Amana | 11,900 BTU | PTAC with Electric Heat | 5.0 kW Electric Heat | 230/208V | PTC123J50CXXX | 30A Power Cord Included | Seacoast Protected

Amana

$1,284.00
(No reviews yet) Write a Review
SKU:
PTC123J50CXXX
Shipping:
Calculated at Checkout
Direct Factory Delivery: Ships directly from wholesale warehouse with scheduled liftgate delivery & tracking.
Adding to cart… The item has been added

This is a wall-sleeve air conditioner with electric heat, built for hotel rooms, apartments, or additions where central ductwork isn't available. This particular configuration adds seacoast-grade corrosion protection, so it's suited to coastal properties dealing with salt-air exposure. It's built for property managers and homeowners who need self-contained, per-room climate control.

The PTC123J50CXXX is a packaged terminal air conditioner with electric heat, built on Amana's PTC chassis and finished with seacoast-grade corrosion protection for coastal and high-salinity environments. It's commonly specified in hospitality properties, multi-family housing, and additions where ductwork isn't practical, and it is designed to meet or exceed ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.

Critical Fit & Power Requirements

  • Wall sleeve opening: Industry-standard 42 in wide x 16-1/16 in high.
  • Voltage: 230/208V (dual-rated; do not confuse with 265V commercial models).
  • Total amps with heater installed: 22.1A (230V) / 20.0A (208V). MCA: 27.6A. MOP: 30A breaker required.
  • NEMA plug type: 6-30P, factory-installed cord with LCDI device per UL 484 (applies to units under 250V).
  • Wall Sleeve is NOT included — order separately (WS900E, WS900QW, or seacoast-rated WS900SC).
  • Exterior Architectural Grille is NOT included — order separately (SGK, AGK, or PGK series).
  • Not compatible with 115V circuits.
  • Not suitable for 265V hardwire-only applications. The 265V commercial sibling of this chassis is the PTC124J, which requires an Amana sub-base (PTSB4**E) or hard-wire kit (PTPWHWK4) with disconnect switch (PSHW04A) — none of this applies to the 230/208V unit described here.
  • Not a drop-in replacement for non-standard or custom sleeve openings.
Pro-Installer Tip:

On seacoast installs, salt-laden air accelerates corrosion at the sleeve-to-wall seam, and standing condensate at that seam is what actually eats through drywall over time — not the salt air itself. Pitch the wall sleeve 1/4 bubble toward the exterior using a torpedo level before securing it, so condensate drains outboard onto the exterior grille rather than pooling against the interior wall cavity. Confirm the sleeve extends a minimum of 1/4 in beyond the outside wall face per the framing diagram. On the electrical side, verify the receptacle is a NEMA 6-30 configuration matched to the unit's 6-30P cord — a mismatched 5-20 or 5-30 receptacle is a common punch-list item on retrofit jobs and will not accept this plug. Document the pitch and receptacle match on the property's PM checklist; this is standard practice under NEC receptacle configuration requirements and helps property managers avoid callback visits for "AC not draining" complaints.

Key Benefits

  • 1.7 pints/hour of dehumidification at rated conditions, useful for humid coastal and hospitality environments.
  • 65 CFM of fresh-air ventilation for make-up air in occupied rooms.
  • Seacoast corrosion protection (Feature Code C) extends service life in salt-air exposure compared to standard-coil chassis.
  • Single-stage 5.0/4.1 kW electric heat delivers 17,100 BTU (230V) / 14,000 BTU (208V) of supplemental heating.
  • R-32 refrigerant, in line with current low-GWP direction for packaged terminal equipment.
  • Meets or exceeds ASHRAE 90.1 efficiency standards.
SpecValueUnit
System TypePTAC with Electric Heat
RefrigerantR-32
Cooling Capacity (230V)11,900BTU/h
Cooling Capacity (208V)11,700BTU/h
EER (230/208V)11.4/11.5
Compressor Amps (230/208V)5.6/5.6A
Compressor Watts (230/208V)1,040/1,015W
MCA - Chassis Without Heater7.4A
CFM Wet High/Low330/245CFM
CFM Dry High/Low313/285CFM
Ventilation CFM65CFM
Dehumidification1.7pints/hr
Net Weight108lb
Shipping Weight125lb
Electric Heat Size (230/208V)5.0/4.1kW
Heat Stages1
Heating Capacity (230V)17,100BTU/h
Heating Capacity (208V)14,000BTU/h
Total Watts w/ Heat (230/208V)5,070/4,160W
Total Amps w/ Heat (230/208V)22.1/20.0A
MCA (with Heater)27.6A
MOP (Max Overcurrent Protection)30A
Voltage230/208V
NEMA Plug Type6-30P
Power CordFactory LCDI cord, UL 484
Corrosion ProtectionSeacoast Protected
Wall Sleeve Dimensions42 x 16-1/16in
Wall Sleeve IncludedNot Included
Exterior Architectural Grille IncludedNot Included

Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.

