This is a wall-sleeve air conditioner and heater for hotel rooms, apartments, additions, or any room where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room climate control with a straightforward 230/208V electrical hookup.
The HEC093J35AXXX is a High-Efficiency Cooler PTAC built for hospitality rooms, additions, and multi-family units where ductwork isn't practical. It meets or exceeds ASHRAE 90.1 efficiency standards for packaged terminal equipment. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: Standard 42 in wide x 16-1/16 in high (industry-standard PTAC opening)
- Voltage: 230/208V (dual-rated; slashed values reflect 230V/208V ratings)
- Total heater amps: 15.5/14.1A; MCA: 19.5A; MOP: 20A
- Power cord: NEMA 6-20P, factory-installed LCDI cord per UL 484 (applies to all units under 250V)
- Wall Sleeve is NOT included — order separately (e.g., WS900E, WS900QW, or an extra-deep/seacoast variant as needed).
- Exterior Architectural Grille is NOT included — order separately (SGK, AGK, or PGK series).
- Not compatible with 115V circuits
- Not compatible with 265V/hardwire-only applications — that role is filled by the 265V sibling chassis HEC094J, which requires an Amana PTSB4**E sub-base or PTPWHWK4 hard-wire kit with PSHW04A disconnect (sold separately)
- Not a drop-in fit for non-standard sleeve openings
Key Benefits
- EER of 12.8/12.8 (230V/208V) for the cooling side of this configuration
- Built-in dehumidification of 2 pints/hr while cooling
- Fresh air ventilation adjustable from 65-95 CFM for make-up air in tightly sealed rooms
- Single-stage 3.5/3.0 kW electric heat strip sized to the 230V/208V circuit it's wired to
- R-32 refrigerant (lower-GWP alternative to legacy refrigerants)
- Meets or exceeds ASHRAE 90.1 efficiency requirements
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 9,200/9,000 | BTU/h |
| Heating Capacity (230V) | 12,000 | BTU/h |
| Heating Capacity (208V) | 9,900 | BTU/h |
| Electric Heat Strip Size | 3.5/3.0 | kW |
| Heat Stages | 1 | - |
| EER | 12.8/12.8 | BTU/Wh |
| Voltage | 230/208 | V |
| Compressor Amps | 4.1/4.1 | A |
| Compressor Watts | 690/680 | W |
| Total Heater Watts | 3,570/2,935 | W |
| Total Heater Amps | 15.5/14.1 | A |
| MCA | 19.5 | A |
| MOP | 20 | A |
| NEMA Plug Type | 6-20P | - |
| CFM Wet (High/Low) | 290/264 | CFM |
| CFM Dry (High/Low) | 318/318 | CFM |
| Fresh Air Vent | 65-95 | CFM |
| Dehumidification | 2 | pints/hr |
| Net Weight | 102 | lb |
| Shipping Weight | 117 | lb |
| Refrigerant | R-32 | - |
| Wall Sleeve Compatibility | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via NEMA 6-20P plug (factory-installed cord)
- Fits standard 42 in x 16-1/16 in wall sleeve openings
- Not compatible with 115V circuits
- Not compatible with 265V or hardwire-only applications — see 265V sibling chassis HEC094J, which requires the Amana PTSB4**E sub-base or PTPWHWK4 hard-wire kit with PSHW04A disconnect
- Wall Sleeve NOT included — must be purchased separately
- Exterior Architectural Grille NOT included — must be purchased separately
- Not a drop-in replacement for non-standard sleeve openings
| Item | Value |
|---|---|
| Refrigerant Type | R-32 |
| Electrical Compliance | Factory-installed LCDI power cord, UL 484 (units under 250V) |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Voltage Operating Range | 197V min / 253V max (230/208V models) |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to fit the industry-standard 42 in wide x 16-1/16 in high sleeve opening, but you must order a sleeve (such as the WS900E or WS900QW) and exterior grille separately.
What breaker size and plug type does this unit require?
This configuration requires a 20-amp circuit (MOP 20A, MCA 19.5A) and uses a NEMA 6-20P power cord. It is a 230/208V unit and is not compatible with 115V household circuits.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V model and cannot be wired for 265V service. The 265V commercial version of this chassis is the HEC094J, which requires an Amana PTSB4**E sub-base or the PTPWHWK4 hard-wire kit with PSHW04A disconnect switch (sold separately).
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] Installer licensing requirements for warranty validity are not specified in the provided spec files. Refer to the warranty document in the Resources tab for exact terms.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42 in x 16-1/16 in wall sleeve opening used by Amana PTAC sleeves. It is not a drop-in fit for non-standard or custom sleeve openings.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty on the sealed system, per Amana's published warranty badge terms. Exact terms, including any distinction between residential and commercial/hospitality usage limits, are detailed in the warranty PDF. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page. If you have questions about warranty coverage for a commercial hospitality install versus a residential one, ask us before you order — we always reply back.