This is a wall-sleeve air conditioner and electric-heat unit for hotel rooms, apartments, additions, or any space without central ductwork. It's built for property managers and homeowners who need self-contained, per-room climate control on a standard 230/208V circuit.
The PTC153J35AXXX is a 230/208V packaged terminal air conditioner with electric heat, built on the Amana PTC153J chassis. It's a common fit for hospitality renovations, multifamily units, and additions where a self-contained, per-room system replaces central ductwork. This model is R-32 refrigerant and meets or exceeds ASHRAE 90.1. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening: industry-standard 42 in wide x 16-1/16 in high (Amana WS900E / WS900QW sleeve family)
- Voltage: 230/208V — min 197V / max 253V operating range
- Total amps with heater: 15.5/14.1A (230V/208V); MCA 19.5A; MOP 20A
- Power cord: factory-installed NEMA 6-20P plug with LCDI device per UL 484 (applies to all units under 250V)
- Wall Sleeve and Exterior Architectural Grille are sold separately and are NOT included with this unit.
- Not compatible with 115V circuits
- Not compatible with 265V circuits — that voltage requires the commercial PTC154J chassis with a dedicated Amana sub-base or hard-wire kit
- Not a drop-in fit for non-standard or custom sleeve openings outside the 42 in x 16-1/16 in standard
Key Benefits
- 4.4 pints/hr dehumidification at rated conditions
- 65 CFM fresh-air ventilation for make-up air in tightly sealed rooms
- Single-stage 3.5/3.0 kW electric heat strip for supplemental or primary heat in mild climates
- EER of 10.3/10.4 depending on line voltage
- R-32 refrigerant, a lower-GWP option under current catalog specification
- Compressor draws only 7.1A, leaving headroom on the circuit budget when paired with correctly rated wiring
Technical Table
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity (230V) | 14,800 | BTU/h |
| Cooling Capacity (208V) | 14,500 | BTU/h |
| Heating Capacity (230V) | 12,000 | BTU/h |
| Heating Capacity (208V) | 9,900 | BTU/h |
| Electric Heat Strip Size | 3.5/3.0 | kW |
| Heat Stages | 1 | stage |
| Voltage | 230/208 | V |
| Compressor Amps | 7.1/7.1 | A |
| Compressor Watts | 1,435/1,430 | W |
| EER | 10.3/10.4 | — |
| Total Heater Watts | 3,570/2,935 | W |
| Total Amps (with Heater) | 15.5/14.1 | A |
| MCA (with Heater) | 19.5 | A |
| MOP (with Heater) | 20 | A |
| NEMA Plug Type | 6-20P | — |
| CFM Wet (High/Low) | 400/314 | CFM |
| CFM Dry (High/Low) | 412/390 | CFM |
| Ventilation CFM | 65 | CFM |
| Dehumidification | 4.4 | pints/hr |
| Net Weight | 113 | lb |
| Shipping Weight | 130 | lb |
| Wall Sleeve Dimensions | Standard 42 x 16-1/16 | in |
| Wall Sleeve Included | Not Included | — |
| Exterior Architectural Grille Included | Not Included | — |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Compatible with 230/208V circuits via a NEMA 6-20P plug and matching 6-20R receptacle
- Fits the industry-standard 42 in x 16-1/16 in wall sleeve opening (Amana WS900E / WS900QW sleeve family)
- Not compatible with 115V circuits.
- Not compatible with 265V circuits. The 265V commercial sibling is the PTC154J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A — sold separately, not included with either chassis.
- Wall Sleeve NOT included. Order separately.
- Exterior Architectural Grille NOT included. Order separately (SGK, AGK, or PGK series).
- Not a drop-in replacement for non-standard or custom sleeve openings
Compliance & Environment
| Item | Detail |
|---|---|
| Refrigerant Type | R-32 |
| Electrical Standard | Factory-installed LCDI power cord per UL 484 (units under 250V) |
| Efficiency Standard | Meets or exceeds ASHRAE 90.1 |
| Overcurrent Protection (no heater) | 15A, all units without electric heaters |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit fits the industry-standard 42 in x 16-1/16 in sleeve opening (WS900E, WS900QW, or related Amana sleeve models), but you need to order the sleeve and exterior grille separately.
What breaker size and plug type does this unit require?
This configuration (3.5/3.0 kW heat, 230/208V) has an MCA of 19.5A and MOP of 20A, ships with a factory-installed NEMA 6-20P power cord, and requires a dedicated 20A circuit.
Can this be hardwired for 265V commercial applications?
No. This unit is a 230/208V model with a factory power cord, not a 265V chassis. It is not compatible with 265V circuits. The 265V commercial version of this chassis is the PTC154J, which requires an Amana sub-base (PTSB4**E series) or hard-wire kit PTPWHWK4 with disconnect PSHW04A, sold separately.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. This chassis is designed for the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening. It is not a drop-in fit for non-standard or custom sleeve openings.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
Refer to the Resources (System Manuals and Warranty) Tab above for the manufacturer's exact installation and warranty terms. [NEEDS VERIFICATION]
Warranty & Registration
Published badge data for this unit supports a 1-Year Repair/Replace warranty and a 5-Year Parts Limited Warranty. Full terms, including any distinction between residential and commercial hospitality usage, are set out in the manufacturer warranty document. Refer to the "Resources (System Manuals and Warranty)" Tab above on this page for the complete warranty terms before you order — ask us if anything in that document is unclear, and we'll always reply back.