This is a wall-sleeve heat pump air conditioner and heater for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room climate control with electric backup heat for cold-weather performance.

The PTH074J25AXXX is Amana's standard PTHP chassis, combining a heat pump compressor with 2.5 kW electric backup heat for properties needing supplemental heating below the heat pump's practical operating range. This configuration is common in hospitality corridors, additions, and multi-family units where a dedicated wall sleeve replaces central ductwork. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.

  • Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (industry-standard PTAC sleeve size).
  • Voltage: 265V commercial. Minimum 239V / maximum 292V per Amana's operating range.
  • Total amperage with 2.5 kW heater installed: 9.7A. MCA 12.2A. MOP (max breaker/fuse) 15A.
  • Power cord/plug: 7-20P.
  • Wall Sleeve is NOT included — order separately (e.g., Amana WS900E, WS900QW, or a deep/seacoast/sound-isolation variant matching your wall depth).
  • Exterior Architectural Grille is NOT included — order separately (SGK, AGK, or PGK series).
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — the 230/208V version of this chassis is the PTH073J, sold as a separate model/plug configuration.
  • 265V models require an Amana sub-base (PTSB4**E) or hardwire kit (PTPWHWK4) with disconnect switch (PSHW04A). Neither is included with this unit.
  • Not a drop-in fit for non-standard or custom sleeve openings — confirm sleeve depth and dimensions before ordering.
Pro-Installer Tip:

On 265V hospitality retrofits, the most common callback isn't the chassis — it's a wrong-plug receptacle installed before the unit arrives on site. Verify the NEMA 7-20 receptacle configuration against the unit's 7-20P cord using a NEMA receptacle chart before the electrician closes the wall, since 265V circuits use a different pin configuration than 230/208V rooms down the hall. Confirming this early prevents an electrical mismatch that otherwise means re-pulling wire or swapping the receptacle after drywall and trim are finished. While you're at the sleeve, set your torpedo level side-to-side and pitch it roughly 1/4 bubble toward the exterior — this keeps condensate draining outdoors instead of migrating back into the wall cavity and softening the drywall over time. Both steps line up with NEC receptacle-matching practice and standard property-management commissioning checklists for PTAC/PTHP turnover.

Key Benefits

  • Heat pump operation rated at COP 3.5, supplementing with 2.5 kW electric heat for a combined 8,500 BTU/h heating capacity at 265V.
  • EER 12.5 cooling efficiency on a 7,300 BTU/h cooling capacity chassis.
  • Dehumidification rate of 1.7 pints/hr for shoulder-season moisture control.
  • Built-in ventilation CFM range of 65-95 for fresh-air makeup in sealed rooms.
  • R-32 refrigerant, meeting or exceeding ASHRAE 90.1 efficiency standards.
  • Compact net weight of 103 lb (115 lb shipping) simplifies chassis swaps in occupied buildings.
SpecValueUnit
Cooling Capacity7,300BTU/h
Heating Capacity (Heat Pump)6,500BTU/h
Heating Capacity (265V w/ Electric Heat)8,500BTU/h
Electric Heat Strip Size2.5kW
Electric Heat Stages1-
EER12.5-
COP3.5-
Voltage265V
Total Amps (with heater)9.7A
MCA12.2A
MOP15A
NEMA Plug Type7-20P-
Cooling Amps (compressor only)2.8A
Cooling Watts (compressor only)585W
Heating Amps (compressor only)2.8A
Heating Watts (compressor only)545W
Total Watts (with heater)2,570W
CFM Wet (High/Low)330/245CFM
CFM Dry (High/Low)344/344CFM
Ventilation CFM65-95CFM
Dehumidification Rate1.7pints/hr
Net Weight103lb
Shipping Weight115lb
Wall Sleeve DimensionsStandard 42 x 16-1/16in
Wall Sleeve IncludedNot Included-
Exterior Architectural Grille IncludedNot Included-

Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.

