This is a wall-sleeve air conditioner with electric heat for hotel rooms, apartments, additions, or any space without central ductwork. It's built for property managers and homeowners who need self-contained, per-room cooling and heating that plugs into a standard 230/208V circuit.
The PTC073J25AXXX is a standard-model PTAC built for hospitality rooms, multi-family units, and additions where ductwork isn't practical. It uses R-32 refrigerant and meets or exceeds ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall Sleeve: Fits industry-standard 42 in wide x 16-1/16 in high opening (e.g., WS900E, WS900QW).
- Voltage: 230/208V. Minimum 197V / maximum 253V per manufacturer voltage limits.
- Amperage: MCA 14.1A, MOP 15A (with 2.5/2.1 kW electric heat installed).
- NEMA Plug Type: 6-15P, factory-installed LCDI power cord per UL 484.
- Wall Sleeve is NOT included and is sold separately.
- Exterior Architectural Grille is NOT included and is sold separately.
- Not compatible with 115V circuits.
- Not compatible with 265V circuits, sub-bases, or hard-wire kits — see the PTC074J for the 265V commercial version of this chassis.
- Not a drop-in fit for non-standard or custom sleeve openings; verify rough opening dimensions before ordering.
A recurring callback on PTAC installs is water intrusion at the drywall below the sleeve, usually traced back to a level or improperly pitched sleeve. The wall sleeve must be pitched approximately 1/4 bubble toward the outside wall using a torpedo level, while remaining level side-to-side, so condensate drains outward instead of pooling against the interior wall cavity. Skipping this step lets moisture wick into drywall over months, well after the installer has left the job. Confirm pitch with a torpedo level at both the front and rear of the sleeve rail before securing it into the rough opening, and reference the framing detail (rough opening approx. 42-1/4 in wide x 16-1/4 in minimum high, sleeve extending a minimum of 1/4 in beyond the outside wall). This is standard property-management practice for hospitality rooms subject to routine PTAC turnover inspections.
Key Benefits
- EER of 12.8 (230V) / 12.8 (208V) for verified cooling efficiency at rated conditions.
- Dehumidification rate of 1.7 pints/hr to help manage room humidity load.
- Built-in fresh air vent rated at 65 CFM for make-up air in occupied rooms.
- Single-stage 2.5/2.1 kW electric heat strip provides supplemental heating without a separate furnace.
- R-32 refrigerant construction, meeting or exceeding ASHRAE 90.1 standards.
- Factory-installed LCDI power cord (UL 484) simplifies plug-and-play installation on 230/208V circuits.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity (230V/208V) | 7,000/7,000 | BTU/h |
| Heating Capacity (230V) | 8,500 | BTU/h |
| Heating Capacity (208V) | 6,800 | BTU/h |
| Electric Heat Strip Size | 2.5/2.1 | kW (230V/208V) |
| Heater Stages | 1 | - |
| EER | 12.8/12.8 | BTU/Wh |
| Voltage | 230/208 | V |
| Compressor Amps | 3.2/3.2 | A |
| Compressor Watts | 545/545 | W |
| Total Amps (with heat) | 11.2/10.1 | A |
| Total Watts (with heat) | 2,570/2,115 | W |
| MCA | 14.1 | A |
| MOP | 15 | A |
| NEMA Plug Type | 6-15P | - |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 343/309 | CFM |
| Fresh Air Vent | 65 | CFM |
| Dehumidification | 1.7 | pints/hr |
| Net Weight | 106 | lb |
| Shipping Weight | 115 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via a NEMA 6-15P plug.
- Fits standard 42-inch x 16-1/16-inch wall sleeve openings (e.g., WS900E, WS900QW, WS900SC, WS900GS).
- Rough framing opening should be approximately 42-1/4 in wide x 16-1/4 in minimum high, with the sleeve extending a minimum of 1/4 in beyond the outside wall.
- Not compatible with 115V circuits.
- Not compatible with 265V circuits, sub-bases, or hard-wire kits; for 265V commercial applications, see the PTC074J chassis sibling.
- Wall Sleeve NOT included — must be ordered separately.
- Exterior Architectural Grille NOT included — must be ordered separately.
- Condensate drain kit (DK900D or DK900QW, matched to sleeve model) sold separately.
- Not a drop-in replacement for non-standard or custom sleeve openings.
| Compliance / Environmental Item | Value |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Power Cord Compliance | LCDI power cord, UL 484 (units under 250V) |
| Overcurrent Protection | 15A MOP; standard breaker/fuse protection (no cartridge time-delay fuse requirement at this voltage) |
| Voltage Operating Range | 197V minimum / 253V maximum |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to install into an industry-standard 42 in wide x 16-1/16 in high wall sleeve opening, such as the WS900E or WS900QW.
What breaker size and plug type does this unit require?
This unit ships with a 6-15P power cord and requires a maximum overcurrent protection (MOP) of 15 amps. Minimum circuit ampacity (MCA) is 14.1 amps on a 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This unit is rated 230/208V only and is not designed for 265V operation. The 265V commercial version of this chassis is the PTC074J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect switch PSHW04A, sold separately.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] — installer licensing requirements for warranty validity are not specified in the provided data. Refer to the warranty document in the Resources tab for exact terms.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening. The rough framing opening should be approximately 42-1/4 in wide x 16-1/4 in minimum high.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per manufacturer badge documentation. Exact terms, including any distinctions between commercial hospitality use and residential use, are detailed in the warranty PDF under the "Resources (System Manuals and Warranty)" Tab above — refer there before relying on warranty coverage for a specific application. If you have questions about coverage for your property type, ask us before you order — we always reply back.