The PolarCool 48″ 120V Belt-Drive Evaporative Cooler (6622-1310) pushes 17,500 CFM across up to 4,000 sq ft using a 1.5 HP 120V motor and NEMA 5-20P plug for buildings without 240V receptacles.
Why Choose This Configuration: Real-World Value & Install Math
- 17,500 CFM Moves Air Farther Across Deep Warehouse Bays: At 17,500 CFM across 4,000 sq ft (compared to 10,000 CFM across 3,200 sq ft on 36 in coolers), one 48 in cooler reaches long assembly benches, distribution lanes, and hangar floors.
- 120V Compatibility Without Rewiring Panels for 240V: Running 18A on 120V AC lets you plug straight into a dedicated 20A NEMA 5-20R commercial branch circuit instead of pulling a 240V line (check your outlet slot before ordering).
- 40 sq ft of 8-Inch Deep CELdek Media + 3-Blade Stainless Prop: Six 12 x 60 x 8 in cooling pads and a 48 in stainless steel prop driven by a 5 ft Power Twist link belt handle industrial duty at just 32 dB.
- Honest Trade-Off: Look closely at three constraints before buying: it draws 18A (exceeds lighter branch circuits rated below the 20A minimum breaker), ships with a 20 ft non-GFCI cord, and has NO low-water pump shutoff on its 13.5-gal sump — you must keep a 3/4 in hose feeding it or turn off the pump toggle whenever water runs low.
Overview
Designed for expansive warehouses, metal fabrication bays, distribution centers, and gyms that only have 120V circuits nearby, the PolarCool 6622-1310 delivers full 48-inch belt-drive output without a 240V drop. Inside the black powder-coated galvanized steel frame, a 1.5 HP single-phase motor spins a 48 in 3-blade stainless steel propeller at low static sound (32 dB) through a 5 ft Power Twist V-belt, controlled by two simple on/off SPST toggle switches for fan and pump.
System Components
- PolarCool 48″ 120V single-speed belt-drive cooler in black powder-coated galvanized steel housing with bottom forklift channels
- 1.5 HP, 1,800 RPM, 120V, 60 Hz motor (3017-3000) driving a 48 in 3-blade stainless steel propeller (6403-5014) via 5 ft Power Twist link belt (1022-2998)
- 120V submersible pump (6422-1310), independent SPST fan/pump toggle switches (3001-2868), and 20 ft 120VAC NEMA 5-20P non-GFCI cord (1501-0105)
- 13.5-gal reservoir with 3/4 in float valve (1009-0107), drain assembly (0006-7010), and six 12 in W x 60 in H x 8 in D CELdek cooling pads (set 6450-6009)
- 4 x 6 in heavy-duty rubber casters (2 fixed, 2 locking swivel — kit 6450-6051) and front cord-wrapping bracket
Installation Requirements & Accessories
- Dedicated 120V, 60 Hz, 20A minimum branch circuit with NEMA 5-20R receptacle (18A draw prohibits sharing circuits or using lighter-rated branch cords below 20A)
- Continuous 3/4 in garden hose feed required during cooling operation because the 13.5-gal tank drains fast at 17 GPH and lacks a low-water pump shutoff
- Check link-belt deflection (about 3/4 in midpoint bow) after the first 30 minutes of startup and again after 24 hours per manual 4801-5035V
- Double bay-door or wide dock clearance: unit stands 73 in W x 74 in H x 35 in D (weighs 625 lbs empty / 738 lbs full; shipping crate 80 x 84 x 44 in at 712 lbs)
- Not Included: Garden water hose, drain hose, GFCI cord protection (ships with non-GFCI NEMA 5-20P plug), Low-Water Shutoff Switch, and 48 in Protective Cover (6421-13016)
- Not Compatible With: Branch receptacles rated below the 20A minimum breaker, 240V circuits, narrow doorways under 35 in, or unventilated rooms
Pro-Installer Tip
Two details keep a 48 in 120V PolarCool out of trouble: continuous water and belt-tension checks. Unlike the 18, 24, and 36 in PolarCools, the 48 in units do not include an automatic low-water shutoff switch, so shutting down or kinking your 3/4 in hose with the pump switch on will burn up the 120V pump — always keep fresh supply connected or snap off the pump toggle first. Check Power Twist belt tension at 30 minutes and 24 hours, maintain open dock doors for cross-ventilation, flush the sump weekly, and operate below 60% RH for crisp temperature drop.
