This is a wall-sleeve air conditioner and electric heater for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room cooling and heating with a standard 230/208V circuit.
The DRY093J35AXXX is an R-32 PTAC unit from Amana's enhanced dehumidification J-series, built for hospitality rooms, additions, and multifamily units that need standalone, per-room comfort control. It meets or exceeds ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
- Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (industry-standard PTAC sleeve size)
- Voltage: 230/208V
- Amperage with heater installed: 15.5/14.1A total amps; MCA 19.5A; MOP 20A
- NEMA plug type: 6-20P (factory-installed power cord)
- Wall Sleeve is NOT included and must be purchased separately.
- Exterior Architectural Grille is NOT included and must be purchased separately.
- Not compatible with 115V circuits
- Not compatible with 265V hardwire/sub-base setups — the 265V commercial version of this chassis is sold as model DRY094J
- Not a drop-in fit for non-standard or custom sleeve openings — verify dimensions against your existing sleeve before ordering
The most common callback on PTAC installs isn't the electrical — it's water intrusion around the sleeve. When you set the wall sleeve for this chassis, pitch it 1/4 bubble toward the outside wall using a torpedo level; a level or reverse-pitched sleeve pushes condensate back into the wall cavity instead of draining outdoors, which leads to drywall rot and mold behind the unit months after the guest complaints stop. Confirm the sleeve extends a minimum of 1/4 in beyond the exterior wall face before you seal the rough opening. This matches Amana's framing guidance for the WS900 series and is standard practice under most property management preventive-maintenance checklists — don't skip the level check because the sleeve "looks" square.
- 2.6 pints/hr dehumidification for enhanced humidity control in guest rooms and multifamily units
- 65 CFM dedicated fresh air (make-up air) vent setting
- 11.8/11.8 EER rating on the cooling side (230V/208V)
- Single-stage 3.5/3.0 kW electric heat strip for supplemental winter heating
- R-32 refrigerant, ASHRAE 90.1 compliant
- Standard 230/208V factory power cord — no hardwiring or sub-base required
| Spec | Value | Unit |
|---|---|---|
| System Type | PTAC with Electric Heat | — |
| Voltage | 230/208 | V |
| Cooling Capacity | 9,000/9,000 | BTU/h |
| Compressor Amps | 4.3 | A |
| Compressor Watts | 760/760 | W |
| EER | 11.8/11.8 | — |
| MCA (Cooling Only, No Heater) | 4.9 | A |
| CFM Wet (High/Low) | 290/264 | CFM |
| CFM Dry (High/Low) | 321/295 | CFM |
| Fresh Air Vent CFM | 65 | CFM |
| Dehumidification | 2.6 | pints/hr |
| Net Weight | 105 | LBS |
| Ship Weight | 120 | LBS |
| Electric Heat Size | 3.5/3.0 | kW |
| Heating Capacity (230V) | 12,000 | BTU/h |
| Heating Capacity (208V) | 9,900 | BTU/h |
| Heater Total Watts | 3,570/2,935 | W |
| Heater Total Amps | 15.5/14.1 | A |
| MCA (With Heater) | 19.5 | A |
| MOP (Max Overcurrent Protection) | 20 | A |
| Power Cord / NEMA Plug Type | 6-20P | — |
| Refrigerant Type | R-32 | — |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | — |
| Exterior Architectural Grille Included | Not Included | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
- Compatible with 230/208V circuits via NEMA 6-20 plug configuration
- Fits standard 42-inch x 16-1/16-inch wall sleeve openings (e.g., WS900E / WS900QW series)
- Not compatible with 115V circuits
- Not compatible with 265V hardwire or sub-base installations — see sibling model DRY094J for the 265V commercial version of this chassis
- Wall Sleeve NOT included — order separately
- Exterior Architectural Grille NOT included — order separately
- Not a drop-in replacement for non-standard or custom sleeve openings
| Attribute | Detail |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Electrical Compliance | Factory power cord with LCDI device per UL 484 (applies to units under 250V) |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to fit the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening (e.g., WS900E / WS900QW series), but the sleeve itself must be purchased separately.
What breaker size and plug type does this unit require?
This configuration ships with a 6-20P power cord for 230/208V circuits. With the 3.5/3.0 kW electric heat installed, the minimum circuit ampacity (MCA) is 19.5A and the maximum overcurrent protection (MOP) is 20A, so it requires a dedicated 20A, 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V model with a factory-installed 6-20P power cord. It is not rated for 265V and should not be paired with a 265V sub-base or hard-wire kit. The 265V commercial version of this chassis is sold as model DRY094J.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
Amana's warranty terms and installation requirements are detailed in the manufacturer warranty document. Refer to the Resources (System Manuals and Warranty) tab above for the exact language on qualified-installer requirements.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is built to the industry-standard 42 in x 16-1/16 in wall sleeve dimension. It is not a fit for non-standard or custom sleeve openings without verifying dimensions first.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty from Amana. Exact terms, including any distinctions between residential and commercial/hospitality usage, are set out in the manufacturer warranty document. Refer to the "Resources (System Manuals and Warranty)" Tab above on this page for the full warranty language before you order — ask us if anything in it is unclear and we'll help you sort it out.