Compatibility & Fitment

  • Compatible with 230/208V circuits via a factory-installed NEMA 6-30P plug.
  • Fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening.
  • Compatible with Amana WS900E, WS900QW, and seacoast-rated WS900SC sleeve series (sleeve sold separately).
  • Not compatible with 115V circuits.
  • Not suitable for 265V hardwire-only applications — that role is filled by the PTC124J chassis with its own sub-base/hard-wire kit requirements.
  • Wall Sleeve NOT included with this unit.
  • Exterior Architectural Grille NOT included with this unit.
  • Not a drop-in fit for non-standard or custom-depth sleeve openings.
AttributeDetail
Refrigerant TypeR-32
NEC ComplianceFactory power cord includes LCDI device per UL 484 (units under 250V)
Voltage Operating Range230/208V models: minimum 197V / maximum 253V
Overcurrent Protection Standard15A for units without electric heat; this configuration requires 30A MOP per the electric heat performance rating

FAQ

Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit is designed to fit the industry-standard 42 in wide x 16-1/16 in high sleeve opening, but you will need to order a compatible sleeve (such as the WS900E, WS900QW, or the seacoast-rated WS900SC) and exterior grille separately.

What breaker size and plug type does this unit require?
With the 5.0/4.1 kW electric heat installed, this unit has an MCA of 27.6A and requires a 30A circuit breaker (MOP). It ships with a factory-installed NEMA 6-30P power cord for 230/208V service.

Can this be hardwired for 265V commercial applications?
No. This model is a 230/208V unit and is not rated for 265V circuits. The 265V commercial version of this chassis is the PTC124J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit (PTPWHWK4) with disconnect switch (PSHW04A), none of which apply to this 230/208V unit.

Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] - installer licensing requirements for warranty validity are not specified in the source documentation provided. Refer to the warranty PDF in the Resources tab for exact terms.

Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings outside these dimensions.

Warranty & Registration

This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty on the sealed system, per manufacturer badge documentation. Exact terms — including any distinctions between residential and commercial/hospitality usage — are detailed in the warranty PDF under the "Resources (System Manuals and Warranty)" Tab above on this page. Ask us before you order if you need help confirming coverage for a specific commercial application; we always reply back.

Wholesale Specifications & Compliance Guarantee

Official MSSD Direct Distribution Data for Amana Item #PTC123J50CXXX

🚚 Wholesale Freight Shipping Structure

  • Palletized Freight Delivery: Securely packaged and strapped to prevent coil or cabinet transit damage.
  • Liftgate Unloading Included: Every system price reflects complete residential or jobsite liftgate unloading services.
  • Terminal Tracking: Direct carrier tracking with scheduled delivery appointment confirmation.

🛡️ EPA Refrigerant & Safety Compliance

  • Low-GWP Mandate Certified: Compliant with 2025–2026 EPA AIM Act guidelines (R-454B / R-32 next-gen refrigerants).
  • Factory Parts Protection: Full manufacturer warranty integrity preserved via authorized wholesale distribution channels.
  • Factory Pre-Charged: Outdoor condensing units engineered and tested for rated line-set lengths.

📜 Manufacturer Warranty Protection

Authorized Dealer Warranty Protection: All Amana systems purchased through MSSD include full factory manufacturer warranty coverage.

📊 System Engineering & Performance Specifications

Product Model Title Amana | 11,900 BTU | PTAC with Electric Heat | 5.0 kW Electric Heat | 230/208V | PTC123J50CXXX | 30A Power Cord Included | Seacoast Protected
Factory SKU / Part # PTC123J50CXXX
Brand Entity Amana
Wholesale Freight Rate $0.00 (Palletized Liftgate Unloading Included)