Key Benefits
- Moves 17,500 CFM across up to 4,000 sq ft on single-phase 120V 20A facility power
- Six 8 in deep CELdek pads (40 sq ft surface / 20 cu ft media) saturate massive airflow evenly
- Independent SPST on/off toggle switches keep controls simple for multi-shift warehouse crews
- Galvanized powder-coated cabinet includes bottom forklift channels and 6 in casters for heavy-duty mobility
- Power Twist link belt tightens in minutes by removing links instead of stripping down the propeller shaft
Technical Specifications
| Specification | Value | Unit |
|---|---|---|
| Brand | PolarCool | |
| Series | PolarCool 48 Industrial | |
| Model Number | 6622-1310 | |
| Fan Diameter | 48 | in |
| Propeller Type | 3-Blade Stainless Steel (Part 6403-5014) | |
| Airflow Capacity | 17,500 | CFM |
| Effective Cooling Area | 4,000 | sq ft |
| Drive Type | Belt Drive (5 ft Power Twist Link Belt 1022-2998) | |
| Speed Settings | 1 Speed (Independent Fan/Pump SPST Toggle Switches 3001-2868) | |
| Motor Rating | 1.5 HP, 1,800 RPM, 120V, 60 Hz Single-Phase (Part 3017-3000) | |
| Electrical Supply | 120 | VAC, 60 Hz, 1-Phase |
| Operating Current | 18 | A |
| Power Consumption Rating | 18 | A at 120V, 60 Hz |
| Minimum Circuit Breaker Size | 20 | A |
| Power Cord | 20 ft, 120VAC Non-GFCI with NEMA 5-20P Plug (Part 1501-0105) | |
| Sound Pressure Level | 32 | dB |
| Reservoir Capacity | 13.5 | Gallons |
| Water Consumption Rate | 17 | GPH |
| Rated Water Rate Ambient | At least 90 F | |
| Effective Humidity Ceiling | Below 60% RH | |
| Low-Water Pump Shutoff | Not Equipped | |
| Water Pump | 120V, 60 Hz Submersible Pump (Part 6422-1310) | |
| Cooling Media | 6 Pads – Edge-Coated CELdek 12 in W x 60 in H x 8 in D (Set 6450-6009) | |
| Cooling Media Surface Area | 40 | sq ft |
| Cooling Media Volume | 20 | cu ft |
| Water Inlet Connection | 3/4 in Standard Garden Hose with Float Valve (Part 1009-0107) | |
| Drain Outlet Connection | 3/4 in Garden Hose Adapter (Part 0006-7010) | |
| Housing Material | Galvanized Steel with Black Powder-Coated Finish and Forklift Channels | |
| Mobility / Mounting | 4 x 6 in Heavy-Duty Rubber Casters (2 Fixed, 2 Locking Swivel – Kit 6450-6051) | |
| Unit Dimensions (W x H x D) | 73 x 74 x 35 | in |
| Unit Weight (Empty / Full) | 625 Empty / 738 Full | lbs |
| Shipping Dimensions (W x H x D) | 80 x 84 x 44 | in |
| Shipping Weight | 712 | lbs |
| Manufacturer Warranty | 3 Years Motor, Pump, Electronics and Powder-Coated Housing |
Compatibility & Fitment
- Compatible With: Dedicated 120V, 20A single-phase circuits with NEMA 5-20R receptacles
- Compatible With: Standard 3/4 in garden hose water lines and PolarCool 90-Gal Water Cart (6540-1809)
- Compatible With: 48 in Pad Set of 6 (6450-6009), 48 in Protective Cover (6421-13016), and Power Twist Belt (1022-2998)
- Not Compatible With: Branch receptacles rated below the 20A minimum breaker or light-gauge extension cords (causes motor thermal cutout)
- Not Compatible With: 230V/240V outlets or 6422-0647 / 3017-3099 240V parts
- Not Compatible With: Unattended dry-tank operation (no low-water pump shutoff installed)
- Not Included: GFCI inline plug protection (non-GFCI NEMA 5-20P cord fitted)
- Not Included: Automatic low-water pump shutoff switch
- Not Included: Water supply hose, drain hose, and 48 in Cover (6421-13016)
- Not Rated For: Standard lighting or receptacle branch circuits rated below the 20A minimum breaker
- Not Rated For: Enclosed spaces lacking cross-ventilation or consistently above 60% RH
- Not Rated For: Single-man doorways under 35 in wide
Frequently Asked Questions
Can you plug the 120V PolarCool 48 in (6622-1310) into a standard household outlet under 20 amps?
No. The 1.5 HP motor draws 18A at 120V, ships with a NEMA 5-20P 20-amp plug, and manual 4801-5035V requires a 20A minimum breaker.
Does the 48 in 6622-1310 shut the water pump off automatically when water runs low?
No. Unlike the 36 in Pro and Classic models, manual 4801-5035V notes the 48 in series is not equipped with a low-water shutoff, so keep a 3/4 in water hose attached or turn off the pump switch before draining.
How much space and water does the 6622-1310 need?
It delivers 17,500 CFM across up to 4,000 sq ft and consumes about 17 GPH in 90 F or hotter spaces, fed continuously into its 13.5-gallon reservoir.
What maintenance does the belt drive on the 48 in PolarCool require?
Check the Power Twist V-belt for 3/4 in deflection after the first 30 minutes and 24 hours of runtime, then periodically remove links if needed to hold tension.
Compliance & Warranty
Operation on a properly grounded circuit matching the nameplate voltage and amperage rating, along with routine water and cooling-pad maintenance per the PolarCool Owner’s Manual, is required to maintain warranty coverage. PolarCool (HH Technologies, Inc.) warrants the motor, electrical components, and black powder-coated housing of the 6622-1310 for 3 years from invoice date against material or workmanship defects upon factory-authorized inspection (excluding wear items like belts and pads, labor, and shipping). Have a question on sizing, electrical hookup, or replacement parts before you order? Reach out anytime — we always reply back.











Reviews
There are no reviews yet.