This is a wall-sleeve heat pump for hotel rooms, apartments, or additions where central ductwork isn't available. It's built for property managers and homeowners who need self-contained, per-room cooling and heating in one chassis.
This PTH124J25AXXX pairs the Amana PTH124J heat pump chassis with a factory-installed 2.5 kW electric heat strip for 265V circuits, giving you compressor-driven heating with electric-resistance backup for cold-snap performance. It's suited to hospitality corridors, additions, and multi-family units where a heat pump reduces electric heat runtime compared to strip-heat-only PTAC models. Amana PTAC/PTHP chassis are built to meet or exceed ASHRAE 90.1 efficiency standards. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the "Resources (System Manuals and Warranty)" Tab above on this page.
Critical Fit & Power Requirements
- Wall sleeve opening required: 42 in wide x 16-1/16 in high (standard depth 14 in for WS900E / WS900QW sleeves).
- Voltage: 265V (operating range 239–292V). This is a commercial voltage class — not for 115V or 230/208V circuits.
- Electric heat: 2.5 kW, single-stage, 9.7 total amps, 12.2 MCA, 15A MOP.
- Plug/cord: NEMA 7-20P power cord included with the unit.
- Wall Sleeve NOT included — sold separately.
- Exterior Architectural Grille NOT included — sold separately (SGK, AGK, or PGK grille required).
- Required for 265V operation: Amana sub-base (PTSB4**E series) or hardwire kit PTPWHWK4 with disconnect PSHW04A — neither is included.
- Not compatible with 115V circuits.
- Not compatible with 230/208V circuits — for that voltage, use sibling chassis PTH123J instead.
- Not a drop-in replacement for non-standard or custom sleeve openings.
On 265V hospitality retrofits, techs often reuse an existing 230/208V sub-base because it "looks the same" — it isn't, and the receptacle configuration won't accept the 7-20P plug on this unit correctly, or worse, gets force-fit and arcs under load. Always cross-check the sub-base model plate against a NEMA receptacle chart before energizing the circuit — the PTSB4**E series is the correct family for 265V Amana chassis. This isn't optional: mismatched sub-bases on 265V circuits are a documented cause of overheated terminals and nuisance breaker trips in multi-room hotel wings. Confirm cartridge-style time-delay fuse presence in the sub-base per NEC Article 440 before handing the room back to property management.
Key Benefits
- Heat pump operation (11,500 BTU/h heating) reduces reliance on electric strip heat in moderate outdoor conditions, cutting electric heat runtime versus strip-only PTAC units.
- 1.7 pints/hr dehumidification rate helps manage humidity in guest rooms and multi-family units without a separate dehumidifier.
- Fresh air ventilation adjustable from 65–95 CFM for make-up air in tightly sealed rooms.
- 11.3 EER cooling / 3.3 COP heating efficiency, rated to meet or exceed ASHRAE 90.1.
- R-32 refrigerant chassis.
- Compact 108 lb net weight (125 lb shipping) simplifies sleeve-mounted install and removal for service.
| Spec | Value | Unit |
|---|---|---|
| Cooling Capacity | 12,000 | BTU/h |
| Heating Capacity (Heat Pump) | 11,500 | BTU/h |
| Heating Capacity (265V Electric Heat) | 8,500 | BTU/h |
| Electric Heat Strip Size | 2.5 | kW |
| Electric Heat Stages | 1 | - |
| EER | 11.3 | BTU/(W·h) |
| COP | 3.3 | - |
| Voltage | 265 | V |
| Voltage Operating Range | 239-292 | V |
| Cooling Amps (Compressor Only) | 4.9 | A |
| Heating Amps (Compressor Only) | 4.9 | A |
| Cooling Watts (Compressor Only) | 1,060 | W |
| Heating Watts (Compressor Only) | 1,020 | W |
| Total Watts (With Electric Heat) | 2,570 | W |
| Total Amps (With Electric Heat) | 9.7 | A |
| MCA (With Heater) | 12.2 | A |
| MOP | 15 | A |
| NEMA Plug Type | 7-20P | - |
| CFM Wet (High/Low) | 330/245 | CFM |
| CFM Dry (High/Low) | 324/324 | CFM |
| Fresh Air Ventilation | 65-95 | CFM |
| Dehumidification Rate | 1.7 | pints/hr |
| Net Weight | 108 | lb |
| Shipping Weight | 125 | lb |
| Refrigerant Type | R-32 | - |
| Wall Sleeve Dimensions | 42 x 16-1/16, depth 14 | in |
| Wall Sleeve Included | Not Included | - |
| Exterior Architectural Grille Included | Not Included | - |
Note: See "Resources (System Manuals and Warranty)" Tab above for full specifications.
Compatibility & Fitment
- Fits industry-standard 42 in wide x 16-1/16 in high wall sleeve openings (rough opening approx. 42-1/4 in wide x 16-1/4 in minimum high).
- Compatible with 265V commercial electrical circuits (239–292V operating range) via NEMA 7-20P plug, when paired with the required Amana PTSB4**E sub-base or PTPWHWK4 hardwire kit with PSHW04A disconnect.
- Not compatible with 115V household circuits.
- Not compatible with 230/208V circuits — the 230/208V version of this chassis is sold as model PTH123J.
- Wall sleeve NOT included — order separately (e.g., WS900E, WS900QW, or seacoast/deep variants as needed).
- Exterior architectural grille NOT included — order separately (SGK, AGK, or PGK series).
- Not a drop-in fit for custom or non-standard sleeve depths/openings.
| Compliance Item | Value |
|---|---|
| Refrigerant Type | R-32 |
| ASHRAE Compliance | Meets or exceeds ASHRAE 90.1 |
| Overcurrent Protection (265V, with heater) | Cartridge-style time-delay fuses, factory-installed, 15A MOP |
| Power Cord Compliance | NEMA 7-20P; 265V units do not use the LCDI cord (LCDI applies only to units under 250V per UL 484) |
FAQ
Is the wall sleeve included with this unit?
No. The wall sleeve is sold separately. This unit fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve opening (WS900E / WS900QW standard depth 14 in).
What breaker size and plug type does this unit require?
With the 2.5 kW electric heat installed, this configuration has an MCA of 12.2A and a maximum overcurrent protection (MOP) rating of 15A. It uses a NEMA 7-20P plug at 265V.
Can this be hardwired for 265V commercial applications?
Yes. This is a 265V unit and must be installed with an Amana brand sub-base (PTSB4**E series) or hardwire kit PTPWHWK4 with disconnect switch PSHW04A. Neither is included with the unit.
Does this require a licensed electrician or HVAC professional to install and keep the warranty valid?
[NEEDS VERIFICATION] Installer licensing requirements are not specified in the provided data. Refer to the manufacturer warranty document in the Resources tab for installation conditions affecting warranty validity.
Will this fit a standard 42-inch by 16-inch wall sleeve opening?
Yes. The PTH124J chassis fits the industry-standard 42 in wide x 16-1/16 in high wall sleeve. It is not a drop-in fit for non-standard or custom sleeve openings.
Warranty & Registration
Manufacturer-backed warranty for this Amana PTHP chassis includes 1-Year Repair/Replace coverage and a 5-Year Parts Limited Warranty on the sealed system. Commercial hospitality installations and residential installations may carry different usage terms and registration requirements — refer to the full warranty PDF in the "Resources (System Manuals and Warranty)" Tab above for exact conditions, exclusions, and registration steps before you order.