This is a wall-sleeve air conditioner and electric heater built for hotel rooms, apartments, additions, or any space without central ductwork. It's a self-contained, per-room climate control unit for property managers and homeowners who need to heat and cool one room at a time.
The PTC153J25AXXX is a 230/208V PTAC chassis with a single-stage 2.5/2.1 kW electric heat strip, built to Amana's standard PTAC platform for hospitality, multifamily, and room-addition applications. Units in this family meet or exceed ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high (WS900E / WS900QW series, standard 14 in depth)
- Voltage: 230/208V — operating range 197V minimum to 253V maximum
- Total amps with heater: 11.2/10.1A (230V/208V); MCA 14.1A; MOP 15A
- Power cord: NEMA 6-15P, factory-installed with LCDI device per UL 484 (applies to all units under 250V)
- Wall Sleeve is sold separately and is NOT included with this unit.
- Exterior Architectural Grille is sold separately and is NOT included.
- Not compatible with 115V circuits
- Not compatible with 265V circuits — this is not the PTC154J 265V commercial sibling chassis, and no 265V sub-base or hard-wire kit applies here
- Not a drop-in fit for non-standard or custom sleeve openings outside 42 in x 16-1/16 in
On 230/208V PTAC replacements, the most common callback is condensate leaking into the drywall below the sleeve, not an electrical fault. This happens when the existing sleeve was reset level instead of pitched. Set the sleeve with a slight pitch toward the outside — about 1/4 bubble on a torpedo level — so condensate drains off the back lip instead of pooling toward the room side. Confirm the pitch with the torpedo level before securing the sleeve to framing, and verify the receptacle matches the NEMA 6-15P cord shipped with this unit; a mismatched receptacle is the second most common return reason on this chassis. Document the circuit ampacity check against NEC receptacle requirements for the property's electrical inspection record — this matters for property management liability, not just code compliance.
Key Benefits
- Single-stage 2.5/2.1 kW electric heat strip delivers 8,500 BTU (230V) or 6,800 BTU (208V) of supplemental heat
- 4.4 pints/hour dehumidification rate for humid-climate guest rooms and additions
- 65 CFM fresh air ventilation option for make-up air in enclosed rooms
- R-32 refrigerant, per Amana catalog specification
- EER of 10.3 (230V) / 10.4 (208V) for standard-efficiency continuous room conditioning
- Meets or exceeds ASHRAE 90.1 efficiency standards
Technical Table
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity (230V/208V) | 14,800 / 14,500 | BTU/h |
| Heating Capacity (230V/208V) | 8,500 / 6,800 | BTU/h |
| Electric Heat Strip Size (230V/208V) | 2.5 / 2.1 | kW |
| Heater Stages | 1 | - |
| EER (230V/208V) | 10.3 / 10.4 | - |
| Voltage | 230/208 | V |
| Compressor Amps (230V/208V) | 7.1 / 7.1 | A |
| Compressor Watts (230V/208V) | 1,435 / 1,430 | W |
| Total Amps with Heater (230V/208V) | 11.2 / 10.1 | A |
| Total Watts with Heater (230V/208V) | 2,570 / 2,115 | W |
| MCA (with heater) | 14.1 | A |
| MOP (with heater) | 15 | A |
| Power Cord / NEMA Plug Type | 6-15P | - |
| CFM Wet (High/Low) | 400 / 314 | CFM |
| CFM Dry (High/Low) | 412 / 390 | CFM |
| Fresh Air Vent CFM | 65 | CFM |
| Dehumidification Rate | 4.4 | pints/hr |
| Net Weight | 113 | lb |
| Shipping Weight | 130 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | 42 x 16-1/16 (industry standard) | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Fits the industry-standard 42 in x 16-1/16 in wall sleeve opening, including the WS900E and WS900QW standard sleeves
- Compatible with 230/208V circuits, 197V–253V operating range, via factory NEMA 6-15P plug
- Not compatible with 115V circuits
- Not compatible with 265V circuits or the 265V sub-base/hard-wire accessories; the 265V commercial version of this chassis is the PTC154J, not this unit
- Wall Sleeve NOT included — order separately (e.g., WS900E, WS900QW, or seacoast/heavy-duty variants as required)
- Exterior Architectural Grille NOT included — order separately (SGK, AGK, or PGK series)
- Not a drop-in replacement for non-standard or custom-depth sleeve openings
Compliance & Environment
| Attribute | Value |
|---|---|
| Refrigerant Type | R-32 |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Power Cord Compliance | LCDI power cord per UL 484 (units under 250V) |
| Overcurrent Protection | 15A MOP, standard fusing/breaker (non-265V unit) |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately from the PTC153J25AXXX chassis. Sleeves are typically installed during construction and are ordered as a separate line item, such as the WS900E standard sleeve.
What breaker size and plug type does this unit require?
This configuration requires a 15-amp maximum overcurrent protection (MOP) device, a minimum circuit ampacity (MCA) of 14.1 amps, and uses a factory-installed NEMA 6-15P power cord on a 230/208V circuit.
Can this be hardwired for 265V commercial applications?
No. This is a 230/208V unit, not a 265V model. It does not use and should not be paired with a 265V sub-base or hard-wire kit. The 265V commercial version of this chassis is the PTC154J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
Refer to the manufacturer warranty document in the Resources tab for exact installation requirements. Field-verified best practice on 230/208V plug-and-play units is a licensed electrician confirm the receptacle and circuit ampacity before energizing the unit.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.
Warranty & Registration
This unit carries a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty, per Amana's published warranty badge terms. Exact coverage details, including any distinction between residential and commercial hospitality usage, are defined in the manufacturer warranty document. Refer to the "Resources (System Manuals and Warranty)" Tab above for the full warranty PDF before installation. Ask us before you order if you're unsure whether your application qualifies as commercial hospitality use — we always reply back.