Compatibility & Fitment

  • Fits the industry-standard 42 in x 16-1/16 in wall sleeve opening (Amana WS900E, WS900QW, and compatible deep/seacoast/sound-isolation variants).
  • Compatible with 265V commercial electrical circuits within the 239V-292V operating range, using the included 7-20P power cord.
  • Requires an Amana PTSB4**E sub-base or PTPWHWK4 hardwire kit with PSHW04A disconnect switch — order separately, not included.
  • Not compatible with 115V circuits.
  • Not compatible with 230/208V circuits — use the PTH073J chassis instead for 230/208V applications.
  • Wall Sleeve NOT included. Exterior Architectural Grille NOT included. Both must be ordered separately.
  • Not a drop-in replacement for non-standard or custom sleeve openings — verify depth before purchase.
Compliance ItemDetail
Refrigerant TypeR-32
Efficiency StandardMeets or exceeds ASHRAE 90.1
Electrical Compliance (265V)Requires factory-installed cartridge-style time-delay fuses; sub-base or hardwire kit with disconnect required per Amana installation notes
LCDI Cord ApplicabilityNot applicable to this 265V unit — LCDI power cords per UL 484 apply only to units under 250V

FAQ

Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This chassis fits the industry-standard 42 in x 16-1/16 in wall sleeve opening (for example, the Amana WS900E or WS900QW sleeve families). The exterior architectural grille is also sold separately.

What breaker size and plug type does this unit require?
With the 2.5 kW electric heat installed, this 265V unit has an MCA of 12.2A, a maximum overcurrent protection (MOP) rating of 15A, and ships with a 7-20P power cord. It requires factory-installed cartridge-style time-delay fuses at 265V per Amana's electrical notes.

Can this be hardwired for 265V commercial applications?
Yes, but only with the required Amana equipment. All 265V models must be installed with either an Amana PTSB4**E sub-base or the PTPWHWK4 hardwire kit paired with the PSHW04A disconnect switch. Neither is included with this unit.

Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] — installer licensing requirements for warranty validity are not specified in the provided source data. Refer to the warranty PDF in the Resources tab for exact terms.

Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in x 16-1/16 in wall sleeve opening. It is not a drop-in fit for non-standard or custom-sized sleeve openings.

Warranty & Registration

This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty on the sealed system, per Amana's published warranty badge terms. Exact coverage terms, including any distinction between residential and commercial hospitality usage, are detailed in the warranty PDF — refer to the "Resources (System Manuals and Warranty)" Tab above on this page for the full document before you order. If anything in that document raises a question about your specific install, ask us before you order — we always reply back.

Wholesale Specifications & Compliance Guarantee

Official MSSD Direct Distribution Data for Amana Item #PTH074J25AXXX

🚚 Wholesale Freight Shipping Structure

  • Palletized Freight Delivery: Securely packaged and strapped to prevent coil or cabinet transit damage.
  • Liftgate Unloading Included: Every system price reflects complete residential or jobsite liftgate unloading services.
  • Terminal Tracking: Direct carrier tracking with scheduled delivery appointment confirmation.

🛡️ EPA Refrigerant & Safety Compliance

  • Low-GWP Mandate Certified: Compliant with 2025–2026 EPA AIM Act guidelines (R-454B / R-32 next-gen refrigerants).
  • Factory Parts Protection: Full manufacturer warranty integrity preserved via authorized wholesale distribution channels.
  • Factory Pre-Charged: Outdoor condensing units engineered and tested for rated line-set lengths.

📜 Manufacturer Warranty Protection

Authorized Dealer Warranty Protection: All Amana systems purchased through MSSD include full factory manufacturer warranty coverage.

📊 System Engineering & Performance Specifications

Product Model Title Amana | 7,300 BTU | PTHP (Packaged Terminal Heat Pump) | 2.5 kW Electric Heat | 265V | PTH074J25AXXX | 20A Power Cord Included
Factory SKU / Part # PTH074J25AXXX
Brand Entity Amana
Wholesale Freight Rate $0.00 (Palletized Liftgate Unloading Included)