wall sleeve openings.
  • Compatible with 265V circuits at 239V minimum to 292V maximum, via NEMA 7-30P plug or the required sub-base/hardwire kit for hardwired installs.
  • Requires an Amana PTSB4**E sub-base OR PTPWHWK4 hardwire kit with PSHW04A disconnect switch — both sold separately.
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — see sibling model PTH153J for that voltage class.
  • Wall Sleeve NOT included.
  • Exterior Architectural Grille NOT included.
  • Not a drop-in replacement for non-standard or custom sleeve openings.
Compliance ItemDetail
Refrigerant TypeR-32
ASHRAE ComplianceMeets or exceeds ASHRAE 90.1
Overcurrent Protection (265V with heater)Cartridge-style time-delay fuses, factory-installed; MOP 25A
LCDI Power CordNot applicable to this 265V unit; LCDI cords per UL 484 apply only to units under 250V
Voltage Operating Range239V minimum / 292V maximum

FAQ

Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This chassis fits the industry-standard 42 in wide x 16-1/16 in high sleeve opening, but you will need to order a sleeve such as the WS900E, WS900QW, or the seacoast-rated WS900SC separately.

What breaker size and plug type does this unit require?
With the 5.0 kW electric heat installed, this unit requires a Minimum Circuit Ampacity (MCA) of 23.9A and Maximum Overcurrent Protection (MOP) of 25A on a 265V circuit. The factory power cord is a NEMA 7-30P plug configuration.

Can this be hardwired for 265V commercial applications?
Yes. This 265V model must use an Amana sub-base (PTSB4**E series) or the PTPWHWK4 hardwire kit paired with the PSHW04A disconnect switch. Both are sold separately and are required components for this voltage class - a standard cord-and-plug sub-base is not sufficient on its own for hardwire installs.

Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
This is a 265V commercial unit requiring cartridge-style time-delay fuses and a dedicated sub-base or hardwire kit. Installation by a licensed electrician and HVAC professional is strongly recommended to meet NEC code and to keep manufacturer warranty coverage intact. Full terms are in the warranty documentation on the Resources tab.

Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in x 16-1/16 in wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.

Warranty & Registration

This model carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty as documented on the manufacturer's warranty badge. Commercial hospitality use and residential use terms may differ; the full terms, conditions, and registration requirements are in the warranty PDF located in the "Resources (System Manuals and Warranty)" Tab above on this page. We recommend reviewing that document before installation — ask us before you order if anything about coverage is unclear for your application.

Wholesale Specifications & Compliance Guarantee

Official MSSD Direct Distribution Data for Amana Item #PTH154J50CXXX

🚚 Wholesale Freight Shipping Structure

  • Palletized Freight Delivery: Securely packaged and strapped to prevent coil or cabinet transit damage.
  • Liftgate Unloading Included: Every system price reflects complete residential or jobsite liftgate unloading services.
  • Terminal Tracking: Direct carrier tracking with scheduled delivery appointment confirmation.

🛡️ EPA Refrigerant & Safety Compliance

  • Low-GWP Mandate Certified: Compliant with 2025–2026 EPA AIM Act guidelines (R-454B / R-32 next-gen refrigerants).
  • Factory Parts Protection: Full manufacturer warranty integrity preserved via authorized wholesale distribution channels.
  • Factory Pre-Charged: Outdoor condensing units engineered and tested for rated line-set lengths.

📜 Manufacturer Warranty Protection

Authorized Dealer Warranty Protection: All Amana systems purchased through MSSD include full factory manufacturer warranty coverage.

📊 System Engineering & Performance Specifications

Product Model Title Amana | 14,600 BTU | PTHP (Packaged Terminal Heat Pump) | 5.0 kW Electric Heat | 265V | PTH154J50CXXX | 30A Power Cord Included | Seacoast Protected
Factory SKU / Part # PTH154J50CXXX
Brand Entity Amana
Wholesale Freight Rate $0.00 (Palletized Liftgate Unloading Included)