This is a wall-sleeve air conditioner and electric heater for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room climate control on a standard 230/208V circuit.
The PTC123J25AXXX is a standard-chassis PTAC with electric heat, suited to hospitality rooms, additions, and multi-family units where per-room, self-contained conditioning is preferred over ducted systems. Cooling and heating figures are rated at 230V and 208V per the manufacturer's published performance tables, and the unit meets or exceeds ASHRAE 90.1. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high (rough framing opening approximately 42-1/4 in wide x 16-1/4 in minimum high).
- Voltage: 230/208V. Operating range: minimum 197V / maximum 253V.
- Amperage with electric heat: 11.2/10.1 total amps (230V/208V). MCA 14.1A, MOP 15A.
- Power cord/plug: 6-15P, factory-installed LCDI cord per UL 484 (applies to units under 250V).
- Wall Sleeve is NOT included and is sold separately.
- Exterior Architectural Grille is NOT included and is sold separately.
- Not compatible with 115V circuits.
- Not compatible with 265V circuits. The 265V commercial sibling of this chassis is the PTC124J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A — none of that hardware applies to or is included with this 230/208V unit.
- Not a drop-in replacement for non-standard or custom sleeve openings.
On repeat hospitality installs, the most common callback on a 230/208V PTAC swap isn't the electrical — it's a stained wall below the sleeve six months later. The wall sleeve has to pitch toward the exterior, not sit dead level, or condensate backs up into the drywall instead of draining outside. Set the sleeve with a torpedo level: level side-to-side, but pitched about 1/4 bubble toward the outside wall face, per the framing guidance for this chassis. Confirm the sleeve extends a minimum of 1/4 in beyond the exterior wall face before you seal around it. On multi-unit hospitality properties, document this pitch check on the same punch list you use for NEMA receptacle verification (this unit takes a 6-15P plug, not a 6-20P or 6-30P) — mixing those up on a property-wide retrofit is the second most common callback after drainage.
Key Benefits
- EER of 11.4 (230V) / 11.5 (208V) for verified cooling efficiency.
- 1.7 pints/hour of dehumidification at rated conditions.
- 65 CFM of fresh-air ventilation capability built into the chassis.
- Single-stage 2.5/2.1 kW electric heat strip for supplemental winter heating.
- R-32 refrigerant, per manufacturer catalog notes.
- Meets or exceeds ASHRAE 90.1 efficiency standards.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity (230V/208V) | 11,900/11,700 | BTU/h |
| Heating Capacity (230V) | 8,500 | BTU/h |
| Heating Capacity (208V) | 6,800 | BTU/h |
| Electric Heat Strip Size | 2.5/2.1 | kW |
| Heater Stages | 1 | - |
| Voltage | 230/208 | V |
| Voltage Operating Range | 197 min / 253 max | V |
| Compressor Amps | 5.6/5.6 | A |
| Compressor Watts | 1,040/1,015 | W |
| Total Amps (with heater) | 11.2/10.1 | A |
| Total Watts (with heater) | 2,570/2,115 | W |
| MCA | 14.1 | A |
| MOP | 15 | A |
| NEMA Plug Type | 6-15P | - |
| EER | 11.4/11.5 | - |
| Dehumidification | 1.7 | pints/hr |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 313/285 | CFM |
| Ventilation CFM | 65 | CFM |
| Net Weight | 108 | lb |
| Shipping Weight | 125 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via a 6-15P NEMA plug.
- Fits industry-standard 42 in wide x 16-1/16 in high wall sleeve openings, including the WS900E and WS900QW sleeve models.
- Not compatible with 115V circuits.
- Not compatible with 265V circuits or 265V sub-base/hard-wire accessories — those apply only to the PTC124J commercial sibling.
- Wall Sleeve NOT included — must be ordered separately.
- Exterior Architectural Grille NOT included — must be ordered separately (e.g., SGK, AGK, or PGK grille lines).
- Not a drop-in replacement for non-standard or custom-depth sleeve openings.
| Attribute | Value |
|---|---|
| Refrigerant Type | R-32 |
| Electrical Code Compliance | Factory LCDI power cord per UL 484 (units under 250V) |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to install into an industry-standard 42 in wide x 16-1/16 in high sleeve opening, such as the WS900E or WS900QW.
What breaker size and plug type does this unit require?
This unit ships with a 6-15P power cord and requires an MOP of 15 amps and an MCA of 14.1 amps on a 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V unit and is not rated for 265V circuits. The 265V commercial version of this chassis is the PTC124J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42 in x 16-1/16 in wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] — installer licensing requirements are not specified in the provided data. Refer to the manufacturer warranty document in the Resources tab for exact terms.
Warranty & Registration
This unit carries a manufacturer 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per published warranty badge terms. Exact conditions, including any distinction between residential and commercial/hospitality usage, are detailed in the warranty PDF under the "Resources (System Manuals and Warranty)" Tab above — refer there before assuming coverage terms for a hospitality deployment. We always reply back if you have questions on warranty scope before you order.