This is a wall-sleeve air conditioner and electric-heat unit for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and commercial installers who need self-contained, per-room climate control on a 265V electrical circuit.
The PTC074J25AXXX is a 265V packaged terminal air conditioner with a 2.5 kW electric heat strip, built for hospitality corridors, additions, and multi-unit properties where a dedicated 265V circuit is already in place. Amana PTAC chassis are evaluated under AHRI-referenced test procedures and meet or exceed ASHRAE 90.1 efficiency requirements. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (WS900E / WS900QW family)
- Voltage: 265V, operating range 239V minimum to 292V maximum
- Total heat amps: 9.7A; MCA: 12.2A; MOP (fuse size): 15A time-delay, cartridge-style, factory-installed
- Power cord: 7-20P plug configuration
- Wall Sleeve is NOT included and must be ordered separately.
- Exterior Architectural Grille is NOT included and must be ordered separately.
- Requires an Amana PTSB4**E sub-base or PTPWHWK4 hardwire kit with PSHW04A disconnect switch — neither is included with this chassis.
- Not compatible with 115V circuits
- Not compatible with 230/208V circuits — for that voltage class, the correct chassis is the sibling model PTC073J
- Not a drop-in replacement for non-standard or custom sleeve openings
Key Benefits
- EER of 13 for the cooling-only compressor circuit
- 1.7 pints/hour of dehumidification at rated conditions
- 65 CFM of dedicated ventilation (fresh air) capability
- 339 CFM dry-coil airflow at both high and low fan speeds for consistent room circulation
- R-32 refrigerant, in line with current low-GWP refrigerant transition standards
- Meets or exceeds ASHRAE 90.1 efficiency requirements
Technical Table
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 7,000 | BTU/h |
| Heating Capacity (265V) | 8,500 | BTU/h |
| Electric Heat Strip | 2.5 | kW |
| Heat Stages | 1 | - |
| EER | 13 | - |
| Voltage | 265 | V |
| Voltage Operating Range | 239V min / 292V max (265V class) | - |
| Compressor Amps | 2.7 | A |
| Compressor Watts | 535 | W |
| Total Heat Amps | 9.7 | A |
| Total Heat Watts | 2,570 | W |
| MCA | 12.2 | A |
| MOP (Overcurrent Protection) | 15 | A |
| NEMA Plug Type / Power Cord | 7-20P | - |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 339/339 | CFM |
| Ventilation CFM | 65 | CFM |
| Dehumidification | 1.7 | pints/hr |
| Net Weight | 103 | LB |
| Ship Weight | 115 | LB |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | Standard 42 in W x 16-1/16 in H | - |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
| Required Sub-Base or Hardwire Kit | Amana PTSB4**E sub-base or PTPWHWK4 hardwire kit with PSHW04A disconnect (Not Included) | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening (WS900E / WS900QW family)
- Compatible with 265V circuits only, within a 239V–292V operating range, via a 7-20P power cord
- Requires an Amana PTSB4**E sub-base or PTPWHWK4 hardwire kit with PSHW04A disconnect — sold separately
- Not compatible with 115V circuits
- Not compatible with 230/208V circuits — see sibling chassis PTC073J for that voltage class
- Wall Sleeve NOT included
- Exterior Architectural Grille NOT included
- Not a drop-in fit for non-standard or custom sleeve openings
Compliance & Environment
| Spec | Value |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Overcurrent Protection (265V) | Cartridge-style time-delay fuses, factory-installed |
| Power Cord Standard | Not applicable at 265V — sub-base/hardwire kit required; LCDI cord applies only to units under 250V |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit fits the industry-standard 42 in wide x 16-1/16 in high sleeve opening (WS900E / WS900QW family).
What breaker size and plug type does this unit require?
With the 2.5 kW electric heat installed, this unit has an MCA of 12.2A and requires a 15A time-delay fuse overcurrent device (MOP). It ships with a 7-20P power cord for a 265V circuit.
Can this be hardwired for 265V commercial applications?
Yes. All 265V models must use an Amana brand sub-base (PTSB4**E series) or the PTPWHWK4 hardwire kit with PSHW04A disconnect switch. Both are sold separately from the chassis.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
265V circuits fall outside standard household wiring and require a qualified electrician for sub-base or hardwire kit installation. Refer to the warranty documentation in the Resources tab for exact installer requirements.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in x 16-1/16 in wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty. Exact terms, including any distinctions between residential and commercial hospitality usage, are detailed in the warranty PDF found under the "Resources (System Manuals and Warranty)" Tab above. Ask us before you order if you need help confirming coverage for a commercial hospitality deployment — we always reply back.