This is a wall-sleeve air conditioner and electric heater built for hotel rooms, coastal apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners near seacoast environments who need self-contained, per-room climate control with added corrosion protection.
The PTC073J25CXXX is a Standard Cooler PTAC chassis with a 2.5/2.1 kW electric heat strip, built for hospitality and residential sleeve installations that need 7,000 BTU cooling and factory-matched electric heat in one packaged unit. This model carries Feature Code C, meaning it includes seacoast corrosion protection for coastal or high-humidity installations, and it meets or exceeds ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (industry-standard PTAC sleeve size).
- Voltage: 230/208V. Minimum 197V / maximum 253V operating range.
- Total amps with heater: 11.2/10.1A. MCA: 14.1A. MOP: 15A.
- Power cord/plug: 6-15P NEMA plug, factory-installed LCDI power cord per UL 484 (applies to all units under 250V).
- Wall Sleeve is NOT included — sold separately (e.g., WS900E, WS900QW, or WS900SC for additional seacoast protection).
- Exterior Architectural Grille is NOT included — sold separately (SGK, AGK, or PGK series).
- Not compatible with 115V circuits.
- Not compatible with 265V hardwire-only applications — see the PTC074J (265V commercial sibling) if you need 265V, which requires an Amana sub-base (PTSB4**E) or hard-wire kit PTPWHWK4 with disconnect PSHW04A.
- Not a drop-in replacement for non-standard or custom sleeve openings — verify existing sleeve dimensions before ordering.
The most common callback on PTAC replacements isn't the compressor — it's water damage inside the wall cavity months after install. When you set the sleeve, pitch it 1/4 bubble toward the outside wall using a torpedo level; a level or reverse-pitched sleeve lets condensate track back into the room-side drywall instead of draining outdoors. Confirm the pitch before you seal or insulate around the sleeve, not after. On the electrical side, verify the receptacle matches the 6-15P plug on this unit against a NEMA receptacle chart before energizing — a mismatched or improvised adapter on a 230/208V circuit is a common source of nuisance trips and, over time, arcing at the plug face. Both of these checks take under five minutes and satisfy standard property management commissioning practice for PTAC turnover between guests or tenants.
Key Benefits
- EER rating of 12.8/12.8 for consistent cooling efficiency at rated voltage.
- Dehumidification rate of 1.7 pints per hour supports guest and occupant comfort in humid climates.
- 65 CFM vent capability provides fresh make-up air option for the conditioned space.
- Single-stage 2.5/2.1 kW electric heat strip delivers supplemental heating without a separate system.
- Seacoast corrosion protection (Feature Code C) extends coil and cabinet life in coastal air.
- R-32 refrigerant with ASHRAE 90.1 compliance.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 7,000/7,000 | BTU/h |
| Heating Capacity (230V) | 8,500 | BTU/h |
| Heating Capacity (208V) | 6,800 | BTU/h |
| Electric Heat Strip Size | 2.5/2.1 | kW |
| Heater Stages | 1 | - |
| EER | 12.8/12.8 | BTU/Wh |
| Voltage | 230/208 | V |
| Compressor Amps | 3.2/3.2 | A |
| Compressor Watts | 545/545 | W |
| Total Heater Watts | 2,570/2,115 | W |
| Total Amps (with heater) | 11.2/10.1 | A |
| MCA (with heater) | 14.1 | A |
| MOP (with heater) | 15 | A |
| NEMA Plug Type | 6-15P | - |
| Dehumidification Rate | 1.7 | pt/h |
| Ventilation CFM | 65 | CFM |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 343/309 | CFM |
| Net Weight | 106 | LB |
| Ship Weight | 115 | LB |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Sleeve Included | Not Included | - |
| Exterior Architectural Grille | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Fits standard 42-inch wide x 16-1/16-inch high PTAC wall sleeve openings, including WS900E, WS900QW, and WS900SC (seacoast triple-protected) sleeve models.
- Compatible with 230/208V circuits via 6-15P NEMA plug, operating within a 197V minimum to 253V maximum range.
- Not compatible with 115V circuits.
- Not suitable for 265V hardwire-only applications — this chassis's 265V commercial sibling is the PTC074J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A, sold separately.
- Wall Sleeve NOT included — must be ordered separately.
- Exterior Architectural Grille NOT included — must be ordered separately.
- Not a drop-in replacement for non-standard or custom sleeve openings; verify existing rough opening dimensions (approx. 42-1/4 in wide x 16-1/4 in minimum high) before ordering.
| Spec | Value |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Power Cord Compliance | LCDI power cord, UL 484 (units under 250V) |
| Voltage Operating Range | 197V minimum / 253V maximum (230/208V models) |
| Overcurrent Protection | 15A MOP with heater installed |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to fit a standard 42-inch wide x 16-1/16-inch high PTAC sleeve opening, such as the WS900E or WS900QW.
What breaker size and plug type does this unit require?
This configuration ships with a 6-15P plug and requires an MCA of 14.1 amps with a 15-amp maximum overcurrent protection (MOP), based on the 2.5/2.1 kW electric heat strip installed.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V unit and is not rated for 265V circuits. If you need a 265V commercial unit on this chassis, look at the PTC074J sibling model, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A, sold separately, along with factory-installed cartridge-style time-delay fuses.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42-inch wide x 16-1/16-inch high PTAC wall sleeve opening. The rough framing opening should be approximately 42-1/4 inches wide by 16-1/4 inches minimum high.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] - installer licensing requirements for warranty validity are not specified in the source documentation provided. Refer to the warranty PDF in the Resources tab for exact terms.
Warranty & Registration
This unit is covered by a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per manufacturer badge documentation. Exact terms, including any distinctions between commercial hospitality and residential usage limits, are detailed in the warranty PDF located in the "Resources (System Manuals and Warranty)" Tab above. Ask us before you order if you need help confirming coverage for a specific hospitality or multi-unit property application — we always reply back.